Elute LC series
8Pages

{{requestButtons}}

Catalog excerpts

Elute LC series - 1

Elute LC series UHPLC Precision for MS applications Innovation with Integrity

Open the catalog to page 1
Elute LC series - 2

Delivering Precision and Speed for Mass Spectrometry Designed for reproducibility in retention time and peak shape, Elute LC systems are available in a variety of configurations, from entry level HPLC systems to highthroughput, high-performance UHPLC systems with fully automated on-line extraction (OLE) capability. Designed For Demanding MS Application The different Elute systems are optimized to match the analytical requirements of your applications: • The Elute SP HPLC offers standard 700 bar performance for any kind of routine lab applications at a market-leading price / performance...

Open the catalog to page 2
Elute LC series - 3

Reproducible LC-MS Quantitation The Elute UHPLC system provides great s ­ ensi­ ivity in LC-MS applications on EVOQ LC-TQ, t combined with an ultra-sharp peak width (FWHM) of ~ 2 seconds. Shown above is the ­ ensitive s Chloramphenicol detection (LLOQ 0.02 ppb) well below the Minimum Required Performance Level (MRPL) of 0.3 ppb even in difficult matrix such as eggs (EU decision 2003/181/EC). Enabling fast and reliable LC-MS methods developed on the Elute UHPLC coupled to the EVOQ LC-TQ for forensic applications: quantitation of the urine alcohol metabolite markers EtS and EtG in urine by a...

Open the catalog to page 3
Elute LC series - 4

Bruker Elute LC systems are built around two pairs of serially-coupled, individually-controlled, linear drive pump heads. These are to provide virtually pulse-free, precise, volumetric flow control independent of flow rate, solvent composition, and compressibility. Whether you need to transfer your UHPLC method to a lab across the hall or across the country, the robust, reliable results of Elute LC systems ensure quick and easy method transfer. The flow path of Elute LC systems has been optimized to minimize gradient delay volume. The result is high chromatographic resolution, fast...

Open the catalog to page 4
Elute LC series - 5

High Uptime – Low Maintenance post-blank after 10 µg injection Example of near zero carry-over: Chlorhexidine 10 µg on column, Post-blank = 0.15 ng=0.0015% Pumps in the Elute LC systems incorporate true self-priming and self-purging. Once the built-in priming pump aspirates solvent through the pump heads, true prime and purge takes just a few minutes via an electrically actuated purge valve. There is no manual user intervention needed like aspiration with an external syringe pump. To ensure maximum uptime and reduce maintenance costs, Bruker Elute LC system pumps feature an active piston...

Open the catalog to page 5
Elute LC series - 6

Retention Time Stability Due to its innovative pump design, the Elute UHPLC easily stays below retention time deviations < 0.05 minutes, meeting EU SANTE 11945 I 2015 guidelines. Javier López Flores, Coordinator of Application Development Lab, Bruker Daltonics, Madrid, Spain The EU SANTE 11945/2015 for pesticide analysis demands a limit of the retention time deviation of < 0.1 min in a batch analysis. The automated Purge & Priming of the Elute enables easy and fast mobile phase exchanges resulting in saving time during daily routine work. Even after column exchanges and specifically working...

Open the catalog to page 6
Elute LC series - 7

On-Line Extraction (OLE): Flexibility to Maximize Sensitivity and Minimize Time of Analysis The pre-concentration capability of the Elute OLE makes it the ideal tool for the enrichment of low abundant compounds in water or in complex mixtures like clinical research samples. On-line extraction performed in combination with UHPLC separations improves the quality and consistency of results – by delivering sharper peaks and reducing the chance of operator error inherent in manual methods. Benefits of Elute on-line extraction compared to off-line processing • irect sample loading by autosampler...

Open the catalog to page 7
Elute LC series - 8

Fastest UHPLC Methods Near-Zero Carry Over High Sensitivity Retention Time Stability Prof. Dr. Pim Leonards, Vrije Universiteit Amsterdam – Faculty of Earth and Life Sciences, Department of Environment and Health The Elute OLE coupled to the EVOQ Elite LC-TQ demonstrates high s ­ ensitivity for environmentally relevant chemicals such as perfluorinated compounds and flame retardants. Using the OLE to further preconcentrate our samples, we achieve quantitative analysis at ppt-level using small sample volumes, which is of great importance for human biomonitoring studies and environmental...

Open the catalog to page 8

All Bruker Daltonics catalogs and technical brochures

  1. SVGps

    4 Pages

  2. RAPIDplus

    7 Pages

  3. TIMON

    13 Pages

  4. RoadRunner

    5 Pages

  5. RAID-XP

    5 Pages

  6. HDX Solution

    2 Pages

  7. EVOQ GC-TQ

    8 Pages

  8. timsTOF PRO

    8 Pages

  9. nanoElute®

    6 Pages

  10. timsTOF™

    8 Pages

  11. rapifleX™

    8 Pages

  12. amaZon SL

    6 Pages

  13. compact

    8 Pages

  14. MALDI Biotyper

    56 Pages

  15. Toxtyper

    6 Pages

  16. impact II

    12 Pages

  17. maxis II

    12 Pages

  18. amaZon speed

    10 Pages

  19. prime

    12 Pages

  20. solarix

    10 Pages

  21. Metabolomics

    12 Pages

  22. aurora M90

    10 Pages

  23. TANGO

    12 Pages

  24. MM 2

    6 Pages

  25. µRAID

    4 Pages

  26. solariX XR

    12 Pages

  27. aurora Elite

    6 Pages

  28. EVOQ

    12 Pages

  29. CaptiveSpray

    4 Pages

  30. ImagePrep

    4 Pages

  31. micrOTOF-Q II

    12 Pages

  32. Ultraflextreme

    16 Pages

  33. Autoflix speed

    10 Pages

  34. microflex

    6 Pages

  35. SCION 436-GC

    4 Pages

  36. SCION 456-GC

    4 Pages

  37. GC CARE

    8 Pages

Archived catalogs

  1. impact HD

    12 Pages

  2. RAID-M 100

    6 Pages

  3. compact?

    6 Pages

  4. Toxtyper

    8 Pages

  5. MALDI Biotyper

    12 Pages