Specification Sheet * Typical values Environmental Conditions Operating humidity (relative): 5 % to 95 % Line voltage requirements:, 120 V, 230 V (±10 % nominal) Column Oven Temperature range: Temperature program ramps/holds: 24/25 Maximum temperature ramp rate: 150°C/min for all voltages and 180 °C/min with oven insert accessory Cool down rate: 400 °C to 50 °C in 4.5 minutes Temperature set-point resolution: 0.1 °C Ambient temperature reject <0.01°C change in oven for 1°C change in ambient temp Retention time Repeatability <0.008% or < 0.0008 min, based on Pentadecane under temperature program General Specifications Up to 9 EFC modules total, injector, detector and auxiliary Optional backflush ■ External events (digital output): ■ Max number of timed events: 16 ■ Two power outlets 24V (1A max. each) ■ Maximum stored internal methods: 50 (max. 30 alphanumeric characters) For research use only. Not for use in diagnostic procedures. Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. ■ Run log file (stored with the chromatogram when using CompassCDS) Local Display: ■ TFT full color screen Local Control: ■ English, German, French, Spanish, Italian, Portuguese, Cyrillic, Kanji, Chinese (standard and traditional] Thai, Korean and Dutch. Local automation: • Infinite looping • Dual and duplicate injection Ethernet: Protocol: TCP/IP Data rate: 100 Mbps Control: GC control and method parameters Analog output (optional): ■ Time programmable steps: 30 ■ Output software selectable (set individual): Synchronization signals with other devices and data systems: Data Handling and System Control: ■ CompassCDS Chromatography Data System For research use only. Not for use in diagnostic procedures. Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice.

Open the catalog to page 1
SCION 456-GC - 2

Injector Options Maximum injectors: three, operating concurrently Pneumatics: Electronic Flow Control (EFC), or manual Injector types: PTV Programmable Temperature Vaporizing* ■ COC Cold On-Column injector* ■ PWOC Packed/Wide bore On-Column injector * Including septum purge Total flow: Split range: 1-10,000 (column dependent) COC Cold On-Column Injector Total Flow: 50 mL/min (Type 23 EFC) Temperature range: ■ Ambient +10 °C to 450 °C using air cooling ■ -60 °C to 450 °C using liquid C02 cooling ■ -160 °C to 450 °C using liquid N2 cooling Maximum temperature ramp rate: 200 °C/min Vaporizing...

Open the catalog to page 2
SCION 456-GC - 3

Quick-Switch Valve Option Instantly switch between injectors/columns and detectors Configurations: automated or manual, factory or field installed Detector Options Maximum detectors: four: operating concurrently (one of which is a Single or Triple Quad MS) Pneumatics: Electronic Flow Control (DEFC) or manual Detector types: FID Flame Ionization Detector TCD Thermal Conductivity Detector ECD Electron Capture Detector NPD (TSD) Nitrogen-Phosphorus Detector PFPD Pulsed Flame Photometric Detector PDHID Pulsed Discharge Helium Ionization Detector MS Mass Spectrometry (see GC/MS brochure and...

Open the catalog to page 3
SCION 456-GC - 4

CP-8400 AutoSampler Sample capacity: 100 x 2 mL vials Large solvent wash vial: 2 x 120 mL* Dual and duplicate mode Internal standard addition SHS-40 Headspace Sampler System Features Fixed Sample Volume Configuration Sample Capacity Injection Modes Pre-programmed modes of injection syringes: 1 μL, 2 μL, 5 μL, 10 μL, 100 μL, 250 μL for liquid injection SPME PAL Combi-xt AutoSampler Sample trays: two standard and expandable to four Tray types: 98 x 2 mL vials 200 x 1 mL vials 32 x 10 mL/20 mL vials 96-well plates Dual and duplicate mode Internal standard addition Modes of operation: Liquid...

Open the catalog to page 4

All Bruker Daltonics catalogs and technical brochures

  1. SVGps

    4 Pages

  2. RAPIDplus

    7 Pages

  3. TIMON

    13 Pages

  4. RoadRunner

    5 Pages

  5. RAID-XP

    5 Pages

  6. HDX Solution

    2 Pages

  7. EVOQ GC-TQ

    8 Pages

  8. timsTOF PRO

    8 Pages

  9. nanoElute®

    6 Pages

  10. timsTOF™

    8 Pages

  11. rapifleX™

    8 Pages

  12. amaZon SL

    6 Pages

  13. compact

    8 Pages

  14. MALDI Biotyper

    56 Pages

  15. Toxtyper

    6 Pages

  16. impact II

    12 Pages

  17. maxis II

    12 Pages

  18. amaZon speed

    10 Pages

  19. prime

    12 Pages

  20. solarix

    10 Pages

  21. Metabolomics

    12 Pages

  22. aurora M90

    10 Pages

  23. TANGO

    12 Pages

  24. MM 2

    6 Pages

  25. µRAID

    4 Pages

  26. solariX XR

    12 Pages

  27. aurora Elite

    6 Pages

  28. EVOQ

    12 Pages

  29. CaptiveSpray

    4 Pages

  30. ImagePrep

    4 Pages

  31. micrOTOF-Q II

    12 Pages

  32. Ultraflextreme

    16 Pages

  33. Autoflix speed

    10 Pages

  34. microflex

    6 Pages

  35. SCION 436-GC

    4 Pages

  36. GC CARE

    8 Pages

Archived catalogs

  1. impact HD

    12 Pages

  2. RAID-M 100

    6 Pages

  3. compact?

    6 Pages

  4. Toxtyper

    8 Pages

  5. MALDI Biotyper

    12 Pages