Elute LC series UHPLC Precision for MS applications Innovation with Integrity
Open the catalog to page 1Delivering Precision and Speed for Mass Spectrometry Designed for reproducibility in retention time and peak shape, Elute LC systems are available in a variety of configurations, from entry level HPLC systems to highthroughput, high-performance UHPLC systems with fully automated on-line extraction (OLE) capability. Designed For Demanding MS Application The different Elute systems are optimized to match the analytical requirements of your applications: • The Elute SP HPLC offers standard 700 bar performance for any kind of routine lab applications at a market-leading price / performance ratio....
Open the catalog to page 2Reproducible LC-MS Quantitation The Elute UHPLC system provides great s ensi ivity in LC-MS applications on EVOQ LC-TQ, t combined with an ultra-sharp peak width (FWHM) of ~ 2 seconds. Shown above is the ensitive s Chloramphenicol detection (LLOQ 0.02 ppb) well below the Minimum Required Performance Level (MRPL) of 0.3 ppb even in difficult matrix such as eggs (EU decision 2003/181/EC). Enabling fast and reliable LC-MS methods developed on the Elute UHPLC coupled to the EVOQ LC-TQ for forensic applications: quantitation of the urine alcohol metabolite markers EtS and EtG in urine by a 3...
Open the catalog to page 3Bruker Elute LC systems are built around two pairs of serially-coupled, individually-controlled, linear drive pump heads. These are to provide virtually pulse-free, precise, volumetric flow control independent of flow rate, solvent composition, and compressibility. Whether you need to transfer your UHPLC method to a lab across the hall or across the country, the robust, reliable results of Elute LC systems ensure quick and easy method transfer. The flow path of Elute LC systems has been optimized to minimize gradient delay volume. The result is high chromatographic resolution, fast gradients,...
Open the catalog to page 4High Uptime – Low Maintenance post-blank after 10 µg injection Example of near zero carry-over: Chlorhexidine 10 µg on column, Post-blank = 0.15 ng=0.0015% Pumps in the Elute LC systems incorporate true self-priming and self-purging. Once the built-in priming pump aspirates solvent through the pump heads, true prime and purge takes just a few minutes via an electrically actuated purge valve. There is no manual user intervention needed like aspiration with an external syringe pump. To ensure maximum uptime and reduce maintenance costs, Bruker Elute LC system pumps feature an active piston backwash...
Open the catalog to page 5Retention Time Stability Due to its innovative pump design, the Elute UHPLC easily stays below retention time deviations < 0.05 minutes, meeting EU SANTE 11945 I 2015 guidelines. Javier López Flores, Coordinator of Application Development Lab, Bruker Daltonics, Madrid, Spain The EU SANTE 11945/2015 for pesticide analysis demands a limit of the retention time deviation of < 0.1 min in a batch analysis. The automated Purge & Priming of the Elute enables easy and fast mobile phase exchanges resulting in saving time during daily routine work. Even after column exchanges and specifically working with...
Open the catalog to page 6On-Line Extraction (OLE): Flexibility to Maximize Sensitivity and Minimize Time of Analysis The pre-concentration capability of the Elute OLE makes it the ideal tool for the enrichment of low abundant compounds in water or in complex mixtures like clinical research samples. On-line extraction performed in combination with UHPLC separations improves the quality and consistency of results – by delivering sharper peaks and reducing the chance of operator error inherent in manual methods. Benefits of Elute on-line extraction compared to off-line processing • irect sample loading by autosampler D...
Open the catalog to page 7Fastest UHPLC Methods Near-Zero Carry Over High Sensitivity Retention Time Stability Prof. Dr. Pim Leonards, Vrije Universiteit Amsterdam – Faculty of Earth and Life Sciences, Department of Environment and Health The Elute OLE coupled to the EVOQ Elite LC-TQ demonstrates high s ensitivity for environmentally relevant chemicals such as perfluorinated compounds and flame retardants. Using the OLE to further preconcentrate our samples, we achieve quantitative analysis at ppt-level using small sample volumes, which is of great importance for human biomonitoring studies and environmental analysis."...
Open the catalog to page 88 Pages
8 Pages
8 Pages
12 Pages
8 Pages
7 Pages
4 Pages
13 Pages
12 Pages
7 Pages
2 Pages
8 Pages
8 Pages
8 Pages
8 Pages
6 Pages
8 Pages
8 Pages
6 Pages
8 Pages
56 Pages
8 Pages
4 Pages
6 Pages
12 Pages
12 Pages
10 Pages
12 Pages
12 Pages
10 Pages
12 Pages
10 Pages
4 Pages
2 Pages
12 Pages
10 Pages
6 Pages
4 Pages
4 Pages
14 Pages
8 Pages
8 Pages
12 Pages
6 Pages
8 Pages
12 Pages
4 Pages
4 Pages
12 Pages
4 Pages
16 Pages
10 Pages
6 Pages
4 Pages
4 Pages
8 Pages
10 Pages
6 Pages
8 Pages
6 Pages
6 Pages
12 Pages
8 Pages
6 Pages
12 Pages
8 Pages
4 Pages