COMBI419

COMBI419

COMBI419

Product catalog summary
Description
The COMBI419 and COMBI420 are innovative meters designed for comprehensive safety testing of electrical installations, adhering to standards like VDE0100 and BS7671. They measure environmental parameters, leakage currents, and power factors in single-phase systems. The device features a user-friendly multilanguage menu and supports remote testing via an optional probe (PR400). It includes an AUTO function for sequential safety tests and has a robust design suitable for field use. Measurements can be stored and transferred to a PC.

Main Features
- Contextual help for each function
- Remote probe compatibility
- General menu for quick test selection
- Automatic safety tests through a single outlet
- High-resolution loop impedance measurements with optional accessories

Models and Features
The COMBI419 model includes tests for continuity, insulation resistance, RCD tripping time and current, contact voltage, loop impedance, prospective short circuit current, global earth resistance, phase sequence, and leakage current. It supports automatic tests and remote probe activation.

Standard Accessories
- Cable with Shuko plug
- Set of cables and alligator clips
- Carrying bag
- Calibration Certificate
- Instruction manual and quick reference guide

Optional Accessories
- Leakage current clamp
- Windows software with optical/USB cable
- High-resolution loop impedance accessory
- Remote probe for test activation

Standards
The device complies with CE mark, EN 61557 series, EN 61010, EN 61326 EMC standards, and others.

Electrical Specifications
Accuracy is specified at 23°C ± 5°C with humidity <60%RH. The document details specifications for continuity tests, RCD tripping time and current, insulation resistance, contact voltage, loop impedance, global earth resistance, phase sequence, and leakage current.

General Specifications
- Dimensions: 240 x 160 x 70 mm
- Weight: 1.2 kg
- Protection degree: IP50
- Memory: >600 locations
- Display: Graphic LCD with backlight
- Power Supply: 6x 1.5V batteries
- Environmental conditions: Operating temperature 0°C ~ 40°C, humidity <80%RH
- Compliance with EMC and LVD guidelines

Contact Information
BST Caltek Industrial Ltd., Hong Kong. Email: [email protected], Tel: (852) 2401-1222
See more

Catalog excerpts

COMBI419-1

HT COMBI419 Innovative meter designed to perform all safety test

 Open the catalog to page 1
COMBI419-2

Description COMBI419 and COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance to recently standards (VDE0100, BS7671 and so on, measure and save results of [environmental parameters (illuminanance, temperature, sound level) 420], leakage currents and [active power, harmonics, power factor measurements on single phase systems 420]. The meter it's very easy to use and have a wide number of internal features which are selectable by using the multilanguage menu. The instrument permits, moreover, to start principal measures by using...

 Open the catalog to page 2
COMBI419-3

quickly selection of available test AUTOMATIC function to perform all safety tests through loop impedance measurements High resolution (0.1 mQ) loop impedance

 Open the catalog to page 3
COMBI419-4

MODELS AND FEATURES Measurements Continuity test on protective conductor with 200mA Insulation resistance 50-100-250-500-1000VDC RCDs tripping time and current (general and selective, AC and A types) 10-30-100-300-500mA Contact voltage Ut Loop impedance P-N, P-P, P-PE Loop impedance P-N, P-P, P-PE with high resolution (0.1m ) with IMP57 optional accessory Prospective short circuit current Global earth resistance Ra without RCDs tripping Phase sequence Leakage current (with HT96U optional accessory) AUTOMATIC test (Ra, RCD time, Insulation) directly on outlet Using optional remote probe (PR400)...

 Open the catalog to page 4
COMBI419-6

ELECTRICAL SPECIFICATIONS Accuracy is indicated as ± (% rdgs + no. of dgt) at 23°C ± 5° con relative humidity <60%RH C, (*) Technical specification can be modified without notice Continuity test on protective conductors (*) after cable calibration which eliminates the cable resistance >200mA DC per R Test current CAT III 240V to Ground CAT III 415V between inputs (calibration included) current measurement resolution: 1mA Open leads voltage RCDs tripping time Resolution ms CAT III 240V to Ground CAT III 415V between inputs Nominal tripping current Phase-ground voltage Voltage contact limits RCDs...

 Open the catalog to page 6
COMBI419-7

Insulation resistance (DC voltage) V 1000 ~ 1999 Open leads voltage Test voltage 1.1 x nominal test voltage voltage measurement resolution:1V Short circuit current Nominal current the instrument returns an error message while detecting an input voltage >30V CAT III 240V to Ground, CAT III 415V between inputs CAT III 240V to Ground, CAT III 415V between inputs Loop impedance P-P, P-N, P-PE Range ( ) 0.01 ~ 9.99 Maximum peak current Test voltage Category of measure range (with option accessory IMP57) 3.65A @ 127V; 6.64A @ 230V; 11.5A @ 400V 100÷265V (phase-neutral) / 100÷460V (phase-phase); 50Hz...

 Open the catalog to page 7
COMBI419-8

Global Earth Resistance RA without tripping the RCD Range ( ) Test voltage CAT III 240V to Ground, CAT III 415V between inputs Phase sequence with 1 or 2 wires Range (V) correct phase sequence wrong phase sequence phase coincidence Category of measure CAT III 240V to Ground CAT III 415V between inputs The instrument detects the phase sequence by touching the hot wire. The detection is not performed on insulated cables Frequency Leakage current AC TRMS (amperometric input) mV Frequency range CAT I 30V to Ground and between inputs GENERAL SPECIFICATIONS MECHANICAL FEATURES Dimensions Weight (batteries...

 Open the catalog to page 8
COMBI419-9

GE0416-Low batteries indications 'L^JJT Symbol at display POWER SUPPLY Battery life > 600 measurements (without using the timer) ENVIRONMENTAL CONDITIONS Reference temperature of calibration (23 °C ± 5°C) Storage temperature (batteries not included) -10°C ~ 60 °C GENERAL REFERENCE STANDARDS EMC 89/336/EEC guideline amended with 93/68/EEC (IEC61326) Insulation class 2 (double insulation) Overvoltage category of the voltage inputs (installation/measurement) CAT III 240V to ground, 415V between inputs Overvoltage category of the AUX input Safety of measuring instruments IEC / EN61010-1 Product type...

 Open the catalog to page 9

Archived catalogs

  1. BT501

    2  Pages

  2. BT521

    2  Pages

  3. BT511

    5  Pages

  4. BT701

    3  Pages

  5. BT513

    5  Pages

  6. BT512

    5  Pages

  7. M73

    9  Pages

  8. BT514

    5  Pages

  9. COMBI420

    11  Pages

  10. PSM2/2A

    4  Pages

  11. GSC53N

    10  Pages

  12. BT502

    2  Pages

  13. Scope Meter

    4  Pages