video corpo

S8 TIGER - Spectrometry Solutions
32Pages

{{requestButtons}}

Catalog excerpts

S8 TIGER - Spectrometry Solutions - 1

Spectrometry Solutions Innovation with Integrity

Open the catalog to page 1
S8 TIGER - Spectrometry Solutions - 2

T ouch the S8TIGER((( and control its power Instrument development begins with an analysis of users’ needs and analytical requirements. What are their tasks and questions and what answers can we provide? Which solutions will exceed their expectations? In elemental analysis the analytical task is clear: which elements are in the sample and what are their respective concentrations? The answers to these questions must meet the highest requirements with respect to accuracy, sensitivity and reliability. However, users also expect the best solutions for more practical problems: How can I reduce...

Open the catalog to page 2
S8 TIGER - Spectrometry Solutions - 3

S8 TIGER with TouchControl™

Open the catalog to page 3
S8 TIGER - Spectrometry Solutions - 4

Collimator masks Vacuum seal High intensity tube Filter wheel Automatic sample recognition Curved germanium crystal ( XS-Ge-C) EasyLoad™ with sample trays Automatic mask changer Automatic crystal changer S8 TIGER with TouchControl™

Open the catalog to page 4
S8 TIGER - Spectrometry Solutions - 5

S8 TIGER – control its power

Open the catalog to page 5
S8 TIGER - Spectrometry Solutions - 6

XRF – source of speed and power The primary advantage of X-ray fluorescence (XRF) analysis is that it is independent of the chemical bonding of the elements in the sample. Other methods, such as ICP and AAS, require time-consuming, expensive and hazardous sample preparation techniques. XRF , however, can directly analyze each element without destroying the sample. With XRF measuring any type of solid or liquid is , as easy as 1-2-3. Why is XRF so easy? In XRF the sample is excited with a primary X-ray beam, , causing the sample to fluorescence. The primary X-rays eject electrons out of the...

Open the catalog to page 6
S8 TIGER - Spectrometry Solutions - 7

How does X-ray fluorescence (XRF) work? Bromine atom Ejected electron N M L K X-ray fluorescence Kα X-ray The sample is bombarded with X-rays. This excites the sample to generate X-ray fluorescence. The X-rays “shoot” individual electrons out of the atoms of the elements, primarily out of the inner atomic shells K and L. The resulting vacancies are filled up again by electrons from higher energy shells. The excess energy of these electrons is then emitted in the form of X-ray fluorescence radiation. This radiation is characteristic for each element like a fingerprint and independent of the atom’s...

Open the catalog to page 7
S8 TIGER - Spectrometry Solutions - 9

Speed & Power The goal of any analysis is to produce the most accurate results in the shortest possible time. In elemental analysis, speed leads to the shortest time-to-result and the highest sample throughput. Speed, accuracy and reliability demand outstanding technology. S8 TIGER – Speed meets power.

Open the catalog to page 9
S8 TIGER - Spectrometry Solutions - 10

Industry proven elemental analyzer Most flexible beam path Unrivaled analytical performance Lowest limit of detection Highest analytical stability S8 TIGER Performance Ease of use Lowest limit of detection S8TIGER((( – impressive technology at your command Best long term stability Ultimate light element performance Shortest time to results Highest analytical flexibility Material specific solutions Universal standardless analysis Lowest Counts per Min. Detection Second Time to Limit (cps) Result Plug’n Analyze

Open the catalog to page 10
S8 TIGER - Spectrometry Solutions - 11

General Requirement Advanced Requirement Minerals & Mining Metals & Slags Ceramics, Re- Plastics fractories, & Polymers Glass Chemistry & Catalysts Waste & Environment

Open the catalog to page 11
S8 TIGER - Spectrometry Solutions - 12

Unique analytical performance, lowest Impressive analytical robust design: Undisputed leader Sample loader: convenient operation ■ Automatic liquid sample nection via belt or robot ■ Highest intensity in class power consumption ■ High analytical perform- ance for industrial applica- . Full WDXRE most flexible beam path ■ Dust sealed cabinet ultimate light element ■ Full 4 kW for lowest limit ■ Most flexible beam path ■ Dust sealed cabinet High precision masks: Optimized beam path for smallest samples Lowest background, improved signal to noise Best possible detection Automatic mask three...

Open the catalog to page 12
S8 TIGER - Spectrometry Solutions - 13

X-ray tube: Optimized peak to background ratio for each element Highest intensity in class without cooling water Up to 50 kV or 50 mA 4 kW: Superior analytical performance Highest excitation intensity Huge selection of filter materials and thicknesses (Al, Cu, Brass) X-ray tube window protection (DuraBeryllium shield – optional) 170 mA at 4 kW Closest coupling anode to sample Light and heavy elements, solids and liquids, ppb to 100 % ... the demands made on XRF are challenging and diverse. In order to provide the perfect solution to any analytical question, we have integrated cutting-edge...

Open the catalog to page 13
S8 TIGER - Spectrometry Solutions - 14

Electronic gearing : The fastest, high-precision scanning – monitoring of samples in less than 2 minutes Electronic gearing Accurate and precise positioning High speed scans Shortest time-to-results Highest sample throughput High intensity X-ray source: The strongest – 170 mA and 24 kV at full 4 kW; best light element performance Intensity High intensity X-ray source Photon emission [%] 170 mA for best light element analysis Full 4 kW for highest sensitivities Most compact beam path, shortest sample to anode distance Cool tube head for delicate samples XS-CEM analyzer crystal: The benefit is...

Open the catalog to page 14
S8 TIGER - Spectrometry Solutions - 15

S8TIGER((( – the fastest, the strongest and the fittest Survival of the fittest! In XRF fitness is determined by means of two , decisive factors - performance and speed; in order to survive, the most reliable and best possible results are needed. Apart from its powerful, compact appearance, what makes our S8 TIGER the power pack for all elements? Performance begins at the source of excitation. The new high intensity X-ray tube offers over 20% higher intensity compared to conventional X-ray tubes. Due to the great flexibility of the voltage and current, it permits target excitation of the...

Open the catalog to page 15
S8 TIGER - Spectrometry Solutions - 17

, EasyLoad™ & SampleCare™ Anyone can perform measurements; operation is simple and intuitive. These are not just dreams, but the reality of TouchControl with the S8 TIGER. Safe sample handling, automatic recognition, instant switching between solids and liquids, accommodating various sample sizes and a large sample magazine … in two words, EasyLoad and SampleCare. S8 TIGER – the touch of your finger is all it t

Open the catalog to page 17

All Bruker AXS catalogs and technical brochures