GCR-N? Reverse Buckling Disk
1Pages

{{requestButtons}}

Catalog excerpts

GCR-N? Reverse Buckling Disk - 1

Sanitary Reverse Buckling Disks BSBSystems.com | BSB.ie Visit our website for the most complete, up-to-date information GCR-NTM and NovAseptic® NA-Connect Disk Holder The GCR-N and GCR-NS™ reverse buckling disks are installed in NovAseptic® NA-Connect holders, which permit flush mounting of the disk with the interior wall of the vessel and are easy to clean and sterilize. The GCR-N design uses Saf™ technology offering a wide range of burst pressures for sanitary / aseptic applications in the pharmaceutical, biotechnology and food industries. Liners are available in all sizes as optional on the process side of the disk. FEP or PFA are generally used. Temperature range FEP -40°F to 400°F (-40°C to 204°C) PFA -40°F to 500°F (-40°C to 260°C) Size Minimum burst pressure for lined disks at 72°F (22°C) • One disk design for gas and liquid service • Flush mounting with vessel wall • Fail-safe design: damage safety ratio < 1 • Low to high burst pressures • Ideal for CIP / SIP service* • Installed with integral sanitary /aseptic gaskets • 8-16 micro-inch typical disk surface finish • Minimum dead space between process fluid and the disk • Suitable for operating pressures up to 90% of marked burst pressure** or 95% of the specified minimum burst pressure (CEN standard pending) • Designed for non-fragmentation • Standard manufacturing design range, 0%, optional -5%, -10% • Withstands full vacuum at all burst pressures • SAS™ (sanitary alert sensor) with leak sensing option available • Integral burst disk sensor option • Worldwide patents pending *Clean / steam in place **At marked burst pressures of 40 psig (2.76barg) and below, the recommended maximum operating pressure is 90% of the marked burst pressure, less 2 psig (0.138barg) tolerance GCR-N Disk Specification Minimum / maximum burst pressure at 72°F (22°C) psig (barg) Burst pressure Nominal disk size Inlet height NAconnect holder type NA-connect design pressure is 101 psig (7barg) at 302°F (150°C) Other burst pressures may be available; Consult BS&B NA-Connect® is a registered trademark of NovAseptic Equipment AB NovAseptic is a registered trademark of Millipore Corporation. Disk size KR  values MNFA (minimum net NAC-38 and NAC-51 holders relief area), and NRA (net relief area values Nuts KR values applicable with or without Locking ring (2 integral burst sensors2 - Use MNFA  when sizing in parts) according to ASME code, para Ferrule UG-127(a)(2)(a) - Use NRA cm2 (net relief / area) when sizing according to European TM standards GCR-N rupture disk The KR values indicated are for gas service. The GCR-N disks Bolt Welding flange have been performance tested inlet for both gas and liquid service; contact BS&B for liquid service KR values. CE marking of bursting disks is available. Products, specifications and all data in this literature are subject to change without notice. Questions regarding product selection and specifications for specific applications should be directed to BS&B. All sales are subject to the BS&B companies’ standard terms and conditions of sale. Nothing herein should be construed as a warranty of merchantability or fitness for a particular purpose. Limerick, Ireland T: +353 61 484700 F: +353 61 227987 E: sales@bsb.ie © 2014 BS&B Safety Systems, L.L.C Rev June 2014

Open the catalog to page 1

All BS&B SAFETY SYSTEMS catalogs and technical brochures

  1. Type D

    8 Pages

  2. Rupture Disk

    12 Pages

  3. SmartSystem

    4 Pages

  4. MRB series

    1 Pages

  5. AVB

    2 Pages

  6. Nu-Saf Plus

    8 Pages

  7. Type B

    8 Pages