Autoflix speed
1 /10Pages

Autoflix speed

Autoflix speed
1 /10Pages

Catalog excerpts

Autoflix speed-1

Bruker Daltonics autoflex speed Increased Efficiency in MALDI-TOF MS think forward MALDI-TOF(/TOF)

 Open the catalog to page 1
Autoflix speed-2

Accelerated Results with Increased Speed and Efficiency The autoflex™ speed series of MALDI based mass spectrometers has been designed to significantly increase productivity across a broad range of applications. With advances in performance and system capabilities, the autoflex speed series has the power, flexibility, and utility to be deployed in many analytical operations. Tissue Imaging Edmass™-Top Down Sequencing 2D-Gels TLC-MALDI Polymer Analysis Complex samples LC MALDI PTM Analysis Lucid Proteomics System MALDI Biotyper Microorganism ID Biomarker Discovery

 Open the catalog to page 2
Autoflix speed-3

Versatility: autoflex speed The autoflex speed series contains several system options and configurations and can be customized to best suit the applications at hand. The members of the product family include: autoflex speed L autoflex speed LRF A reflectron containing system designed to include enhanced applications like peptide analysis; also capable of operation in linear mode. autoflex speed TOF/TOF A linear mode system with outstanding dynamic range optimized for high mass range (>15 kDa) applications and MALDI Tissue Imaging. A high performance system providing all the capabilities of the...

 Open the catalog to page 3
Autoflix speed-4

Harnessing the Power of Innovation The autoflex speed family of products encompasses numerous technology advances that provide researchers with: Unmatched analytical speed using smartbeam™-II, a 1 kilohertz laser and system electronics for intensive or high throughput applications. The MALDI customized smartbeam-II technology is exclusively developed, manufactured and maintained by Bruker for unsurpassed MALDI results. Expanded mass range capabilities to handle intact proteins and molecules such as large polymers. Superb broadband mass resolution and mass accuracy through proprietary PAN™ technology....

 Open the catalog to page 4
Autoflix speed-5

Reliable and Efficient Protein Analysis MALDI based mass spectrometers have been used for many years as a standard in protein and peptide analysis, particularly for proteomics research. MALDI-TOF spectrum of intact carbonic anhy drase (CA) in sinapinic acid matrix determines the molecular weight. autoflex speed TOF/TOF systems provide information-rich protein sequencing known as Top Down Sequencing (EdmassTM, TDS) whereby the N- and C-terminal amino acids from proteins or peptides are analyzed directly. This capability can be extremely useful when analyzing known proteins such as biotherapeutics....

 Open the catalog to page 5
Autoflix speed-6

Molecular Tissue Imaging One of the most exciting recent developments in MALDI-TOF is the technology to generate images of individual molecules in tissue sections. This has the potential to revolutionize the discovery of protein targets associated with disease or treatment prognosis. MALDI imaging can also be used to monitor the distributions of lipids, drugs or their metabolites throughout the tissue without the need for labeling. With its kHz speed and 20-50 µm image resolution, the autoflex speed series was specifically optimized to deliver outstanding results in truly High Definition MALDI...

 Open the catalog to page 6
Autoflix speed-7

Glycoprotein and Glycan Analyses High molecular weight proteins Turning analysis of the complex into routine Analysis of polymers and large proteins has always been challenging for mass spectrometry. The need for analysis of these molecules has even increased with the development of Biotherapeutics that often contain glycans or are PEGylated. To address these challenges, the autoflex speed has been developed with a number of enhancements that generate convincing results. Glycopeptide analysis in one hit N-linked glycopeptide from the heavy chain of a monoclonal antibody (right). The MALDI-TOF/TOF...

 Open the catalog to page 7
Autoflix speed-8

Lipid Analysis and Microorganism Identification Bruker‘s unique TLC-MALDI solution hyphenates thin-layer chromatography (TLC) and MALDI-TOF MS extending the MALDI productivity to lipid profiling, herbals, cosmetics and food analysis. The MALDI Biotyper for identification and classification of microorganisms is a revolutionary approach to definitive identification and speciation of microorganisms. TLC plates can be coated in MALDI matrix within a few minutes permitting the molecular high resolution readout of entire TLC lanes. Molecular TLC-images or chromatograms are generated by dedicated software...

 Open the catalog to page 8
Autoflix speed-9

Polymer Analysis Polystyrene Applications in the field of synthetic polymers require equally good performance in both, small to medium mass range as well as high mass analysis. The autoflex speed series is well prepared for either of these tasks: Being equipped with the latest FlashDetector technology, the instrument provides outstanding resolution (R>26,000) and mass accuracy (≤ 2 ppm) in reflectron mode to address the complexity of e.g. Outstanding performance in high molecular weight measurement. complex co-polymer samples. Due to its real on-axis detector design, operating the system in linear...

 Open the catalog to page 9
Autoflix speed-10

Technical Specifications Increased efficiency in MALDI-TOF (/TOF) 1 kHz smartbeam-II laser technology enables ultra-high data acquisition speed. Laser focus diameters down to 10 µm for high spatial resolution imaging without pixel overlap. Wide mass range resolving power up to 26,000 due to proprietary PAN™ technology. FlashDetector™ combined with new 4 GHz digitizer provides 2 ppm mass accuracy for highest confidence. MALDI Perpetual™ Ion Source with laser-based self-cleaning in minutes. Its push-button concept for removing sample and matrix debris is indispensable for kHz operation. Compass...

 Open the catalog to page 10

All Bruker Daltonics catalogs and technical brochures

  1. MATRIX II-MG

    8  Pages

  2. RoadRunner

    8  Pages

  3. RAPIDplus

    12  Pages

  4. RAID-XP

    8  Pages

  5. SVGps

    4  Pages

  6. TIMON

    13  Pages

  7. RAID-M Series

    7  Pages

  8. HDX Solution

    2  Pages

  9. EVOQ GC-TQ

    8  Pages

  10. timsTOF PRO

    8  Pages

  11. nanoElute®

    6  Pages

  12. timsTOF™

    8  Pages

  13. rapifleX™

    8  Pages

  14. amaZon SL

    6  Pages

  15. compact

    8  Pages

  16. MALDI Biotyper

    56  Pages

  17. Toxtyper

    6  Pages

  18. impact II

    12  Pages

  19. maxis II

    12  Pages

  20. amaZon speed

    10  Pages

  21. Albira Brochure

    12  Pages

  22. prime

    12  Pages

  23. solarix

    10  Pages

  24. Metabolomics

    12  Pages

  25. aurora M90

    10  Pages

  26. TANGO

    12  Pages

  27. MM 2

    6  Pages

  28. µRAID

    4  Pages

  29. solariX XR

    12  Pages

  30. aurora Elite

    6  Pages

  31. EVOQ

    12  Pages

  32. CaptiveSpray

    4  Pages

  33. ImagePrep

    4  Pages

  34. micrOTOF-Q II

    12  Pages

  35. Ultraflextreme

    16  Pages

  36. microflex

    6  Pages

  37. SCION 436-GC

    4  Pages

  38. SCION 456-GC

    4  Pages

  39. GC CARE

    8  Pages

Archived catalogs

  1. RAID-M 100

    6  Pages

  2. compact?

    6  Pages

  3. MALDI Biotyper

    12  Pages

  4. Toxtyper

    8  Pages

  5. impact HD

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.