Catalog excerpts
Pin & Sleeve Devices IEC Configurations and Ratings IEC Configurations Make Safe Connections As Easy As Clockwork Female Grounding Sleeve The housing keyway is always located at the 6 o’clock position on all female devices and is clearly visible to the user. Female Housing Keyway 4-Pole 5-Wire 3-Pole 4-Wire 125/250V AC 440-460V (60HZ) 2-Pole 3-Wire 11 12 1 10 3ØY 120/208V 3Ø 250V 380415V 2 9 3 380V 50Hz 250V DC 440V 60Hz 4 8 7 6 480V AC 250V AC 5 125V AC 277V AC 3Ø480V AC 3Ø 600V AC 380-415V AC 3ØY 277/ 480V 3ØY 347/600V 200/346V AC 240/415V AC IEC Pin & Sleeve device housings are color...
Open the catalog to page 2IEC Catalog Numbering System Bryant's Pin & Sleeve line safeguards against mismating devices of different amperage and voltage ratings. Conformance with IEC 60309-1 and IEC 60309-2 international standards results in a singly-rated, non-interchangeable configuration for each amperage/voltage type. A housing size has been specified for each amperage rating. The voltage rating can be identified by the clock position of the female grounding sleeve relative to the housing keyway. With the keyway always positioned at 6 o'clock, the female grounding sleeve is located at a specific clock position...
Open the catalog to page 3Watertight Plug Product Features Devices conform to IEC 60309-1 and 60309-2 International Standards for singly-rated, non-interchangeable configurations for each amperage/voltage type. Prevents mismating of devices with different voltages. Gland nut and body have opposing thread profiles to prevent pull-out and reduce wear (available in most promotes safe handling Toughened nylon housing protects against cracking, chemical abrasion Neoprene sealing glands provide a watertight seal Cord clamp screws fasten into threaded steel nuts to prevent strip-out Solid brass pins provide superior...
Open the catalog to page 4Pin & Sleeve Devices IP67 Suitability Watertight Connector Product Features Spring-loaded gasketed cover Self-adjusting contacts provide accurate pin insertion; producing self-cleaning effect as pin is inserted and withdrawn from sleeve High temperature contact carrier Radial rib exterior 460C7W Phase contacts are recessed in deep insulated chambers to minimize arcing Terminal screws are backed out for easy assembly Ground contact in forward position ensures first make, last break; neutral contact connects next, then phase contacts Bryant’s exclusive 60A and 100A contact design features a...
Open the catalog to page 5Watertight; 20, 30 and 60 Amp Ordering Information NORTH AMERICAN RATINGS Watertight Devices Note: 'Back boxes for: 20 and 30 amp receptacles require AP2030 adapter plate (page K-10) ordered separately. Also see direct mounting back box DM20301 (page K-11). 60 amp receptacles require AP60 adapter plate ordered separately (page K-10). Also see direct mounting back box DM602 (page K-11). "For use with plugs and inlets. Provides watertight protection. Specifications are subject to change without notice.
Open the catalog to page 6Watertight; 100 Amp and International Ordering Information suffinty NORTH AMERICAN RATINGS Note: 'Back boxes for 100 amp receptacles require AP100 adapter plate ordered separately (page K-10). "For use with plugs and inlets. Provides watertight protection. INTERNATIONAL RATINGS*** Note: 'Back boxes for: 16 and 32 amp receptacles require AP2030 adapter plate ordered separately (page K-10). Also see direct mounting back box DM20301 (page K-11). 63 amp receptacles require AP60 adapter plate ordered separately (page K-10). Also see direct mounting back box DM602 (page K-11). 125 amp receptacles...
Open the catalog to page 7Splashproof Devices Product Features When devices are exposed to limited splashing of water or other liquids, Bryant offers splashproof devices in six of the most popular international voltage and amperage ratings. These devices are ideally suited for OEM manufacturers, who build equipment for export overseas. Devices are required to withstand impact from handling and fluctuations in heat and cold without interruption of performance. The Splashproof series is ideal for this application. Available in 16 and 32A, splashproof devices meet IEC 60309-1 and IEC 60309-2 standards, resulting in...
Open the catalog to page 8Splashproof; 16 and 32 Amp International Ordering Information suitability INTERNATIONAL RATINGS Note: 'Requires AP2030 adapter plate, ordered separately (page K-10). Also see direct mounting back box DM20301 (page K-11). SPLASHPROOF PLUG SPLASHPROOF CONNECTOR SPLASHPROOF RECEPTACLE Specifications are subject to change without notice.
Open the catalog to page 9Accessories; Back Boxes and Plates To complete your installation, Bryant offers a full line of back boxes, adapter plates and closure caps. Pin & Sleeve accessories feature the heavy-duty construction and durability you require for reliable performance in harsh Back Boxes Bryant offers a complete line of angled and feed-thru back boxes for mounting receptacles and inlets. Each back box features heavy-duty cast aluminum construction with a durable enamel finish. Adapter plate required to mount receptacles and inlets to back boxes - order separately. See ordering information below. Note:...
Open the catalog to page 10Accessories; Back Boxes and Closure Caps Direct Mounting Back Boxes 15° angle cast aluminum back boxes be mounted directly to box without adapter plate. Closure Caps Closure caps provide a watertight seal for male plugs and flanged inlets when not mated. Thick wall, heavy-duty thermoplastic construction protects male pins from contaminants and abuse. Ideal for applications in wash down areas or when equipment is being GUIDE TO WATERTIGHT APPLICATIONS Specifications are subject to change without notice.
Open the catalog to page 11Unfused Mechanical Interlocks Product Features Heavy-Duty Construction For Demanding Applications Bryant's rugged mechanical interlocks combine the safety of a disconnect switch and IEC 309 Pin & Sleeve receptacle in one compact non-metallic enclosure. Designed to meet the National Electrical Code requirements for a separate disconnect means within sight of all motor loads, the enclosures provide ON/OFF switched control of a plug connected load. The interlocking feature prevents the plug from being disconnected while the receptacle is energized. The switch cannot be turned ON until the plug...
Open the catalog to page 12All Bryant catalogs and technical brochures
-
Network Wiring
1 Pages
-
Locking Devices
1 Pages
-
Full Line Catalog
300 Pages
-
Tamper Resistant Receptacles
2 Pages
-
Surge Protection Devices
2 Pages
-
Pre-Wired Receptacles
2 Pages
-
Power Disruption Solutions
12 Pages
-
Pool Pump Receptacle Kit
2 Pages
-
Occupancy Sensors
16 Pages
-
Heavy Duty Straight Blade
2 Pages
-
Healthcare Solutions
12 Pages
-
Ground Fault Sensing Module
2 Pages
-
Ground Fault Receptacles
2 Pages
-
COBRA® Plugs and Connectors
2 Pages
-
Bryant Metal Raceway
12 Pages
-
BRYANT Facility Audit
6 Pages
-
Duplex Surge Receptacles
2 Pages
-
BRYANT® Wiring Devices
2 Pages
-
Bryant Motion Switch
2 Pages
-
AC Industrial Switches
2 Pages
-
50 Amp Locking Devices
2 Pages
-
Full Line Catalog
388 Pages
-
G000 Rotork Product Portfolio
24 Pages
-
Network Wiring- Section P
36 Pages
-
Wallplates
26 Pages
-
Delivery Systems
14 Pages
-
Wire Management Products
36 Pages
-
Locking Devices
48 Pages
-
Motor Control Products
14 Pages
-
Lighting Controls
14 Pages
-
AC Switches
20 Pages
-
Decorator Products
20 Pages
-
Ground Fault Devices
16 Pages
-
Straight Blade Devices
52 Pages