PRISMIC® A32 Excitation Controller PRODUCT SPECIFICATION Introduction The BRUSH PRISMIC® A32 excitation controller or automatic voltage regulator (AVR) incorporates all the features usually required for control of a Brushless generator equipped with a single phase permanent magnet generator (PMG) pilot exciter. High integrity dual redundant excitation system in a single 19 inch enclosure Built in power system stabiliser Negative forcing of exciter field voltage SCADA/DCS communications using Ethernet EGD or RS232/RS485 Modbus protocol Conforms to CE directives and CSA/UL approval pending Compatible connections with earlier BRUSH products for easy upgrades Automatic tracking between channels in all modes Built in colour TFT operator interface Including PC Human Machine Interface (HMI) software for advanced maintenance diagnostics and downloading of data Digital (discrete) outputs for remote status indication Analogue input signal for special applications Modes of operation include generator terminal voltage control, power factor control, VAr control and offload VArs Monitoring of rotating rectifier health and diode failure indication The following limiters are included: PRISMIC® A32 Excitation Controller The A32 includes two fully featured independent controllers and two independent power circuits within a single 6U 19 inch enclosure. Each controller acts as a hot standby for the other and each channel is independently controlled with automatic tracking included to enable smooth transfer from one controller to the other. The A32 is one of the first excitation controllers to provide features such as an integrated power system stabiliser, a colour TFT display and Ethernet connectivity integrated into a single standard 19 inch rack package. These features also use already proven BRUSH technologies that have been developed for other BRUSH products and which are now in operational service with many large generating sets. - Over excitation limiter - Under excitation limiter - Over flux limiter - Fast acting field current limiter - Stator current limiter • Automatic switching to standby initiated by the following conditions: - Over voltage monitor triggered - Under voltage monitor triggered - Over excitation monitor triggered - Under excitation monitor triggered - Over flux monitor triggered - Voltage sensing error Rotor earth fault detector input included eliminating the need for separate unit Auxiliary power supply input allows easy setting of unit without PMG supply present • Limiter and Monitor Settings Speed detector included eliminating the need for separate speed switch unit Soft start for controlled application of excitation

Open the catalog to page 1
PRISMIC A32 - 2

Max continuous output current: Max 10 second output current: Excitation supply voltage: Supply frequency: Nominal sensing voltage: Voltage sensing phases: Nominal generator frequency: Current transformer input nominal: Current transformer input burden: Load taken by sensing inputs: Maximum field voltage for forcing: Minimum field voltage: Voltage adjustment range: Auxiliary power supply: Operating temperature range: Storage temperature range: * Depending upon regulation of excitation 3 phase or single phase 70% of available excitation supply voltage* -70% of available excitation supply...

Open the catalog to page 2

All Brush HMA catalogs and technical brochures

  1. Transformers

    1 Pages

  2. Tapchangers

    2 Pages

  3. PRISMIC A12

    2 Pages

  4. MAVR upgrade

    4 Pages

  5. PRISMIC A30

    2 Pages

  6. PRISMIC T20

    2 Pages

  7. PRISMIC R10

    2 Pages

  8. PRISMIC A50

    4 Pages

  9. PRISMIC PMS

    11 Pages

  10. AC Traction

    2 Pages

Archived catalogs