Introduction
BRUSH DG salient pole rotor, air-cooled generators are widely used in various applications including public utilities, cogeneration, CHP, industrial, and offshore. They are compatible with both steam and gas turbines, with BRUSH having extensive experience in gas turbine applications.

Stator
The stator frame is a robust structure made from mild steel, designed to handle mechanical stresses. It features a core built from high silicon content electrical steel, with radial ventilation ducts for cooling. The stator winding uses a high-performance class F insulation system.

Rotor
The rotor is crafted from high-quality alloy steel, featuring copper strip coils insulated with aramide and epoxy resin. The rotor undergoes rigorous testing to ensure quality and performance.

Bearings
Main bearings are hydrodynamic cylindrical bearings with forced lubrication. Thrust bearings are available for specific conditions.

Cooling
Cooling is achieved through air, either in open or closed circuit configurations. The system is designed to cool the windings uniformly.

Excitation System
BRUSH DG turbogenerators use brushless excitation systems, eliminating the need for commutators and sliprings.

Research & Development
The R&D department focuses on improving processes, materials, and design methods using finite element analysis for optimization.

Features and Specifications
BRUSH DG turbogenerators offer simple foundation design, minimal components, factory testing, heavy-duty design, high efficiency, low noise, and compliance with international standards. They support voltages up to 15kV and speeds of 1500 or 1800 rev/min, with outputs ranging from 10 to 65MVA.

International Sales and Support
BRUSH provides global support with locations in the USA, UAE, Netherlands, and Malaysia.
See more

Catalog excerpts

DG 4-Pole Turbogenerators-1

TURBOGENERATORS TURBOGENERATORS DG 4-Pole Turbogenerators Equipment supplied to over 130 countries. Over 120 years of electrical experience. www.brush.eu

 Open the catalog to page 1
DG 4-Pole Turbogenerators-2

TURBOGENERATORS 21MW gas turbine driven generator with a multi-stage air inlet filter system. Introduction Packaged generator with closed circuit cooling through a top-mounted air-to-air heat exchanger. BRUSH DG salient pole rotor, air cooled generators are extensively used in public utility, cogeneration, CHP, industrial and offshore applications. These generators are designed to be driven by both steam turbines and gas turbines, with extensive operational experience of both applications. BRUSH has more experience of the use of gas turbines than any other generator manufacturer in the world...

 Open the catalog to page 2
DG 4-Pole Turbogenerators-3

Rotor The rotor of a BRUSH DG turbogenerator is manufactured from a one-piece forging of high quality alloy steel, which is de-gassed, vacuum poured and stress relieved to obtain a uniform material which has excellent tensile properties. unsuitably contaminated environments may necessitate the use of a closed air circuit machine, where the hot exhaust air is cooled by a secondary coolant before being returned to the inlet. The secondary coolant is usually air or water. Excitation System The four individual coils of the rotor winding are built up from copper strips, brazed to each other by means...

 Open the catalog to page 3
DG 4-Pole Turbogenerators-4

TURBOGENERATORS Features Specification The BRUSH DG range of turbogenerators has the following features: • • • • • • • • Simple foundation design for economic and speedy civil work. Minimum number of individual power station components, offering substantial savings on expensive site time. All units are fully factory tested, reducing commissioning to proving interconnections and combined turbine/generator testing. Heavy duty design, with modular construction giving a fine balance between flexibility and standardisation of components for fast economic construction. Fully developed system readily...

 Open the catalog to page 4

Archived catalogs

  1. TAPCHANGER

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.