Operator Interfaces-1

Operator Interfaces Introduction & Selection Guide Operator panels are supplied with different options for connection to the controller - e.g. with a parallel interface for direct connection to the digital outputs on the controller, with a serial interface including drivers to most PLCs or with VT100 terminal emulation. Programming of texts is perfectly straightforward and is done either with an ordinary PC or by connecting a PC keyboard directly. If display message printouts including the time are required for documentation or data-logging purposes, a printer can be connected. Printer output Acoustic alert Variable digits As and where desired, the operator can key his way directly into the PLC and change parameters or implement pre-programmed functions - and here it is possible to choose between panels with 4 or 24 keys. Serial interface The information is transferred from a PLC or other controller and converted to clear, simple messages on the display - as fixed texts or a combination of fixed text and current measured variable. Operator panels have 2 lines of text with 20 characters and a capacity of up to 200 messages. Each message can include up to 16 dynamic digits. Parallel interface Brodersen message displays and operator panels provide the operator with relevant information about e.g. operating conditions and actual measured variables, when the plant is operating normally, and alerts the operator in case of a malfunction situation. Real-time clock & calendar SELECTION GUIDE The elegant design and small dimensions of the Brodersen message displays have been tailor-made for incorporation in a console or control panel. Brodersen also manufactures message displays and operator panels with BITBUS™ interface and industrial PCs.

 Open the catalog to page 1
Operator Interfaces-2

Operator Interfaces VT100 Terminal Emulation REAR PANEL/CONNECTIONS UCT-33/36 message display and operator panel is compatible with a VT100 terminal. Due to physical and functional limitations only a subset of the VT100 control commands are applicable to this device. UCT-33/36 can be used as a nonintelligent man machine interface in industrial installations. The display acts as an output device for a "host", e.g. a PLC or a computer - data coming from the host is displayed on the screen. Simultaneously the keypad can be used as an input device to the host - information entered through the keyboard...

 Open the catalog to page 2
Operator Interfaces-3

UCT-33: 4 keys. UCT-36: 24 keys. Tactile feedback type. Acoustic feedback selectable EIA, RS 232C. Full duplex. 300, 1200, 2400, 4800, 9600 Baud. ASCII. Asynchronous. 7 or 8 bit. Even, odd or none. XON / XOFF. Subset of VT100 (ANSI) 9-pole sub-D (male). 12-48VAC/DC(10.5-58V). 110-240V AC (90-265V). Plug-in screw terminals. Mains frequency: Supply voltage: Serial interface: Mode: Speed: Code: Format: Character size: Parity: Synchronization: Control: Connector: Display field: Height of characters: Intensity: VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. 125 x...

 Open the catalog to page 3
Operator Interfaces-4

Operator Interfaces Parallel Interface UCT-30 REAR PANEL/CONNECTIONS General purpose message display for front panel mounting with up to 100 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. The message display can easily be integrated into any PLC controlled system as the message selection is controlled by 9 (or less) standard outputs on the PLC. Versions available for direct mains supply or battery supply. Parallel inputs, plug-in screw terminals. Code switch. Connector for external keyboard or PC. Fuse. Mains supply, plug-in screw terminals. Ground...

 Open the catalog to page 4
Operator Interfaces-5

Up to 100 messages. 40 characters each. Messages are selected by an 8 bit binary co-de at the parallel input. Messages are stored in a built-in memory (EEPROM) independent of supply voltage. 9 optocoupled inputs, PNP, NPN or relay controllable. 10-30V DC (active). Max. 3V DC (non active). 12V DC: Typically 3mA. 24V DC: Typically 6mA. Typically 1ms (noise suppression). 12V DC nom. max. 100mA. Plug-in screw terminals. Input delay: Built-in DC supply: Connector: Programming: RS232C format: Connector: Supply voltage: Connector: Standard XT/AT-compatible keyboards or PC via RS232C. 1200 Baud, ASCII,...

 Open the catalog to page 5
Operator Interfaces-6

Operator Interfaces Parallel Interface UCT-31/31P REAR PANEL/CONNECTIONS General purpose message display for front panel mounting with up to 200 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. Process values, counter values, etc. with up to 16 digits can be placed in the text field. The message display can easily be integrated into any PLC controlled system as the message selection and read-out of process values is controlled by 9 (or less) standard transistor outputs on the PLC. The UCT-31P version can be connected to a standard parallel printer and...

 Open the catalog to page 6
Operator Interfaces-7

VFD type, 2 x 20 characters, 5 x 7 dot matrix. Readable at a distance up to 3 m. Standard XT/AT-compatible keyboards or PC via RS232C. 1200 Baud, ASCII, 1 start bit, 8 bit, no parity, 1 stop bit. 7-pole female DIN connector (XT/AT compatible). Supply voltage: Messages: Up to 200 messages (P-version: 190). 40 characters each. Messages are selected by an 8 bit binary code at the parallel input (100 messages using BCD selection). Messages are stored in built-in memory (EEPROM) independent of supply voltage. 12-48V AC/DC (10.5-58V). 110-240V AC (90-265V). Plug-in screw terminals. Mains frequency:...

 Open the catalog to page 7
Operator Interfaces-8

Operator Interfaces Parallel Interface UCT-35/35P REAR PANEL/CONNECTIONS General purpose message display for front panel mounting with up to 200 prestored messages. Each message contains 2 lines of text with up to 20 characters per line. Process values, counter values, etc. with up to 16 digits can be placed in the text field. The message display can easily be integrated into any PLC controlled system as the message selection and read-out of process values is controlled by 9 (or less) standard transistor outputs on the PLC. 4 button keypad on the front with direct connection to the rear connector...