1. Catalogs
  2. Brownell Ltd
  3. Panel Mounting Desiccators

Panel Mounting Desiccators

Panel Mounting Desiccators

Product catalog summary
Overview: Brownell panel mounted humidity adsorbers are designed to protect electronic, electrical, and optical equipment from high humidity, mould growth, condensation, corrosion, and electrical breakdown by reducing moisture to acceptable levels. They include saturation indicators for reactivation or replacement.
Key Features:
  • Applicable to electronic, electrical, and optical equipment, cameras, storage containers, laser systems, and high voltage junction boxes.
  • Relative humidity indication level ranges from 15% to 80%.
  • Robust construction with an Ultra Clean option available.
  • Easy installation with operating temperatures from -40°C to +90°C.
  • Capacity ranges from 0.5 to 500g, refillable and re-activatable.
  • Available in static and breather desiccators with plastic and metal housings.
Product Specifications:
  • BLD5060: Thread M20-M35, Overall Length 40-130mm, Humidity Indication Level 30% / 50% Rh.
  • BLD6088: Thread 3/4”x20, Overall Length 46-122mm, Humidity Indication Level 50% Rh.
  • BLD6342: Thread M38-M72, Overall Length 37-52mm, Humidity Indication Levels 15% / 30% and 30% / 50%.
  • BLD8743: Thread M32, Overall Length 121mm, Humidity Indication Levels 15% / 30% and 30% / 50%.
  • BLD5267: Thread M35, Overall Length 120mm, Humidity Indication Level N/A.
Contact Information: Brownell Ltd., Unit 2, Abbey Road Industrial Park, Commercial Way, Park Royal, London, NW10 7XF. Phone: +44(0) 20 8965 9281, Fax: +44(0) 20 8965 3239, Email: [email protected], Website: www.brownell.co.uk
See more

Catalog excerpts

Panel Mounting Desiccators-1

Electronic, electrical & optical equipment protection Brownell panel mounted humidity adsorbers have been designed to protect all types of equipment. Including electronic, electrical and optical equipment against harmful effects of high humidity, mould growth, condensation, corrosion and electrical breakdown. By reducing any existing or incoming moisture to acceptable levels, these problems can be prevented. Saturation indicators built-in to the desiccators show when reactivation or replacement is required. Desiccators are filled with powerful adsorbing agents including silica gel and molecular sieves. Relative humidity indication level from 15% - 80% Electronic equipment Robust construction Ultra Clean option available Easy installation Operating temperature from - 40°C to +90°C Capacity 0.5—500g Refillable Re-activateable Static and breathers desiccators Plastic and metal housings Electrical equipment Optical equipment Cameras Storage containers Laser systems High voltage junction boxes Overall Length Humidity Indication Level Brownell Ltd. | Unit 2 | Abbey Road Industrial Park, | Commercial Way | Park Royal | London | NW10 7XF T: +44(0) 20 8965 9281 | F: +44(0) 20 8965 3239 | [email protected] | www.brownell.co.uk

 Open the catalog to page 1

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.