1. Catalogs
  2. Brooks Instrument
  3. 122 Series Pressure Switches & Transmitters

122 Series Pressure Switches & Transmitters

122 Series Pressure Switches & Transmitters

122 Series Pressure Switches & Transmitters

Product catalog summary
Overview: The Brooks Instrument IPS & IPT122 are 2-inch stainless steel pressure switches and transmitters designed for high purity and precision in pressure measurement. The IPS122 functions as a pressure switch with adjustable setpoints, while the IPT122 serves as a pressure transmitter with high accuracy and multiple output options.
Key Features:
  • Compact design for easy installation in gas systems.
  • Local and remote pressure monitoring capabilities.
  • High purity suitable for various application environments.
  • Solid-state design for hazardous environments.
  • Switches are welded in oxygen-free chambers for safety and cleanliness.
Specifications:
  • Pressure range: Vacuum to 4,000 PSI (276 bar).
  • Gauge dial accuracy: 1% of full scale.
  • Operating temperature: 0° to 160°F (-18° to 71°C).
  • Materials: 300 Series Stainless Steel, 316L Stainless Steel for critical components.
  • Output options for IPT122: 0-5 Vdc, 1-5 Vdc, or 4-20 mA.
Applications: Primarily used in gas delivery systems and semiconductor processing tools, including bulk gas and gas cabinets.
Service and Support: Brooks Instrument offers global repair facilities, start-up services, in-situ calibration, and customer training seminars to ensure optimal product performance and compliance with international standards.
See more

Catalog excerpts

122 Series Pressure Switches & Transmitters-1

DATA SHEET Pressure 2 Inch Stainless Steel Indicating Pressure Switches/Transmitters The Brooks Instrument IPS & IPT122 2 Inch stainless steel Pressure Switches/ Transmitters provide a high purity, precision pressure gauge and electronic switch/ indicator, with the switches having an adjustable pressure switch setpoint. The IPS122 is a compact unit that has the ability to operate lights or relays up to a maximum of 12 watts. The IPT is accurate within 1% of full scale, and can provide 0-5 Vdc, 1-5 Vdc, or 4-20 mA outputs with pressure ranges up to 4000 psi. - Compact unit for easy installation into new or existing gas systems - Local or remote indicaton of switch interlock/system presure against undesirable process pressure conditions to ensure process accuracy and protect product yields - High purity for use in all application environments Features IPT122 • Solid-state design with 1 to 5 Vdc, 0 to 5 Vdc or 4 to 20 mA outputs • Universal output configuration available • Local and remote pressure monitoring • Interfaces with automatic purge systems, PLCs or data acquisition systems IPS122 • Local and remote alarm capability • Local indication of pressure reading and switch position (normally open or normally closed) • Solid-state design for hazardous environments • Switches welded in oxygen-free chambers to meet rigid cleanliness and safety guidelines • 1 year warranty Applications Gas delivery systems and tools used for semiconductor processing, including: • Bulk gas • Gas cabinets View IPS122/IPT122 Product Page

 Open the catalog to page 1
122 Series Pressure Switches & Transmitters-2

Product Specifications - IPS122 / IPT122 Specifications Pressure Ranges Gauge Dial Accuracy IPS122 / IPT122 Vacuum to 4,000 PSI (276 bar). Metric also available (See Range Tables) 1% of full scale Helium Leak Check Response Time Less than 200 milliseconds Proof Pressure Design Pressure Burst Pressure Operating Temperature - Ambient Compensating Temperature Storage Temperature Cleaning -20° to 175°F (-29° to 79°C) Cleaned for oxygen service to ANSI B40.1 level IV specifications Materials of Construction:   Case Bezel and Lens Socket Movement Bourdon Tube Connections Dial Approximate Shipping Weight...

 Open the catalog to page 2
122 Series Pressure Switches & Transmitters-3

* All figure intervals and smallest interval depicted in this chart represent typical artwork layout and may not be accurate for all gauges. Note: All ranges are in Hg and/or psi. If a scale other than Hg or psi is required, convert the pressure range code to the customer-specified units and use that in the product description code when specifying the product. For dual range specify the range code for the first engineering unit (ex. For a dual range with units of KGC/IKPA the range should be specified in KGC). Product Dimensions

 Open the catalog to page 3
122 Series Pressure Switches & Transmitters-4

Model Code Code Description Code Option Option Description I. Base Model Number IPS122 Pressure Switch II. Pressure Range See options in Range Tables PSI PSI/Bar MPa Bar PSI/KGC VM VSM VSF NPT 1 2 Pounds per Square Inch Pounds per Square Inch and Bar Megapascal Bar Pounds per Square Inch and Kilograms per Square Centimeter Pressure Range Face seal male Face seal swivel male Face seal swivel female 1/4” NPT male *(Refer to Specifications Table for output voltage and current draw) VI. Trip Position Code Description Code Option Option Description I. Base Model Number IPT122 Pressure Transmitter...

 Open the catalog to page 4
122 Series Pressure Switches & Transmitters-5

Service and Support Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up. We operate first class repair facilities located around the world to provide rapid response and support. Each location utilizes primary standard calibration equipment to ensure accuracy and reliability for repairs and recalibration and is certified by our local Weights and Measures Authorities and traceable to the relevant International Standards. Visit www.BrooksInstrument.com to locate the service location nearest...

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.