Specifications
  • Rated Voltage: 38 kV
  • Short Circuit Making Current: 25 kA
  • Impulse Voltage Withstand: 170 kV
  • Power Frequency Withstand (Wet & Dry): 80 kV
  • Control Voltage: 110 V dc (48 & 220 Optional)
  • Rated Frequency: 50/60 Hz
  • Rated 3 sec Short-Time Current: 25 kA
  • Peak Short Circuit Making Current: 63 kA
  • Peak Withstand Current: 63 kA
  • Internal Arc (EATS 41-36): 31.5 kA 1sec
  • Fault Making Time: 190 ms
  • Endurance at 25kA: 50 makes
  • Temperature Range: -50 to +50 ˚C
  • Weight: 500 Kg
Product Overview

The Fault Thrower is part of the Horizon family of products, designed to introduce a phase to earth fault to ensure remote end tripping of a circuit breaker when pilot wires are unavailable. It is particularly useful for transformer feeders to enable remote breaker response to local fault detecting relays.

Key Benefits
  • Utilizes a single phase vacuum interrupter driven by a magnetic actuator for fault initiation.
  • Housed in an aluminium tank with SF6 gas providing dielectric insulation.
  • System connection via separable connector or open terminal bushing.
  • Manual release available within the control cubicle under the tank.
  • Fault is directed through the aluminium tank with two earth points for safe earthing and fault path provision.
Contact Information

BRUSH Switchgear Division: Unit 3, Blackwood Business Park, Newport Road, Blackwood, South Wales NP12 2XH United Kingdom
T: +44 (0) 1495 223 001
Website: www.brush.eu

See more

Catalog excerpts

Fault Thrower-1

BRUSH TRUST. WELL EARNED. Fault Thrower 38kV 25kA Single Phase to Earth Fault Making Switch Part of our Horizon family of products, the Fault Thrower provides a means of deliberately introducing a phase to earth fault in order to ensure remote end tripping of a circuit breaker, assuming pilot wires are not available for intertripping. The need to operate the remote circuit breaker can be due to equipment faults, such as thermal protection or low level fault currents that cannot be detected by the remote protection. Key Benefits to Retrofit • Superior, proven technology using a single phase vacuum interrupter driven by a magnetic actuator for fault initiation • The switch is housed in an aluminium tank, dielectric insulation is provided by SF6 gas • Connection to the system is achieved by either a separable connector or open terminal bushing A typical application is with transformer feeders to enable the remote feeder breaker to respond to the transformer local fault detecting relays, such as Buchholz protection, local earth fault protection etc. • Manual release of the switch is available within the control cubicle housed under the tank • The fault is 'thrown' through the aluminium tank, two earth points are provided for safely earthing the equipment steel work and to provide a fault path BRUSH Switchgear Division: Unit 3, Blackwood Business Park, Newport Road, Blackwood, South Wales NP12 2XH United Kingdom T: +44 (0) 1495 223 001