Introduction
Bronkhorst High-Tech B.V. is a prominent European manufacturer specializing in thermal Mass Flow Meters/Controllers and Electronic Pressure Controllers. With over 40 years of experience, their customizable instruments are suitable for laboratory, industrial, and hazardous environments.

LOW-ΔP-FLOW Series
This series is tailored for applications requiring minimal differential pressure or handling corrosive gases. It features a large bore capillary and cylindrical flow splitter to reduce flow resistance, supporting mass flow capacities from 0…10 mln/min to 0…1000 m3n/h. The design minimizes clogging and eases cleaning, enhancing durability when used with corrosive gases. Wetted parts are made of stainless steel, with options for Hastelloy or Monel.

Industrial and Laboratory Use
Based on the EL-FLOW series, the LOW-ΔP-FLOW series can be equipped with an IP65 housing for industrial settings and is ATEX Category 3 approved for Zone 2 hazardous areas. It supports digital communication protocols like DeviceNet™, CANopen®, and PROFIBUS®DP.

Mass Flow Control
The series includes compact Mass Flow Controllers (models F-200/201/202) known for fast and smooth control. For higher flow rates at low differential pressures, special control valves with pressure compensation bellows (series F-004) are available.

Features
  • Very low pressure drop
  • Suitable for corrosive gases
  • Larger flow channels to minimize clogging
  • IP65 housing and ATEX approval for hazardous areas
  • Fieldbus interfaces for various communication protocols


Technical Specifications
Accuracy is ±1% FS, with a turndown ratio of 1:50. Operating temperature ranges from -10 to +70°C, with a maximum operating pressure of 10 bar. Instruments require a 30-minute warm-up for optimal accuracy.

Applications
The LOW-ΔP-FLOW series is used in environmental air sampling, leak rate measurements, burner control, and gas consumption measurement in low-pressure systems. It offers advantages in burner control by automatically adapting to changing conditions.

Models and Flow Ranges
Detailed specifications for various models of Mass Flow Meters and Controllers, including dimensions, weight, and flow ranges, are provided.

Conversion Factors
Conversion and viscosity factors are available for selecting appropriate models for gases other than air.

Compression Types
  • 55 1/2” OD compression type
  • 66 20 mm OD compression type
  • 88 1/4” Face seal male
  • 99 other


Mounting Between Flanges
  • 01: DIN PN10
  • 02: DIN PN16
  • 03: DIN PN40
  • 06: ANSI 150
  • 07: ANSI 300
  • 13: Flanged connection, DIN PN40
  • 26: Flanged connection, ANSI 150
  • 99: other


Internal Seals
  • V: FKM/Viton® (factory standard)
  • E: EPDM
  • K: FFKM/Kalrez®


Model Number Identification
F-101DI Mass Flow Meter, IP65 configuration
F-102E Mass Flow Meter, IP40 configuration

Company Overview
Bronkhorst High-Tech designs and manufactures innovative instruments and subsystems for low-flow measurement and control in laboratories, machinery, and industry. They offer a range of mass flow meters and controllers for gases and liquids, based on thermal, Coriolis, and ultrasonic measuring principles, with local support in over 40 countries.

Contact Information
Bronkhorst High-Tech B.V.
Nijverheidsstraat 1a
NL-7261 AK Ruurlo, The Netherlands
Tel. +31 573 458800
Email: [email protected]
Website: www.bronkhorst.com
See more

Catalog excerpts

LOW-ΔP-FLOW-1

LOW- P-FLOW Mass Flow Meters/Controllers for low pressure drop or corrosive gas service

 Open the catalog to page 1
LOW-ΔP-FLOW-2

Introduction Bronkhorst High-Tech B.V., the European market leader in thermal Mass Flow Meters/Controllers and Electronic Pressure Controllers, has more than 40 years experience in designing and manufacturing precise and reliable measurement and control devices. With a wide range of instruments, Bronkhorst offers innovative olutions for many different applications in s many different markets. The instruments are made to customers’ specification, in various styles, suitable for use in laboratory, industrial and hazardous areas, in such diverse applications as semiconductor and analytical installations,...

 Open the catalog to page 2
LOW-ΔP-FLOW-3

> Models and flow ranges (based on Air) Measurement / control system Accuracy (incl. linearity) ± 1% FS (of Full Scale) (based on actual calibration) Turndown 1 : 50 (2...100%) Settling time (controller) standard: 2,3 seconds Control stability < ±0,1% FS (typical for 1 ln/min N2) Operating temperature -10,+70°C for ATEX Cat. 3 0, 50°C Temperature sensitivity 0,1% FS/°C Pressure sensitivity 0,1% Rd/bar typical N2 Leak integrity tested < 2 x 10-9 mbar l/s He Mounting position horizontal Warm-up time 30 min. for optimum accuracy; Mechanical parts Material (wetted parts) stainless steel, other on...

 Open the catalog to page 3
LOW-ΔP-FLOW-4

IP40 Mass Flow Meter Dimensions subject to change without notice. For certified drawings and for dimensions of F-107Z series flanged type mass flow meters please contact factory.

 Open the catalog to page 4
LOW-ΔP-FLOW-5

To select the right model for other gases than Air, we have to carry out two calculations: conversion factor The highest flow rate calculated determines the flow capacity. Example: Freon-22, 1 ln/min Conversion factor = 0,49 (see table below) Viscosity factor = 0,34 (see table below) Highest flow rate = 2,94 ln/min so we can select model F-101E or F-101EI MFM resp. F-201EV or F-201EI MFC. viscosity factor > Conversion factors and viscosity factors Name ABC Name ABC Name ABC A = Symbol - B = conversion factor @ 20°C. I atm. - C = viscosity factor @ 20°C. I atm.

 Open the catalog to page 5
LOW-ΔP-FLOW-6

An interesting example to control a flow rate is using a LOW-AP-FLOW Mass Flow Meter in combination with a sampling pump. In this configuration the speed of the pump is controlled to obtain the required mass flow rate, determined by the setpoint value. Burner control using Mass Flow Controllers brings many advantages compared to conventional systems, where flow is adjusted through needle valves. When burner orifices get clogged or when gas supply pressure varies, an MFC will automatically adapt to the changed conditions. For the control of relatively large flows with low differential pressure,...

 Open the catalog to page 6
LOW-ΔP-FLOW-7

Connections (in/out) Valve only compression type couplings Pressure rating 1) Max. operating pressure: 10 bar Ranges See page 3 of this leaflet, 'Models and flow ranges. Model numbers F-106xD, F-107xD and ending with the letter "I" are IP65 rated. Other models are IP40 rated. C RS232 + POWERLINK (n/c control) D RS232 + DeviceNet™ (n/c control) E RS232 + DeviceNet™ (n/o control) J RS232 + EtherNet/IP (n/o control) K RS232 + CANopen® (n/c control) L RS232 + CANopen® (n/o control) M RS232 + Modbus (n/c control) N RS232 + Modbus (n/o control) O RS232 + POWERLINK (n/o control) P RS232 + PROFIBUS (n/c...

 Open the catalog to page 7
LOW-ΔP-FLOW-8

Bronkhorst High-Tech designs and manufactures innovative instruments and subsystems for low-flow measurement and control for use in laboratories, machinery and industry. Driven by a strong sense of sustainability and with many years of experience, we offer an extensive range of (mass) flow meters and controllers for gases and liquids, based on thermal, Coriolis and ultrasonic measuring principles. Our global sales and service network provides local support in more than 40 countries. Discover Bronkhorst®! Bronkhorst High-Tech B.V. Nijverheidsstraat 1a www.bronkhorst.com NL-7261 AK Ruurlo, The...

 Open the catalog to page 8

All Bronkhorst catalogs and technical brochures

  1. FLOW-SMS

    6  Pages

  2. EL-FLOW Base

    4  Pages

  3. METAL SEALED

    6  Pages

  4. IQ+FLOW

    6  Pages

  5. MASS-VIEW

    8  Pages

  6. BRIGHT

    4  Pages

  7. E-8000

    8  Pages

  8. MAG-VIEW

    3  Pages

  9. MANI-FLOW

    1  Page

  10. FLOW-ADJUST

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.