Catalog excerpts
V994 ShakerMetric Performance Parameters Used where large payloads need high performance vibration or shock testing, the V900 series gives engineers the confidence they need to develop highly reliable products. These systems have been used in single and multi-shaker configurations, and have been used to test products such as satellites and missiles. Features • Combination of high performance armature design and water-cooled coils deliver excellent acceleration and velocity performance • Automatic armature and body position load compensation system ensures larger loads can be comfortably accommodated • Trunnions feature Lin-E-Air suspension system as standard. Solid trunnions available upon request System Performance Max. Acceleration (sine peak) Random Force (rms) Max. Acceleration (random rms) Velocity (sine peak) Health and Safety Complies with the following EU directives: Machinery 2006/42/EC, Low Voltage 2006/95/EC, EMC 2004/108/EC Designed in accordance with EN 61010-1:2001 Industry Applications • 3-axis testing of complete satellite systems • Avionics and military hardware testing • Structural dynamics testing • Clean room environments • Multi-shaker, multi-axis applications Force and velocity ratings depend on the amplifier driving the shaker. The sine force, random force and velocity parameters detailed here are based on the shaker when driven by the DPA 280 K amplifier. r Random and shock ratings assume a payload approximately twice the mass of the armature; shock pulse 2 ms. For advice on specific test requirements, contact Bruel & Kj^r. * Theoretical maximum, measured 150 mm above table, full-field, at normal operating temperature. Bruel & Kjser
Open the catalog to page 1Some of the features listed are available as standard, others as options. Please contact Bruel& Kj®r for advice on the optimum specification to meet your system needs Power Range 90-280kVA in 8 kVA increments Signal-to-noise Ratio >65 dB, relative to 100Vrms output, 10 kQ input termination and rated resistive load connected (100 kHz BW) Input Impedance 10 kQ nominal Total Harmonic 0.5-0.8% at rated output into Distortion resistive load Input Sensitivity 1.1 V (±0.1 V rms input) for (400 Hz, Master Gain 100Vrms output at rated fully CW) sinusoidal Volt Amp output Switching...
Open the catalog to page 2All Bruel and Kjaer catalogs and technical brochures
-
Data Analysis Software
6 Pages
-
B&K 2245 Sound Level Meter
8 Pages
-
HBK 2255 Sound Level Meter
10 Pages
-
Artificial Mastoid Type 4930
6 Pages
-
Power Amplifier Type 2718
2 Pages
-
DISCOM Mobile
6 Pages
-
DISCOM NVH Analysis Systems
4 Pages
-
TEDS Microphones
8 Pages
-
LDS V8
4 Pages
-
LDS Comet USB
4 Pages
-
LDS Laser USB
16 Pages
-
2690-A
16 Pages
-
4374
2 Pages
-
4326-A-001
8 Pages
-
4152
4 Pages
-
4191
2 Pages
-
2719
2 Pages
-
LDS V8900
4 Pages
-
BKS 10
8 Pages
-
1704-A-001
4 Pages
-
4939
2 Pages
-
4138
4 Pages
-
4101-B and 4965-B
4 Pages
-
Sonoscout NVH Recorder
8 Pages
-
LDS Power Amplifiers
8 Pages
-
Type 2720
2 Pages
-
Type 2721
2 Pages
-
TYPE 3668
4 Pages
-
3656-A
4 Pages
-
TYPE 2270-S
28 Pages
-
TYPE 8702
16 Pages
-
BZ-7848-A
40 Pages
-
TYPE 9718-A:bp0317
12 Pages
-
TYPE 4720:bp1974
12 Pages
-
TYPE 4824:bp1936
4 Pages
-
SOUND LEVEL METER:bp 2025
28 Pages
-
Transducers and conditioning
188 Pages
-
Noise Sentinel Overview
3 Pages
-
Analyzer Catalogue
39 Pages
-
Noise Logger Type 3659
1 Pages
-
Sound level meters
17 Pages