Catalog excerpts
Data Center Documentation Po HUAWGI Features Features Three-phase input three-phase output high-frequency tower-mounted UPS Ultra-wide input voltage range: 138-485 VAC 5 kA surge protection design and conformal coating, enabling high adaptation to harsh environment Efficiency up to 99% in ECO mode Output PF: 1, showing excellent loading capacity of the output • Ultra-wide input voltage range: 80-280 VAC • Super strong overload capability Output PF: 0.9, showing strong loading • capacity of the output • System efficiency up to 96% Ultra-wide input voltage range: 138-485 VAC Ultra-wide input frequency range: 40-70 Hz Efficiency up to 96%, reducing UPS power consumption by 50% Power density up to 300 kVA/rack Number of batteries adjustable within 30-44 • Ultra-wide input voltage range: 138-485 VAC • Redundancy design for control modules • Intelligent battery management • Supports intelligent hibernation • 7-inch LCD graphical display • Supports multiple communication modes Ultra-wide input voltage range: 138-485 VAC No derating at PF (inductive /capacitive) above 0.5 iPower fault warning function Efficiency up to 96% in online mode Real-time monitoring of power supply and distribution status Efficiency up to 96% at 40% load and up to 95% at 20% load in online mode High power density, saving 50% footprint and providing more space for IT equipment On-demand smooth capacity expansion (a single UPS can be expanded to 800 kVA) Real-time monitoring of power supply and distribution status Ultra-wide input voltage range: 138-485 VAC No derating at PF (inductive/capacitive) above 0.5 iPower fault warning function Efficiency up to 97% at 40% load and up to 96.5% at 20% load in online mode High power density, saving 50% footprint and providing more space for IT equipment Hot swap design for modules (hot-swappable bypass, power, and control modules) Supports tower- and rack-mounting Supports various optional monitoring cards Ultra-wide input voltage range: 80-280 VAC 5 kA surge protection design, reducing the failure rate High power density design, only 2 U high Number of batteries adjustable within 16-20 Ultra-wide input voltage range: 80-280 VAC 5 kA surge protection design, reducing the failure rate High power density design, only 3 U high Number of batteries adjustable within 32-40
Open the catalog to page 1Modular Data Center Series FusionModule2000 Smart Modular Data Center FusionModule800 Smart Small Data Center FusionModule500 Smart Mini Data Center High-integration design, which integrates all subsystems including cabinet, power supply and distribution, cooling, cabling, and management subsystems 2-24 cabinets supported by a single row in a module; 6-48 cabinets supported by dual rows in a single module Maximum IT power consumption up to 21 kW/rack Strong environmental adaptability; stable running within wide voltage, temperature, and load ranges Battery temperature detection and warning,...
Open the catalog to page 2All Brodinger IT-Sicherheitstechnik e.U. catalogs and technical brochures
-
ITSCEN1047-2, 20 foot container
31 Pages
-
Emergency power generation
8 Pages
-
FLOOR-STANDING CABINETS
18 Pages
-
IT climate control
56 Pages
-
IT security concepts
17 Pages