Overview: The GT1600 Model is a versatile thermal mass flow meter suitable for both retrofitting and new installations. It features a 360-degree rotatable viewing angle and is built with durable materials for both indoor and outdoor use.
Specifications:
  • Material: Constructed with a 316 stainless steel frame, polycarbonate safety shield, and dual certified 316/316L stainless steel process fittings.
  • Flow Accuracy: Standard accuracy ranges from ±10% to ±2% full scale, with an optional ±1% full scale.
  • Temperature Limits: Ambient temperature ranges from ‐4°F to 125°F, and operating fluid temperature ranges from 33°F to 250°F.
  • Mounting Options: Available in in-line, panel-mount, and wall-mount configurations.
Features:
  • Compatible with retrofitting GT10xx, GT130x, and Full-View models.
  • Optional alarms for high and low flow.
  • Flanged or threaded connections for horizontal and vertical installations.
  • Easy maintenance with in-situ cleaning or replacement of tube and float.
  • Optional integral needle valve for flow adjustment.
Product Specifications:
  • Capacities and Pressure Drops: Detailed specifications for various tube sizes and materials, indicating pressure ratings and flow capacities.
  • Materials: Includes Viton®, Buna N, Kalrez®, EPDM, Teflon®, and borosilicate glass.
  • Certifications: International Calibration Certificate, Material Certification to DIN 3.1, and Declaration of Compliance 2.1 for Oxygen Service.
Product Approvals:
  • Certified for intrinsic safety and encapsulation methods, compliant with ATEX and IECEx standards.
  • Compliant with EMC and RoHS Directives.
Model Code and Options:
  • Options for horizontal and vertical inlet/outlet configurations.
  • Flow/Scale Lengths available in 250mm, 127mm, and 75mm for high and low flow applications.
  • Detailed codes for maximum flow rates for water and air, with specific tube and float configurations.
Additional Specifications:
  • Fitting Material: Options include 316 Stainless Steel and 316 Stainless Steel with CRN.
  • Connection Size and Type: Sizes range from 1/4” for low flow to 1” for high flow, with NPT - Female and ANSI #150 RF Flange types.
  • O-Ring Material: Options include Viton® fluoroelastomer, Buna, Kalrez®, and EPDM.
  • Scale Inscription and Meter Accuracy: Options include MM Scale, Percent Scale, Direct Reading Scale, and Dual Scale with accuracy from ±10% to ±1% Full Scale.
  • Valve Type/Location and Alarm Options: Valves can be located at the inlet or outlet, with alarm options including none, 1 switch/sensor, or 2 switches/sensors.
Approvals: Includes ATEX and UL/FM certifications for hazardous locations.
Accessory Parts & Services: Offers cleaning services, compliance declarations, calibration certificates, material certifications, and pressure test certificates. Additional parts like junction box assemblies and mounting kits are available.
Service and Support: Brooks Instrument provides global repair facilities, start-up services, in-situ calibration, and customer training seminars, emphasizing quality and continuous improvement.
Trademarks: Brooks Instrument, LLC holds the trademark for Brooks, with other trademarks belonging to their respective owners.
See more

Catalog excerpts

GT1600 Series-1

DATA SHEET Variable Area Flow Meters Thermal Mass Flow Industrial, Glass Tube Variable Area Flowmeter (Rotameter) for Liquids & Gases Configurable to retro-fit GT10xx, GT130x and Full-View 360 degrees rotatable viewing angle High quality materials for safety, in- and outdoor durability 316 stainless steel frame Polycarbonate safety shield 316/316L dual certified stainless steel process fittings Alarms for high- and low flow (optional for all flow ranges, either at time of order,or as add-on in the field) Flanged or threaded connections, available horizontal and vertical Panel- and wall mount options Easy in-situ maintenance: Clean or replace tube and float without removal from the process piping Adjust the scale to compensate for process variation • Optional integral needle valve Product Specifications Flow Accuracy Standard: ±10%, ± 5%, ±2% Full Scale, Class 2.5 acc VDI/VDE Optional: ±1% Full Scale, Class 1.6 acc VDI/VDE Capacities and Pressure Drops Transparant scale. Adjustable Nominal Lengths: 75mm, 127mm and 250mm Choice of direct reading units, millimeter or percentage of maximum flow with factor tag Ambient Temperature Limits Operating Fluid Temperature Limits Mounting options In‐line Panel‐mount (see Dimensions) Wall‐mount (see Dimensions)

 Open the catalog to page 1
GT1600 Series-2

Product Specifications NPT Threaded Horizontal IN/OUT Ver�cal IN/OUT Horizontal IN/ Ver�cal OUT Ver�cal IN/ Horizontal OUT Process connec�ons Pressure Ra�ngs Tube size 02 06 07 08 09 10 Materials of construc�on Metering Tube (we�ed) Process fi�ngs (we�ed) Float (we�ed) Float Stops (we�ed) O rings (we�ed) Housing Window & safety shield Hardware Tube size 02&06 Tube size 07 10 Hazardous area approvals Maximum Opera�ng Pressure (PSIG | bar) at Fluid Temperature Threaded process connec�ons Flanged process connec�ons psi bar psi bar 300 20.7 240 16.5 300 20.7 240 16.5 300 20.7 240 16.5 250 17.0 240...

 Open the catalog to page 2
GT1600 Series-4

Product Specifications - Dimensions

 Open the catalog to page 4
GT1600 Series-5

Product Description - Dimensions Meter type 127-Low Flow Or n H(orizontal) V(er al) H-IN / H-OUT V-IN / V-OUT H-IN / V-OUT V-IN/ H-OUT H-IN / H-OUT V-IN / V-OUT H-IN / V-OUT V-IN/ H-OUT H-IN / H-OUT V-IN / V-OUT H-IN / V-OUT V-IN/ H-OUT H-IN / H-OUT V-IN / V-OUT H-IN / V-OUT V-IN/ H-OUT H-IN / H-OUT V-IN / V-OUT H-IN / V-OUT V-IN/ H-OUT H-IN / H-OUT #7/8 H-IN / H-OUT #9/10 V-IN / V-OUT #7/8 V-IN / V-OUT #9/10 H-IN / V-OUT #7/8 H-IN / V-OUT #9/10 V-IN/ H-OUT #7/8 V-IN/ H-OUT #9/10 V-IN / V-OUT H-IN / H-OUT #7/8 H-IN / H-OUT #9/10 V-IN / V-OUT H-IN / V-OUT #7/8 H-IN / V-OUT #9/10 V-IN/ H-OUT #7/8...

 Open the catalog to page 5
GT1600 Series-6

Product Specifications - Dimensions Tube size Meter type 127 High Flow 07 08 09 10 Orientation H(orizontal) V(ertical) H IN / H OUT V IN / V OUT H IN / V OUT V IN/ H OUT H IN / H OUT #7/8 H IN / H OUT #9/10 V IN / V OUT #7/8 V IN / V OUT #9/10 H IN / V OUT #7/8 H IN / V OUT #9/10 V IN/ H OUT #7/8 V IN/ H OUT #9/10 V IN / V OUT H IN / H OUT #7/8 H IN / H OUT #9/10 V IN / V OUT #7/8 V IN / V OUT #9/10 H IN / V OUT #7/8 H IN / V OUT #9/10 V IN/ H OUT #7/8 V IN/ H OUT #9/10 H IN / H OUT #7/8 H IN / H OUT #9/10 V IN / V OUT #7/8 V IN / V OUT #9/10 H IN / V OUT #7/8 H IN / V OUT #9/10 V IN/ H OUT #7/8...

 Open the catalog to page 6
GT1600 Series-7

Product Approvals Overview Product Approvals Overview Inductive Alarm Reed Switch Meter Options  Pressure Equipment Directive (2014/68/EU) Declaration EMC Directive (2014/30/EU) The equipment uses a reed sw itch sensor & is outside the scope of the directive since the inherent nature of the physical characteristics of w hich is such that: (i) it is incapable of generating or contributing to electromagnetic emissions w hich exceed a level allow ing radio and telecommunication equipment and other equipment to operate as intended; and (ii) it operates w ithout unacceptable degradation in the presence...

 Open the catalog to page 7
GT1600 Series-8

Model Code Code Description I.-II. Base Model Number Code Option Option Description 16 III. Body - Flow/Scale Length 1 2 3 4 Horizontal Inlet and Outlet Body Flow 250-High Flow 127-High Flow 075-High Flow 127-Low Flow Horizontal Inlet - Horizontal Outlet Vertical Inlet - Vertical Outlet Horizontal Inlet - Vertical Outlet Vertical Inlet - Horizontal Outlet Initial release of global model code Model Revision 127 - High Flow Water Air Code GPM l/h SCFM m3n/h Tube SC 0.41 93 1.8 3.1 S R-7M-127-1FT C SF 0.66 150 2.7* 4.6* S R-7M-127-1FT F TC 0.99 220 4 6.9 T R-8M-127-4FT C TF 1.3 310 5.3 9.1 T R-8M-127-4FT...

 Open the catalog to page 8
GT1600 Series-9

Model Code Code Description Code Option Option Description 316 Stainless Steel 316 Stainless Steel w/ CRN Standard / GT1000 Retrofit NPT - Female Standard / GT1000 Retrofit ANSI #150 RF Flange Retrofit GT130x NPT - Female Retrofit Full-View 11xx   NPT - Female Retrofit Full-View 11xx   ANSI 150# RF Flange Retrofit GT1000  Rc - Female\ Low Flow High Flow High Flow High Flow Vertical / 3/4” Horizontal. Size 10 only. Viton® fluoroelastomer Buna Kalrez® EPDM XIII. Scale Inscription MM Scale Percent Scale Direct Reading Scale Dual Scale ±10% ±5% Full Scale ±2% Full Scale ±1% Full Scale 2.5 VDI/VDE...

 Open the catalog to page 9
GT1600 Series-10

Accessory Parts & Services * These parts and services are not part of the product model code but should be selected during product configuration. Accessory Parts CONDULET JUNCTION BOX ASSEMBLY from 16xxG Model Code, position 16 Op�on Code Part Numbers for Relays RELAY Part Numbers for Relays from 16xxG Model Code, position 16 Alarm Op�on Code None 1 Switch/Sensor 2 Switches/Sensor FRONT OF PANEL MOUNTING KIT #2-6 #7-10 BACK OF PANEL MOUNTING KIT #2-6 #7-10 Services Clean for Oxygen Service 2.1 Commercial Cleaning Declaration of Compliance 2.1 International Calibration Certificate (ICC) Material...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.