INTRODUCTION Brodersen digital panel meters and controllers provide clear and accurate display of process values, easily readable at a distance. The digital panel meters and controllers accept a great variety of input signals, thus applicable in most applications. For applications including control both on/off, P, PD, PI and PID controllers are available within the product programme. The compact design, the ease of adjustment and the consistent quality of the entire range of Brodersen products are the hallmarks of a truly unique product programme. ■oaiNi I or-iAian I oz-iAian I ze-oan I se-oan SELECTION GUIDE E Mail: bc@brodsencontrols.com www: www.brodersencontrols.com
Open the catalog to page 1CALIBRATION/CONFIGURATION Minimum display read-out -1999 Digital panel meter with 3%-digit LED display. The panel meter is used for monitoring and measurement of: • AC/dC voltage. • AC/DC current. • Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. • Standard process signals. The actual input signal type and measuring range must be specified when the panel meter is ordered. Splash proof front panel with integrated display in standardized housing (48 x 24 mm) with plug-in terminals at the rear of the panel meter. Version with galvanic isolation between input signal and...
Open the catalog to page 2VERSION/ORDERING CODES Supply voltage: 12-24V AC/DC G24 Digital Panel Meters & Controllers Digital Panel Meter UDM-10 TECHNICAL DATA Temperature drift: Display: Digit height: Decimal point: Terminals: Supply voltage: Mains frequency: Consumption: G24 version: The scale is adjusted to the actual measuringrange listed in the order ing key, except U1 version with user adjustable scale (-1999 to 1999, max. 2000 steps). Selectable ______.. Protection: Front: IP54 (IP65 on request). Dimensions: Front: Cut-out: Depth: According to DIN 43700. 48 x 24 mm. 43.5 x 21.5 mm. 80 mm + frame 5 mm +...
Open the catalog to page 3AC/DC VOLTAGE DESCRIPTION Input for direct measurement of AC or DC voltages up to 100V. The AC input is equipped with a full wave rectifier for accurate AC measurement. The scale of the panel meter is adjusted to the actual measuring range. Typical applications: Monitoring systems (over/undervoltage). Generator monitoring systems. Battery charge monitor. Battery monitoring in power back-up systems. AC/DC CURRENT DESCRIPTION Input for direct measurement of AC or DC current up to 200mA DC/ AC The measuring range is easily extended by adapting an external shunt. The AC input is equipped with a...
Open the catalog to page 4TEMPERATURE DESCRIPTION Input for all types of temperature sensors, both thermocouples and resistor types, makes the UDM-10 suitable for most temperature moni-toring applications. The scale of the panel meter is adjusted to the actual measuring range. Typical applications: General temperature monitoring. Measuring accuracy: RTD/thermistor: 0.1% of full scale ±1 digit. Thermocouples: 1% of full scale ±1 digit 4). STANDARD PROCESS SIGNAL DESCRIPTION The scaling facilities of the UDM-10 makes it ideal as a monitor device for normal standard process signals, e.g. 4-20mA. Any output from a...
Open the catalog to page 5CALIBRATION/CONFIGURATION Minimum display read-out -1999 Digital panel meter with 3%-digit LED display. The panel meter is used for monitoring and measurement of: • AC/dC voltage. • AC/DC current. • Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. • Standard process signals. The actual input signal type and measuring range must be specified when the panel meter is ordered. Splash proof front panel with integrated display in standardized housing (96 x 48 mm) with plug-in terminals at the rear of the panel meter. Versions with galvanic isolation between input signal...
Open the catalog to page 6VERSION/ORDERING CODES Standard process signals U: 3) 0-20mA/4-20mA DC and 0-10V/2-10V DC U1 Digital Panel Meters & Controllers Digital Panel Meter UDM-20 TECHNICAL DATA Temperature drift: Display: Digit height: Scale: Decimal point: Max. 0.01% per °C. 3% -digit LED-type (-1999 to 1999). 14 mm. The scale is adjusted to the actual measuring range listed in the order ing key, except U1 version with user adjustable scale (-1999 to 1999, max. 2000 steps). Selectable ____ _______ Terminals: Supply voltage: Mains frequency: Consumption: Protection: Front: Rear: Ambient temperature: Isolation: AC...
Open the catalog to page 7AC/DC VOLTAGE DESCRIPTION Input for direct measurement of AC or DC voltages up to 500V. The AC input is equipped with a full wave rectifier for accurate AC measurement. The scale of the panel meter is adjusted to the actual measuring range. Typical applications: Monitoring systems (over/undervoltage). Generator monitoring systems. Batterry charge monitor. Battery monitoring in power back-up systems. AC/DC CURRENT DESCRIPTION Input for direct measurement of AC or DC current up to 200mA DC or 5A AC The measuring range is easily extended by adapting an external shunt or current transformer....
Open the catalog to page 8TEMPERATURE DESCRIPTION Input for all types of temperature sensors, both thermocouples and resistor types, makes the UDM-20 suitable for most temperature moni-toring applications. The scale of the panel meter is adjusted to the actual measuring range. Typical applications: General temperature monitoring. Measuring accuracy: RTD/thermistor: 0.1% of full scale ±1 digit. Thermocouples: 1% of full scale ±1 digit 4). STANDARD PROCESS SIGNAL DESCRIPTION The scaling facilities of the UDM-20 makes it ideal as a monitor device for normal standard process signals, e.g. 4-20mA. Any output from a...
Open the catalog to page 9DESCRIPTION Digital panel controller with 4-digit LED display. The panel controller is used for control and measurement of: • aC/DC voltage. • AC/DC current. •Temperature with Pt-100/500/1000, Ni-100, thermistors and thermocouples. The temperature measurement is fully linearized by the built-in microprocessor. • Standard process signals. The actual input signal type and measuring range must be specified when the panel controller is ordered. Splash proof front panel with integrated display, LED indicators and 4 button keypad for programming and adjustment. The panel controller is...
Open the catalog to page 10All Brodersen Controls catalogs and technical brochures
-
UDC-32
4 Pages
-
UDC-35
4 Pages
-
Signal Converters & Isolators
19 Pages
-
Power Supplies
3 Pages
-
Operator Interfaces
12 Pages
-
Power Supplies
8 Pages
-
PX Signal Converters
6 Pages
-
igital timer eliro
3 Pages
-
control & monitoring relays
35 Pages
Archived catalogs
-
Data Radios Data Sheet
32 Pages
-
Data Radios Sales Brochure
4 Pages
-
X Timer data Sheet
31 Pages
-
Data Radios Sales Brochure
4 Pages
-
RTU870 Selection Guide
6 Pages
-
RTU870 Data Sheet
39 Pages
-
RTU32 Data sheet
9 Pages
-
RTU Overview Brochure
2 Pages
-
RTU32 Sales Brochure
8 Pages