Selection Guide Threshold relays Process signal converters/isolators Temperature converters Process signal to pulse frequency converters/isolators Pulse frequency to process signal converters/isolators Resistance to process signal converters/isolators Current to process signal converters/isolators Programmable transmitters/isolators
Open the catalog to page 1Selection Guide 0-5V DC 0-10V DC -10 - +10V DC 0-20mA DC 4-20mA DC Selected via switch on the front panel. Impedance (V): Approx. 100 kOhm Impedance (I): 50 Ohm Upper frequency limit: 30Hz 0-5V DC 0-10V DC -10 - +10V DC 0-20mA DC 4-20mA DC Selected via switch on the front panel. Impedance (V): Approx. 100 kOhm Impedance (I): 50 Ohm Upper frequency limit: 30Hz 0-5V DC 0-10V DC -10 - +10VDC 0-20mA DC 4-20mA DC Selected via switch on the front panel. Impedance (V): Approx. 100 kOhm Impedance (I): 50 Ohm Upper frequency limit: 30Hz Threshold relay for process signal. Relay output. Adjustable setpoint...
Open the catalog to page 2-50-100°C -50-300°C Selected via terminals. Temperature drift < 0.05%/°C 0-5V DC 0-10V DC -10 - +10V DC 0-20mA DC 4-20mA DC Selected via switch on the front panel. Impedance (V): Approx. 1 MOhm Impedance (I): 50 Ohm 0-100Hz 0-500Hz 0-1000Hz 0-2000Hz 0-5000Hz Selected via switch on the front panel. Internal supply for sensors (max. 10mA). Conversion of signal from 2/3-wire Pt-100 or Pt-1000 probe. -50-300oC in two ranges. Offset/gain (zero/span) adjustable on the front panel: ± 5%. Output selection via choice of terminals. 4-20mA DC (max. 500 Ohm) 0-20mA DC (max. 500 Ohm) 0-10V DC (via internal...
Open the catalog to page 3Resistance to analogue converter for the conversion of a resistance to an analogue process signal with galvanic isolation. A typical apllication would be to convert a resistor probe to an anlogue input of a PLC and provide galvanic isolation between input and output. Signal converter for the conversion of an AC current signal to an analogue process signal. A typical application would be to convert a signal from a Current Transformator measuring high current to an analogue input of a PLC. Mechanical Dimensions Side 0-5kOhm 0-1kOhm Selected via coding between terminals. 0-1A AC 0-5A AC Selected...
Open the catalog to page 4The BRODERSEN group has for more than 30 years supplied industrial process components including remote outstations, data loggers and communication modules for the process and automation industry. Germany: Brodersen Automation GmbH Düsseldorfer Str. 138 D-45481 Mülheim a. d. Ruhr Tel.: +49 (208) 46954-0 Fax: +49 (208) 46954-50 [email protected] www.brodersen.de United Kingdom: Brodersen Control Systems Ltd. Canbury Business Park, Unit 11 Elm Crescent, Kingston upon Thames Surrey KT2 6HJ Tel.: +44 (0) 20 8546 4283 Fax: +44 (0) 20 8547 3628 [email protected] www.brodersen.co.uk