S2 LION - Spectrometry Solutions
12Pages

{{requestButtons}}

Catalog excerpts

S2 LION - Spectrometry Solutions - 1

S8 LION Spectrometry Solutions think forward

Open the catalog to page 1
S2 LION - Spectrometry Solutions - 2

Simultaneous XRF: S8 LION((( – leader of the power pack 100,000 cubic meters of raw material, 10,000 tons in daily production, 80 tons of loading volume - the dimensions and expenses in industrial sectors such as cement, mining and industrial minerals are gigantic. The investments are correspondingly big and production has to keep on running and running. Not just because of the costs, but primarily for process stability, all processes must function reliably, smoothly and maintain the same high quality. It goes without saying that all raw materials, intermediate compounds and final products...

Open the catalog to page 2
S2 LION - Spectrometry Solutions - 3

Bent Crystals Flexible sample handling X-ray warning lights SampleCare™ – Tube above S8 LION – Leader of the power pack Automated sample loader Automation interface Process samples S8 LION – simple oper

Open the catalog to page 3
S2 LION - Spectrometry Solutions - 4

How does X-ray fluorescence (XRF) work? Bromine atom Ejected electron N M Simultaneous XRF – dedicated performance, tailor-made X-ray fluorescence Kα X-ray The sample is bombarded with X-rays. This excites the sample to generate X-ray fluorescence. The X-rays “shoot” individual electrons out of the atoms of the elements, primarily out of the inner atomic shells K and L. The resulting vacancies are filled up again by electrons from higher energy shells. The excess energy of these electrons is then emitted in the form of X-ray fluorescence radiation. This radiation is characteristic for each...

Open the catalog to page 4
S2 LION - Spectrometry Solutions - 5

Power & Performance In elemental analysis for process control there is only one thing that counts: to obtain the most accurate and precise results as fast as possible! This kind of top-rate performance can only be achieved and maintained over time by means of an ideal combination of maximum sensitivity, compact beam path, and optimal channel geometry. The LION’s share: sixteen channels royally tuned for the 26 elements most important to the industrial sectors of cement, industrial minerals and mining, and a XRD free-lime channel – unique! S8 LION – enjoy the power of sixteen – 24/7/36

Open the catalog to page 5
S2 LION - Spectrometry Solutions - 6

Teamwork at its best: you define the task; we deliver the S8 LION((( ready for action! Cement – Basic Elements Na Raw mix control important for fusion process Raw mix control, important for color and fusion process Cement – Advanced Needs Free Lime Control (source: secondary fuels) Prevent corrosion, harmful to hydration process, cyclone blockage Chromate reduction, toxic Toxic, (source tyres TDF) Sulphur speciation: Slags, raw materials Additional Elements for Industrial Minerals Ti Nickel laterite, impurities Industrial Minerals Alumina Bauxite Quartz Dolomite Iron ores Zircon sands ......

Open the catalog to page 6
S2 LION - Spectrometry Solutions - 7

X-ray tube: Superior analytical performance Bent analyzer crystals: Highest excitation intensity In industries with large flows of materials, enormous quantities of valuable raw materials are handled in elaborate processes. The task of PC/QC is therefore clear: to deliver extremely accurate results, immediately and reliably! Logarithmic bent shape of crystals for highest intensity and resolution Closest coupling of anode to sample Temperature-stabilized crystals for highest stability Up to 170 mA at 4 kW for ultimate light element performance Optimized element channels: Background optimized:...

Open the catalog to page 7
S2 LION - Spectrometry Solutions - 8

TouchContr ol™, EasyLoad™ & SampleCare™ Anyone can perform measurements, operation is child’s play and intuitive … this is not fiction; it is the real world of TouchControlTM on the S8 LION. Constant availability, no wear and tear, absolutely unfazed by sample failures, straightforward integration to an automation solution … This is unrelenting reliability. In other words: EasyLoadTM and SampleCareTM!

Open the catalog to page 8
S2 LION - Spectrometry Solutions - 9

The ultimate in ease-of-use – S8 LION((( How much training is required to operate the S8 LION? None, thanks to TouchControl™! This is because operation is incredibly easy: the user places a sample in the magazine and taps the touchscreen once. The predefined automatic measuring program starts at once and delivers the result: right on time, good as done. S8 LION with TouchControl™, EasyLoad™ & SampleCare™ Behind the scenes, the predefined measuring program automatically assigns the name, transmits the measured data to the control center or the LIMS system and immediately displays the result on...

Open the catalog to page 9
S2 LION - Spectrometry Solutions - 10

SPECTRAplus – all you ever need The ultimate in ease-of-use – S8 LION((( Obviously you want to know more about calibration, evaluation and reporting. You need to have maximum functionality paired with extremely easy operation. May we present to you: SPECTRAplus! How much training is required to operate the S8 LION? None, thanks to TouchControl™! CALIBRATION 1 Element with selected analytical line 2 Calculated deviation of the calibration 3 Calibration curve 4 Matrix correction model: FP, variable alpha model, empirical, theoretical,… We will keep it short: Our SPECTRAplus software package...

Open the catalog to page 10
S2 LION - Spectrometry Solutions - 11

Lowest maintenance and best system uptime with tube-above geometry S8 LION((( – always ready for the next job Precise and reproducible results due to absolute reference position Sample handling – fit for every purpose Safe, fast and precise sample handling with SampleCareTM and EasyLoadTM A) Sample Magazine for cups Dust Sample failure Precision, reproducibility, accuracy, reliability and uptime are mandatory in process control! EasyLoad™ and SampleCare™ are up to the challenge. Most flexible sample handling with cups and 8 positions Samples up to 51.5 mm diameter Mask size 28 or 34 mm...

Open the catalog to page 11
S2 LION - Spectrometry Solutions - 12

Technical Data Systems X-ray power Configurations: Up to 16 element channels or free-lime channel plus up to 13 element channels Up to 6 absorbers (50%, 80%, 95% - silver or stainless steel) Proportional flow counters with windows: 0.6 μm, 1.5 μm, Sealed proportional counter: 25 μm Be, Scintillation counter Sample handling 8 position Cups 10 position 51.5 mm sample rings 12 positions 40 mm sample rings ONLINE 8 positions 51.5 mm sample rings with conveyor belt ONLINE 9 positions 40 mm sample rings with conveyor belt Vacuum system Vacuum pump integrated Automated sample drawer with 12...

Open the catalog to page 12