
Catalog excerpts

SCION SQ Series GC-MS The Gas Chromatographers’ Detector Innovation with Integrity
Open the catalog to page 1
Introducing the SCION SQ™ GC-MS Bruker’s long tradition of innovation and product reliability have combined to create a new industry standard for gas chromatography single quadrupole mass detection – the SCION SQ series. By designing the GC-MS systems to exceed the most critical performance and reliability needs of GC users, Bruker has delivered systems that are especially for, and all about, the ultimate success of the GC users. The SCION SQ Select, Prime, and Premium models are designed to meet many important user specific requirements – reliable performance, ease-of-use and simple...
Open the catalog to page 2
• Enhanced Library Searching through Cleaner El Spectra The SCION SQ models are designed to analyze thousands of samples from complex matrices. With an upper mass limit of m/z 1200, they are exceptionally capable of handling almost any GC application. The innovative lens-free design, combined with the robustness of the axial ion source, delivers unmatched stability and ultra-high sensitivity on a routine basis. ■ One-click search of multiple spectral ■ User-created spectral libraries and full support of spectral libraries such as NIST, Wiley, and Maurer/Pfleger/ ■ Adjustable spectral search...
Open the catalog to page 3
Why Choose the SCION SQ? The SCION SQ series delivers exceptional performance for a single quadrupole mass spectrometer: a robust axial ion source, ultra-high sensitivity, cleaner spectra, and virtually-zero neutral noise. The series includes the SQ Select, Prime, and Premium GC-MS models. For routine EI-only applications, the SCION SQ Select delivers the best value. It comes with an industry leading 400 L/s high-capacity turbo pump that enables fast pump-down time for quick maintenance, and the use of high carrier gas flow for fast GC separations. The EI-only SCION SQ Prime model comes...
Open the catalog to page 4
Linearity, Sensitivity, and Spectral Matching Using the SCION SQ for US EPA Methods TIC chromatogram of a 5 mL water sample containing 84 VOCs at 10 µg/L (ppb) by US EPA Method 524.3 (A) Excellent linearity of Tetrachloroethylene from 0.1 to 40 ppb with the purge-and-trap, (B) good sensitivity, (C) high quality spectra, (D) down to 0.1 ppb level and showing good match to the NIST library.
Open the catalog to page 5
Gas Chromatographs An Infusion of Innovation with a Legacy of Reliability The GC is a key part to the reliability, robustness, and sensitivity of any GC-MS analysis. Bruker’s philosophy of innovation is highlighted by the introduction of two new GCs built to support the ultrasensitive SCION SQ. The compact SCION 436-GC and the versatile SCION 456-GC can accommodate two columns in the oven and are available with new backflush technology and the innovative ChromatoProbe™. The new GCs are also equipped with the multi-language touchpad display supporting 13 languages and enabling MS control....
Open the catalog to page 6
Additions to Enhance System Capability and Performance SHS-40 Automated Headspace Sampler Perfect for analyzing VOCs in solid or liquid samples 40/125 sample capacity – Crimp cap or screw cap 10 or 20 mL vials 12 position oven for increased throughput 200 °C sample heating for extended range Injection with 1 mL sample loop, designed for EPC GCs MHE mode via single puncture ensuring no leaks ATOMX® Purge and Trap (P&T) System from Teledyne Tekmar ChromatoProbe™ Added versatility for superior analysis of solids, liquids, and slurries Compounds such as street drugs, industrial solids,...
Open the catalog to page 7
to change specifications without notice. © BDAL 04-2012. #281755 Bruker Daltonics is continually improving its products and reserves the right For research use only. Not for use in diagnostic procedures.
Open the catalog to page 8All Bruker Daltonics catalogs and technical brochures
-
Maritime Detection Systems
7 Pages
-
SVGps
4 Pages
-
RAPIDplus
7 Pages
-
TIMON
13 Pages
-
RoadRunner
5 Pages
-
MATRIX-MG Series
7 Pages
-
MALDI Biotyper® CA System
12 Pages
-
RAID-XP
5 Pages
-
RAID-M Series
7 Pages
-
HDX Solution
2 Pages
-
EVOQ GC-TQ
8 Pages
-
timsTOF PRO
8 Pages
-
Agri Solutions brochure
8 Pages
-
PesticideScreener
8 Pages
-
Elute LC series
8 Pages
-
nanoElute®
6 Pages
-
timsTOF™
8 Pages
-
rapifleX™
8 Pages
-
amaZon SL
6 Pages
-
compact
8 Pages
-
MALDI Biotyper
56 Pages
-
rapifleX™ MALDI Tissuetyper™
8 Pages
-
MALDI PharmaPulse™
4 Pages
-
Toxtyper
6 Pages
-
impact II
12 Pages
-
maxis II
12 Pages
-
amaZon speed
10 Pages
-
Albira Brochure
12 Pages
-
prime
12 Pages
-
solarix
10 Pages
-
Metabolomics
12 Pages
-
aurora M90
10 Pages
-
Clean Room Pack
4 Pages
-
MATRIX-F FT-NIR Spectrometer
2 Pages
-
TANGO
12 Pages
-
The new autoflex? series
10 Pages
-
MM 2
6 Pages
-
µRAID
4 Pages
-
Radiation Backpack Sentry
4 Pages
-
Posterbook Metabolomics ebook
14 Pages
-
CaptiveSpray nanoBooster
8 Pages
-
solariX XR
12 Pages
-
aurora Elite
6 Pages
-
nano-Advance UHPLC
8 Pages
-
EVOQ
12 Pages
-
CaptiveSpray
4 Pages
-
ImagePrep
4 Pages
-
micrOTOF-Q II
12 Pages
-
PROTEINEER fc II
4 Pages
-
Ultraflextreme
16 Pages
-
Autoflix speed
10 Pages
-
microflex
6 Pages
-
SCION 436-GC
4 Pages
-
SCION 456-GC
4 Pages
-
GC CARE
8 Pages
-
Brochure BioTools 2.2
10 Pages
-
Brochure micrOTOF II
8 Pages
-
Brochure EASY-nLC
6 Pages
Archived catalogs
-
impact HD
12 Pages
-
RAID-M 100
6 Pages
-
compact?
6 Pages
-
micrOTOF-Q III
6 Pages
-
Toxtyper
8 Pages
-
MALDI Biotyper
12 Pages
-
Brochure MetaboliteTools 1.1
8 Pages
-
Brochure ProfileAnalysis
4 Pages