Electronic Timers Data Sheets and Selection Guide Valid as of 1 March 2012

Open the catalog to page 1
Timer selection Guide - 2

Electronic Timers Introduction & Selection Guide INTRODUCTION The Brodersen timer programme includes both multifunction and singlefunction timers. The selection guide below will help to select the right application. Brodersen multifunction timers combine a range of timing functions which are easily selected on the front of the timer. The time range is also selectable on the front and the timer will work at any voltage from 10.5265V AC or DC In addition to the multifunction timers, Brodersen also manufacture a singlefunction timer. All timers are available in versions for DIN rail or 11pole...

Open the catalog to page 2
Timer selection Guide - 3

Electronic Timers Introduction & Selection Guide PROVEN TECHNOLOGY You will find Brodersen timers in equipment, control panels and machines all over the world. Over the last decade more than 1 million timers has been installed in various applications. And we are still one of the largest manufactures of electronic timers. That is what we call “Proven Techology”. Brodersen A/S - Islevdalvej 187 - DK-2610 Roedovre - Tel: +45 45 35 26 27 - Fax: +45 45 35 26 29 E-mail: sales@brodersen.com - www.brodersen.com 3

Open the catalog to page 3
Timer selection Guide - 4

Electronic Timers On Delay • On Pulse • Symmetrical Recycler XM DESCRIPTION OPERATION Multifunction timer with 4 functions and 4 time ranges. The function and the time range are selectable via 2 front mounted rotary switches. Time ranges: 0.6-6sec, 6-60sec, 0.6-6min, 6-60min. The time is adjustable on the timer front. The timer can directly be connected to the supply voltage in the range of 10.5-265V AC/DC. Single or double relay output with LED indication of energized relay. Intermittent flashing of LED indicating timing period (over 6 sec.). Versions available for DIN rail or 11-pole...

Open the catalog to page 4
Timer selection Guide - 5

Time ranges: 0.6-6sec, 6-60sec, 0.6-6min. 6-60min. Full linearity between the ranges is provided i.e. an adjustment made to a specific time in seconds will give the same time in minutes just by operating the range switch. Supply voltage above 50V. The installation (all terminals) must be carried out according to the safety regulations! The control input and the supply input must be connected to the same circuit (phase and main switch). The output relay may only be used in circuits made according to the safety regulations. Timer accuracy: Repeating accuracy: ± 0.5% at constant conditions....

Open the catalog to page 5
Timer selection Guide - 6

Electronic Timers Release Delay • On Pulse • Off Pulse • On-Off Pulse XW DESCRIPTION Multifunction timer with 5 functions and 4 time ranges. The function and the time range are selectable via 2 front mounted rotary switches. Time ranges: 0.6-6sec, 6-60sec, 0.6-6min, 6-60min. The time is adjustable on the timer front. The timer can directly be connected to the supply voltage in the range of 10.5-265V AC/DC. Single or double relay output with LED indication of energized relay. Intermittent flashing of LED indicating timing period (over 6 sec.). Versions available for DIN rail or 11-pole...

Open the catalog to page 6
Timer selection Guide - 7

Electronic Timers Release Delay • On Pulse • Off Pulse • On-Off Pulse XW TECHNICAL DATA WIRING DIAGRAMS Time ranges: 0.6-6sec, 6-60sec, 0.6-6min. 6-60min. Full linearity between the ranges is provided i.e. an adjustment made to a specific time in seconds will give the same time in minutes just by operating the range switch. Supply voltage above 50V. The installation (all terminals) must be carried out according to the safety regulations! The control input and the supply input must be connected to the same circuit (phase and main switch). The output relay may only be used in circuits made...

Open the catalog to page 7
Timer selection Guide - 8

Electronic Timers On Delay • Release delay • On Pulse • Symmetrical Recycler XMW DESCRIPTION Multifunction timer with 5 functions and 4 time ranges. The function and the time range are selectable via 2 front mounted rotary switches. The time ranges cover 0.6sec.-60min. or 0.6min.-60hrs. The time is adjustable on the timer front. The timer can directly be connected to the supply voltage in the range of 10.5-265V AC/DC. Single or double relay output with LED indication of energized relay. Intermittent flashing of LED indicating timing period (over 6 sec.). Versions available for DIN rail or...

Open the catalog to page 8
Timer selection Guide - 9

Electronic Timers On Delay • Release Delay • On Pulse • Symmetrical Recycler XMW Timer accuracy: Repeating accuracy: ± 0.5% at constant conditions. Setting accuracy: ± 10%. Temperature drift: Max. 0.15% per °C. Start pulse: Min. 30msec. Reset time: Max. 100msec. Input current (control switch): 3-5mA (max. 0.2A peak). SPDT or DPDT. 1) D1/S1: Max. 8A/240V AC 5) Min. 10mA/24VDC S2: Max. 5A/240V AC 5) Min. 100mA/24VDC Contact material: D1/S1: AgNi 0,15 S2: AgCdO Frequency: Max. 1000 operations per hour at max. load. Mechanical life time: Min. 10 x 106 operations. Electrical life time: Min....

Open the catalog to page 9
Timer selection Guide - 10

Electronic Timers Asymmetrical Recycler XT DESCRIPTION OPERATION Asymmetrical recycler with 2 functions and 4 time ranges. The function is selected by mounting a jumper and the time range is selectable via the front mounted rotary switch. The pulse and pause time ranges cover 0.6sec.-60min. or 0.6min.60hrs. Pulse and pause time are individually adjustable on the timer front.The timer can directly be connected to the supply voltage in the range of 10.5-265V AC/DC. Single or double relay output with LED indication of energized relay. Intermittent flashing of LED indicating timing period (over...

Open the catalog to page 10
Timer selection Guide - 11

Electronic Timers Asymmetrical Recycler XT TECHNICAL DATA WIRING DIAGRAMS Time ranges: Supply voltage above 50V. The installation (all terminals) must be carried out according to the safety regulations! The control input and the supply input must be connected to the same circuit (phase and main switch). The output relay may only be used in circuits made according to the safety regulations. Code Time ranges 0.6-6sec.6-60sec.0.6-6min. 6-60min. H 0.6-6min. 6-60min.0.6-6hrs. 6-60hrs. Full linearity between the ranges is provided i.e. an adjustment made to a specific time in seconds will give...

Open the catalog to page 11

All Brodersen Systems catalogs and technical brochures

  1. RTU32s

    8 Pages

  2. RTU32 Brochure

    13 Pages

  3. Analog-PSTN

    4 Pages

  4. GC-10

    2 Pages

  5. RTU-COM

    22 Pages

  6. RTU8

    23 Pages

  7. RTU870

    18 Pages