1. Catalogs
  2. Bruker Daltonics
  3. Radiation Backpack Sentry
video corpo

Radiation Backpack Sentry

Radiation Backpack Sentry

Radiation Backpack Sentry

Product catalog summary
Overview
The Bruker Radiation Backpack Sentry is a mobile radiological detection system designed to address the threat of radioactive material release, whether deliberate or accidental. It is particularly useful for detecting threats in crowded areas and is a tool for emergency services to combat terrorism involving radiological materials.

Key Features
  • Lightweight and ergonomic design for ease of use.
  • High sensitivity gamma detector with fast automatic isotope identification.
  • Ruggedized handheld options with IP67 rating for durability.
  • Hot swappable battery operation for extended use.
  • Intuitive touch screen interface with visual and voice notifications.
  • Bluetooth earpiece for hands-free operation.
  • Automatic calibration and continuous stabilization.

Technical Specifications
  • Detector: 3” x 3” NaI(Tl) with gamma energy resolution ≤ 8% at 662 keV.
  • Gamma energy response range: 30 keV to 3 MeV.
  • Dose rate upper limit: 5 mR/hr.
  • Battery life: Over 8 hours with rechargeable batteries.
  • Weight: Under 14 lb (6.4 kg) including handheld.
  • Dimensions: Approximately 20” x 15” x 10”.
  • Water and dust resistance: IP54 detector, IP67 handheld.
  • Operating temperature range: -20 °C to +60 °C.
  • Humidity: ≤ 95% non-condensing.

Isotope Identification
The system includes libraries for identifying medical, naturally occurring, industrial, and special nuclear materials isotopes. Identification is typically achieved in 2 seconds using advanced algorithms.

Accessories
  • Standard: Bluetooth headset, battery and charger, wired earphone.
  • Optional: Ruggedized handheld, AC adapter, spare battery, USB cable, vehicle adapter.

Contact Information
Bruker Detection has divisions in Germany, the United Kingdom, and the USA, providing contact details for sales and support.
See more

Catalog excerpts

Radiation Backpack Sentry-1

Bruker Detection Corporation Radiation Backpack Sentry Radioisotope Identification innovation with integrity Radiation Detection System

 Open the catalog to page 1
Radiation Backpack Sentry-2

The Bruker Radiation Backpack Sentry The deliberate or accidental release of radioactive material is an increasing threat to modern society. Terrorists fabricating and detonating a dirty bomb with radiological material is a common scenario for emergency services. Radiological material can be easily obtained from medical waste, research facilities, and other sources. Conventional or homemade explosives can be used to disperse the poisonous material over large crowded metropolitan areas. The expected financial and emotional impact of such an attack is enormous. This could easily affect the economy...

 Open the catalog to page 2
Radiation Backpack Sentry-3

User Interface The Bruker Radiation Backpack Sentry has an easy to read intuitive user interface for data viewing. The handheld's main data view switches between current dose rate and dose rate history with a simple touch to the screen. The software automati- cally and continuously calibrates the system with a calibration reference so there is never any need for user intervention. Isotope identification is typically achieved in 2 seconds with advanced algorithms developed by Bruker. There are several key features, including spectra viewing, which are available in additional easy Standard Accessories...

 Open the catalog to page 3
Radiation Backpack Sentry-4

Technical Specifications Isotope Identification Medical isotope library: Naturally occurring isotope library: Industrial isotope library: Special nuclear materials library: System Specifications 3” x 3” (7 cm x 7 cm) NaI(Tl) .6 .6 Gamma energy resolution: Gamma energy response range: Dose rate upper limit: Automatic continuous calibration Isotope identification time: Nominally 2 seconds, designed to ANSI N42.53 Battery powered operation: Over 8 hours with rechargeable batteries (universal chargers included) Under 14 lb (6.4 kg) including handheld Water and dust resistance: IP54 detector, IP67...

 Open the catalog to page 4

All Bruker Daltonics catalogs and technical brochures

  1. MATRIX II-MG

    8  Pages

  2. RoadRunner

    8  Pages

  3. RAPIDplus

    12  Pages

  4. RAID-XP

    8  Pages

  5. SVGps

    4  Pages

  6. TIMON

    13  Pages

  7. RAID-M Series

    7  Pages

  8. HDX Solution

    2  Pages

  9. EVOQ GC-TQ

    8  Pages

  10. timsTOF PRO

    8  Pages

  11. nanoElute®

    6  Pages

  12. timsTOF™

    8  Pages

  13. rapifleX™

    8  Pages

  14. amaZon SL

    6  Pages

  15. compact

    8  Pages

  16. MALDI Biotyper

    56  Pages

  17. Toxtyper

    6  Pages

  18. impact II

    12  Pages

  19. maxis II

    12  Pages

  20. amaZon speed

    10  Pages

  21. Albira Brochure

    12  Pages

  22. prime

    12  Pages

  23. solarix

    10  Pages

  24. Metabolomics

    12  Pages

  25. aurora M90

    10  Pages

  26. TANGO

    12  Pages

  27. MM 2

    6  Pages

  28. µRAID

    4  Pages

  29. solariX XR

    12  Pages

  30. aurora Elite

    6  Pages

  31. EVOQ

    12  Pages

  32. CaptiveSpray

    4  Pages

  33. ImagePrep

    4  Pages

  34. micrOTOF-Q II

    12  Pages

  35. Ultraflextreme

    16  Pages

  36. Autoflix speed

    10  Pages

  37. microflex

    6  Pages

  38. SCION 436-GC

    4  Pages

  39. SCION 456-GC

    4  Pages

  40. GC CARE

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.