Group: Brodersen
Catalog excerpts
Digital Panel Meters & Controllers Introduction & Selection Guide INTRODUCTION Brodersen digital panel meters and controllers provide clear and accurate display of process values, easily readable at a distance. The digital panel meters and controllers accept a great variety of input signals, thus applicable in most applications. For applications including control both on/off, P, PD, PI and PID controllers are available within the product programme. UDM-20 Digital panel meter UDC-32 Digital panel controller UDC-35 Digital panel controller UDM-10 Digital panel meter The compact design, the ease of adjustment and the consistent quality of the entire range of Brodersen products are the hallmarks of a truly unique product programme. Remark H x B: 24 x 48 mm H x B: 48 x 96 mm On/off controller H x B 48x96 Prog. On/off, P, PI, PD, PID contr. Standard process signals Digital panel meters and controllers AC/DC current Output relays AC/DC voltage SELECTION GUIDE
Open the catalog to page 1Digital Panel Meters & Controllers Digital Panel Meter UDM-10 Digital panel meter with 3½-digit LED display. The panel meter for monitoring of standard process signals is fully user adjustable within in the scale limits -1999 to 1999 with a maximum span of 2000 steps, e.g. a scale from -1000 to 1000. The panel meter is used for monitoring and measurement of: • AC/DC voltage. • AC/DC current. • Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. • Standard process signals. The actual input signal type and measuring range must be specified when the panel meter is ordered....
Open the catalog to page 2TECHNICAL DATA Protection: Front: Rear: Dimensions: Front: Cut-out: Depth: According to DIN 43700. 48 x 24 mm. 43.5 x 21.5 mm. 80 mm + frame 5 mm + terminals 10mm. Housing: Front: House: Plastic. Self-extinguishing ABS. Approx. 85 g. 1) With external shunt (60mV voltage drop) type AAS-010 (0-10.0 A DC) or AAS-100 (0-100 A DC). 2) There is no galvanic isolation between input and supply. External isolation should be provided to prevent damage to the meter when measuring voltage/current or a G24-version with internal isolation should be used. 3) Special range. Please specify input and scale....
Open the catalog to page 3Digital Panel Meters & Controllers Digital Panel Meter UDM-10 AC/DC VOLTAGE AC/DC CURRENT Input for direct measurement of AC or DC voltages up to 100V. The AC input is equipped with a full wave rectifier for accurate AC measurement. The scale of the panel meter is adjusted to the actual measuring range. Input for direct measurement of AC or DC current up to 200mA DC/ AC The measuring range is easily extended by adapting an external shunt. The AC input is equipped with a full wave rectifier for accurate AC measurement. The scale of the panel meter is adjusted to the actual measuring range....
Open the catalog to page 4Digital Panel Meters & Controllers Digital Panel Meter UDM-10 Input for all types of temperature sensors, both thermocouples and resistor types, makes the UDM-10 suitable for most temperature moni-toring applications. The scale of the panel meter is adjusted to the actual measuring range. The scaling facilities of the UDM-10 makes it ideal as a monitor device for normal standard process signals, e.g. 4-20mA. Any output from a transmitter can be scaled to engineering units and a unit label can be inserted on front of the panel meter. A sheet with common units is enclosed with the panel...
Open the catalog to page 5Digital Panel Meters & Controllers Digital Panel Meter UDM-20 Digital panel meter with 3½-digit LED display. The panel meter is used for monitoring and measurement of: • AC/DC voltage. • AC/DC current. • Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. • Standard process signals. The actual input signal type and measuring range must be specified when the panel meter is ordered. Splash proof front panel with integrated display in standardized housing (96 x 48 mm) with plug-in terminals at the rear of the panel meter. Versions with galvanic isolation between input...
Open the catalog to page 6Display: Digit height: The scale is adjusted to the actual measuring range listed in the order ing key, except U1 version with user adjustable scale (-1999 to 1999, max. 2000 steps). Selectable 1.5 mm2 plug-in screw terminals. Supply voltage: Mains frequency: Protection: Front: Rear: Ambient temperature: Isolation: AC supply voltage versions: 12, 24, 48 V d.c: Dimensions: Front: Cut-out: Depth: mm. 4kV AC according to EN 60950 class II. 500V. According to DIN 43700. 96 x 48 mm. 91 x 43 mm. 88 mm + frame 7 mm + terminals 10 Housing: Front: House: 1) With external shunt (60mV voltage drop)...
Open the catalog to page 7Digital Panel Meters & Controllers Digital Panel Meter UDM-20 AC/DC VOLTAGE AC/DC CURRENT Input for direct measurement of AC or DC voltages up to 500V. The AC input is equipped with a full wave rectifier for accurate AC measurement. The scale of the panel meter is adjusted to the actual measuring range. Input for direct measurement of AC or DC current up to 200mA DC or 5A AC The measuring range is easily extended by adapting an external shunt or current transformer. The AC input is equipped with a full wave rectifier for accurate AC measurement. The scale of the panel meter is adjusted to...
Open the catalog to page 8STANDARD PROCESS SIGNAL Input for all types of temperature sensors, both thermocouples and resistor types, makes the UDM-20 suitable for most temperature moni-toring applications. The scale of the panel meter is adjusted to the actual measuring range. The scaling facilities of the UDM-20 makes it ideal as a monitor device for normal standard process signals, e.g. 4-20mA. Any output from a transmitter can be scaled to engineering units and a unit label can be inserted on front of the panel meter. A sheet with common units is enclosed with the panel meter. Typical applications: General...
Open the catalog to page 9Digital Panel Meters & Controllers Digital Panel Controller UDC-32 OUTPUT RELAY MODES Digital panel controller with 4-digit LED display. The two output relays can be programmed to perform one of 6 functions*). The panel controller is used for control and measurement of: • AC/DC voltage. • AC/DC current. •Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. The temperature measurement is fully linearized by the built-in microprocessor. • Standard process signals. The actual input signal type and measuring range must be specified when the panel controller is ordered....
Open the catalog to page 10All Brodersen Controls catalogs and technical brochures
-
UDC-32
4 Pages
-
UDC-35
4 Pages
-
Signal Converters & Isolators
19 Pages
-
Power Supplies
3 Pages
-
Operator Interfaces
12 Pages
-
Power Supplies
8 Pages
-
PX Signal Converters
6 Pages
-
igital timer eliro
3 Pages
-
control & monitoring relays
35 Pages
Archived catalogs
-
Data Radios Data Sheet
32 Pages
-
Data Radios Sales Brochure
4 Pages
-
X Timer data Sheet
31 Pages
-
Data Radios Sales Brochure
4 Pages
-
RTU870 Selection Guide
6 Pages
-
RTU870 Data Sheet
39 Pages
-
RTU32 Data sheet
9 Pages
-
RTU Overview Brochure
2 Pages
-
RTU32 Sales Brochure
8 Pages