Group: Brodersen
Catalog excerpts
DESCRIPTION Digital panel controller with 4-digit LED display. The panel controller is used for control and measurement of: • aC/DC voltage. • AC/DC current. •Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. The temperature measurement is fully linearized by the built-in microprocessor. • Standard process signals. The actual input signal type and measuring range must be specified when the panel controller is ordered. Splash proof front panel with integrated display, LED indicators and 4 button keypad for programming and adjustment. The panel controller is microprocessor based and fully programmable from the keypad: • Output relay mode selection with 6 different output modes. • Scale minimum/maximum. • Decimal point position. • Setpoint (1 or 2). • Hysteresis (below or above setpoint). • Correction of read-out (in case of deviation between actual measuring value and read-out). • Display update time (0-10.0 sec.). • On delay, output relay 1 & 2 individually (0-100.0 sec.). • Release delay, output relay 1 & 2 individually (0-100.0 sec.). The settings are stored in an EEPROM and accidental change of preprogrammed settings is avoided through the keyboard lock facility. One or two output relays (UDC-32) with LED indication of energized relay. Standardized housing (96 x 48 mm) with plug-in terminals at the rear. Versions with galvanic isolation between input signal and power supply. REAR PANEL/CONNECTIONS Rear panel Supply voltage DC OUTPUT RELAY MODES The two output relays can be programmed to perform one of 6 functions*). Mode Function Application example A1 Two level heater Relay 1: High level. Relay 2: Basic level. 2 separate setpoints. Two level indicator Relay 1: Level 1. Relay 2: Level 2. 2 separate setpoints. Alarm Relay 1: Lower limit. Relay 2: Upper limit. 2 separate setpoints. Heating/cooling Relay 1: Controls heating. Relay 2: Controls cooling. Common setpoint. Heating/alarm Relay 1: Controls heating. Relay 2: Alarm low and highlimit. Common setpoint. Cooling/alarm Relay 1: Controls cooling Relay 2:Alarm low and high limit. Common setpoint. E Mail: bc@brodsencontrols.com www: www.brodersencontrols.com
Open the catalog to page 1VERSION/ORDERING CODES Type: Output relay: 2 output relays. Standard process signals: 3) 0-20mA DC/0-10V DC U1 Digital Panel Meters & Controllers Digital Panel Controllers UDC-32 TECHNICAL DATA Hysteresis: Adjustable inside the defined scale, above Display: Digit height: Update time: Scale: 4 digit LED-type (-1999 to 9999). 14 mm. Programmable 0-10sec, 0.1sec. resolution. Programmable scale min. and max. within the limits of the display (-1999 to 9999). Decimal point: Programmable _._____._ _ Indicators: S1/S2 (green): Output relay activated. Output relay: UDC-32: 2 SPDT. Mechanical...
Open the catalog to page 2AC/DC VOLTAGE DESCRIPTION Input for direct measurement of AC or DC voltages up to 500V. The AC input is equipped with a true RMS rectifier for accurate ACmeasurement. The facilities of the UDC-32 with two setpoints and output relays with programmable time delay and hysteresis make the UDC-32 suited for advanced voltage monitoring and control. Typical applications: Monitoring and alarm systems (over/undervoltage). Generator control systems. Battery charge control. Battery monitoring and control in power back-up systems. AC/DC CURRENT DESCRIPTION Input for direct measurement of AC or DC...
Open the catalog to page 3TEMPERATURE DESCRIPTION Input for all types of temperature sensors, both thermocouples and resistor types. High measuring accuracy is obtained over a wide temperature range by the microprocessor's compensation for nonlinearity in the sensor signal. The two output relays and the extensive programming facilities make the UDC-32 suitable for most temperature control and monitoring applications. Typical applications: General temperature control and monitoring applications. Wide range temperature measurement with high accuracy. Temperature with separate control and alarm output. STANDARD PROCESS...
Open the catalog to page 4All Brodersen Controls catalogs and technical brochures
-
UDC-35
4 Pages
-
Signal Converters & Isolators
19 Pages
-
Power Supplies
3 Pages
-
Operator Interfaces
12 Pages
-
Power Supplies
8 Pages
-
PX Signal Converters
6 Pages
-
igital timer eliro
3 Pages
-
control & monitoring relays
35 Pages
Archived catalogs
-
Data Radios Data Sheet
32 Pages
-
Data Radios Sales Brochure
4 Pages
-
X Timer data Sheet
31 Pages
-
Data Radios Sales Brochure
4 Pages
-
RTU870 Selection Guide
6 Pages
-
RTU870 Data Sheet
39 Pages
-
RTU32 Data sheet
9 Pages
-
RTU Overview Brochure
2 Pages
-
RTU32 Sales Brochure
8 Pages