Emergency power generation

Emergency power generation

Emergency power generation

Product catalog summary
Overview: This document outlines the implementation of automatic emergency power supply systems for businesses in trade, craftsmanship, and industry. It emphasizes the necessity of a reliable power generator to ensure continuity during power outages.
Specifications: The power generators are available in both single- and three-phase versions, suitable for global use with various capacity levels. They meet the latest efficiency and engineering standards, offering fuel consumption-optimized solutions. The sound level is controlled at 70 or 65 dB(A) at 7 meters.
Components and Features: The system includes an engine and alternator with single bearing coupling, oil pump, integrated fuel tank, exhaust gas silencer, lead batteries, and antivibration mountings. It offers both manual and automatic control options, with alarms for high temperature and low oil pressure, and emergency stop buttons.
Control Systems:
  • Manual Control System: Requires personnel for operation, providing controls for starting, stopping, and monitoring the generator.
  • Automatic Control System: Suitable for unattended operations, it automatically starts and stops the genset during power failures and restorations, featuring a microprocessor-based control unit for precise monitoring.
Accessories and Options: Additional accessories include automatic fuel systems, earth fault relays, slow trailers, and remote control capabilities. Optional features are voltage control, differential protection, and frequency protection.
Compliance and Standards: The products comply with directives 2006/95/CE, 98/37/CE, and 89/336/CEE, ensuring adherence to international safety and performance standards.
Technical Data: Detailed technical specifications are provided, covering power output, sound levels, and optimal environmental conditions.
Microprocessor Control Unit: Features a three-digit display for measurements, alarms, messages, and errors, with buttons for mode selection, alarm reset, and start-stop functions. LEDs indicate mode, display, motor status, and power supply presence.
Display Measurements: Shows mains and generator voltages, generator frequency, battery voltage, and service hours.
Front Panel Devices: Includes a generator line ammeter and an acoustic alarm.
Auxiliary Services: Features an automatic battery charger limited to 2 A for voltage and current.
Power Circuit: Includes a four-pole automatic switch with a thermal-magnetic relay for protection, and a TN distribution system with telecommunication command consent.
Contact Information: Headquarters in Austria: BRODINGER IT-Security Technology, Bahnhofstrasse 9, AT-4843 Ampflwang im Hausruckwald. Phone: +43(0)7675 20121, Fax: +43(0)7675 20122. Support hotline: +43(0)810 00 17 34, Email: [email protected], Website: www.brodinger.at
See more

Catalog excerpts

Emergency power generation-1

Safety for trade, craftsmen & industry IT Security Technology for Your Business

 Open the catalog to page 1
Emergency power generation-2

n IT electric wiring in accordance with standard n Automatic emergency power circuits n Additional power supply with power generator n Uninterruptible voltage supplies Emergency power generationwith additional tank Supply units Automatic emergency power supply in the event of mains failure The power generator takes over power supply after only a few seconds, and switches back to the local utility company supply as soon as power returns to the grid. With our products, complete installation - including protection - is built into the power generator. Single-and three-phase versions are available....

 Open the catalog to page 2
Emergency power generation-3

Dati tecnici Allestimento • Motore ed alternatore in accoppiamento monoblocco • Pompa estrazione olio • Basamento • Sebatoio incorporato nel basamento • Marmitta dei gas di scarico all'interno della cofanatura • Indicazione riserva combustibile • Predisposizione per caricamento automatico del combustibile • Batteria/e al piombo • Supporti antivibranti • Quadro elettrico a bordo ingresso per l'avviamento e l'arresto MANUALE con: strumenti ed apparecchiature per il comando ed il controllo del motore e dell'alternatore e interruttore automatico quadripolare 3+N • Allarmi ed arresto motore per alta...

 Open the catalog to page 3
Emergency power generation-4

COMSUMP. BASED ON PRIME POWER MODEL LOAD ACCEP. (%) FUEL TANK (L) LIMITED TOTAL Tensione in uscita 400 V trifase; il valore di rumorosita e espresso in dB(A) ad una distanza di 7 m in campo libero. I prodotti sono conformi alle direttive 2006/95/CE, 98/37/CE e 89/336CEE. Nel territorio italiano i gruppi elettrogeni rispondono alla circolare n. 31 MI.SA (78) II e successive modifiche. Output voltage 400V; sound level is refer to dB(A) at 7 m in free condition. Our products comply with directives 2006/95/CE, 98/37/CE and 89/336/CEE. In the italian territory the gensets are according to the n. 31...

 Open the catalog to page 4
Emergency power generation-5

New Generation of Gen Sets QUADRO DI COMANDO MANUALE II sistema di comando manuale e indicato in tutti i casi dove la produzione di energia elettrica e necessaria per un periodo determinato e alla presenza di personale che puo effettuare la conduzione del gruppo elettrogeno stabilendo gli orari di attivazione dello stesso. Con il comando manuale l’attivazione deve essere effettuata necessariamente da un operatore. Il quadro manuale consente di effettuare i comandi di avviamento ed arresto del gruppo elettrogeno, la chiusura ed apertura dell’interruttore generale di alimentazione delle utenze...

 Open the catalog to page 5
Emergency power generation-6

New Generation of Gen Sets QUADRO DI COMANDO AUTOMATICO A MICROPROCESSORE II sistema di comando automatico e indicato in tutti i casi dove non e presente il personale che puo effettuare la conduzione del gruppo elettrogeno. Generalmente questo sistema viene impiegato per sopperire alla interruzione di alimentazione della fonte principale (generalmente da una rete pubblica) in tempi brevi o quando e necessario disporre di energia elettrica in determinate situaziuoni: per ridurre il prelievo di energia dalla rete pubblica o per alimentare sistemi di sicurezza che non possono essere alimentati dalla...

 Open the catalog to page 6
Emergency power generation-7

Headquarter Austria

 Open the catalog to page 7
Emergency power generation-8

BRODINGER IT-Security Technology Bahnhofstrasse 9 AT-4843 Ampflwang im Hausruckwald phone: +43(0)7675 20121 fax: +43(0)7675 20122 Support hotline (7x 24 h) +43(0)810 00 17 34 email: [email protected] l www.brodinger.at

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.