1. Catalogs
  2. Brodinger IT-Sicherheitstechnik e.U.
  3. 19‘‘ Cabinet gaseous fire suppression system

19‘‘ Cabinet gaseous fire suppression system

19‘‘ Cabinet gaseous fire suppression system

19‘‘ Cabinet gaseous fire suppression system

Product catalog summary
Application: The fire prevention system is designed for server, network, and telecommunication cabinets.
Advantages: The system offers self-assembly, compact design (3 HU), easy maintenance and operation, quick recovery post-release, and the ability to protect multiple cabinets with one system. The aerosol used is electrically non-conductive.
Options: Includes SNMP alarm, additional smoke detectors and extinguishing generators for larger areas, and generator-kits for easy restart.
Function: The system uses two smoke detectors to control the release of the gaseous fire suppression system. Upon detecting smoke, it enters a pre-alarm status, and if confirmed, it releases aerosol to extinguish the fire. The aerosol is non-toxic, environmentally friendly, and does not damage electrical equipment.
Comparison with NOVEC Systems: Aerosol systems do not require pressure tanks or overpressure flaps, have zero global warming and ozone depletion potential, and do not require refilling stations. They are non-toxic, non-corrosive, and maintain functionality for 20 years.
Article Table: Lists various items such as aerosol fire suppression systems, generator-kits, and smoke detectors, detailing their specifications and compatibility.
See more

Catalog excerpts

19‘‘ Cabinet gaseous fire suppression system-1

19'' Cabinet gaseous fire suppression systemFire prevention for server protection cabinets Application: ■ server cabinets ■ network cabinets ■ telecommunication cabinets Advantages: ■ self-assembly possible ■ compact design - only 3 HU ■ easy to maintain ■ easy to operate ■ easy recovery after release ■ solution for most of all cabinets ■ possible to protect several cabinets with only one fire suppression system ■ aerosol ist electrically non - conductive Options: ■ SNMP alarm ■ possibility to install more smoke detectors and extinguishing generators to increase the size ofthe save area ■ generator-kits for easy restart after release installation example Bahnhofstrasse 9 email: [email protected]

 Open the catalog to page 1
19‘‘ Cabinet gaseous fire suppression system-2

19'' Cabinet gaseous fire suppression systemFire prevention for server protection cabinets Function: Two smoke detectors control the automatic release of the gaseous fire suppression system. If one of the smoke detectors identify smoke, the system goes into pre-alarm status, showed by LED. If the second fire detector identify smoke, the system changes to main-alarm status and the extinguishing system starts to float the area with aerosol. During a short period of time, the aerosol stay inside the cabinet and will extinguish the fire immediately. Afterwards the cabinet can be opened and the aerosol...

 Open the catalog to page 2
19‘‘ Cabinet gaseous fire suppression system-3

Differences between AEROSOL and NOVEC extinguishing-systems: * Can be modified project-specifically ** Can be harmful Bahnhofstrasse 9 email: [email protected]

 Open the catalog to page 3
19‘‘ Cabinet gaseous fire suppression system-4

Server rack solution for 3 Cabinets Bahnhofstrasse 9 email: [email protected]

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.