Technical Specifications:
The document provides detailed specifications for various cable types, including cross-section, part number, conductor code, diameter over copper shield (Ø d1), overall diameter (Ø D), copper weight (Cu-number), and total weight per kilometer. The cables range from 3x1.5 mm² to 5x10 mm², with varying dimensions and weights.
Application:
The WILBAflex EMC, FRNC/FRNC cables are designed for environments requiring high flame resistance and low flammability, such as SF6 switchgear, engines, and machine tool manufacturing. They are suitable for both indoor and outdoor use.
Construction:
The cables feature a copper cord flex, class 5 (IEC 60228), with finely wired construction, FRNC insulation, a tinned copper shield, and an FRNC sheath.
Description:
The cables are halogen-free and hardly combustible, complying with IEC 60332-3C standards. They have a nominal voltage of 300/500 V for cables ≤ 1 mm² and 600/1000 V for cables ≥ 1.5 mm². The test voltage is 2000 V / 50 Hz for cables ≤ 1 mm² and 3500 V / 50 Hz for cables ≥ 1.5 mm². The minimum bending radius is 15 times the cable diameter.
Temperature Range:
The operational temperature range is from -25°C to +90°C.
Jacket Colour:
The cables are black, similar to RAL 9005.
Standards:
The cables meet several standards, including IEC 60332-1 for flame retardancy, IEC 60332-3 for fire retardancy, IEC 60754-1 for being halogen-free, IEC 60754-2 for no corrosive gases, and IEC 61034-1 for low smoke emissions. They also have a Gost-R Fire-Certificate (Russia) and SEV TP20B/3C certification.
Remarks:
Other cable types are available upon request. The document notes that specifications are subject to change without notice.
See more