Ground Fault Receptacles - 1

Ground Fault Receptacles with LED Provide GFCI Functionality Indication. The LED with a GFCI message! The Bryant LED indicates the ability of the GFCI to perform its “ground fault protection” function when tested. There has been a common industry indicator for the past 30 years that has been recognized when GFCI receptacles are tested. If a ground fault receptacle were unable to provide protection when the test button is pressed, the reset button would remain recessed. With the reset button not “popping out”, it signifies that GFCI protection was no longer available. Today, the new Bryant GFCI receptacle provides additional helpful information regarding protection. When tested, a rapid flashing red LED will be activated if the ability of the GFCI to provide protection is no longer present. Additional Features • Miswire Protection: If the line and load are mis-wired, there will be no power at both the face and downstream. In addition, the unit will not be able to reset. • The LED “end of life” indicator. • GFCI Protection Indicator: Upon test, flashing red LED indicates discontinuation of GFCI protection. • Compact size of unit allows for additional wiring room for quick and easy wiring. Knowledge of code requirements and safety considerations are essential for determining what applications require ground fault protection. Many GFCI requirements are stated in the National Electric Code (Article 210.8) including bathroom, unfinished basements, kitchen and outdoor outlets. In addition, pools, hot tubs, spas, swimming pool equipment and garages all require GFCI protection. Consult NEC for additional locations requiring GFCI protection. • Meets UL943 surge testing (3kA, 6kV) without having to resort to an inoperative power condition that denies power and locks out the end user.

Open the catalog to page 1
Ground Fault Receptacles - 2

Ground Fault Receptacles with LED Catalog Offering Product Specifications Electrical Commercial Specification Grade Trip Level Trip Time Voltage Range Office White Note: 50 piece bulk pack, use suffix “BULK” ie: (GF52LBULK) Environmental Flammability Operating Temperature Maximum Humidity Product Listings • UL 943 Class A for GFCI • UL 498 Receptacles • CSA Certified to 22.2 No. 144 • Maximum Humidity 95% Color Brown Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of the possibility of power...

Open the catalog to page 2

All Bryant catalogs and technical brochures

  1. Network Wiring

    36 Pages

  2. Wallplates

    26 Pages

  3. AC Switches

    20 Pages