The document provides detailed information about the DHCX Hazardous-Area Rated Drum Heater, designed for use in T3 and T4A environments. It includes specifications, ordering information, and safety ratings.

Ordering Information:
The product can be ordered without a controlling thermostat and pilot light by replacing 'C' with 'N' in the part number. External control is required for this option.

Specifications:
  • 8” (203mm) wide band with a high-limit thermostat to maintain temperatures below NEC article 500 T-rating.
  • Power density of 2.5 Watts/in² (.004 Watts/mm²).
  • Patented grounded heating element laminated between layers of fiberglass reinforced silicone rubber.
  • Nominal silicone rubber density of 26 oz/yd² (881 grams/m²) per layer.
  • Attached adjustable dual set-point NEMA 7 temperature controller with a 6-foot (1.8m) power cord.
  • Maximum exposure temperature on the heating surface is 400°F (204°C).
  • Designed for metal drums with exceptional durability and flexibility.

Safety and Ratings:
  • Hazardous-area rated with a dual set-point NEMA 7 temperature controller connected to a high temperature limit indicator light.
  • Grounded heating element meets NEC 427.23 standards.
  • FM Approved for Class I Division 2 Groups A*, B, C, and D, and Class II Division 2, Groups F and G.

Temperature Ratings:
  • T3: NEC Temperature 392°F (200°C), Actual High Limit Thermostat 292°F (145°C).
  • T4A: NEC Temperature 248°F (120°C), Actual High Limit Thermostat 158°F (70°C).

Contact Information:
For more information, contact BriskHeat at 800-848-7673 or visit www.BriskHeat.com.
See more

Catalog excerpts

DHCX Hazardous-Area Rated Drum Heater-1

Your Heating Specialist since 1949 Product Highlights Hazardous-area rated Dual set-point NEMA 7 temperature controller connected to a high temperature limit indicator light Class I Division 2 Groups A*, B, C, and D Class II Division 2, Groups F and G Extra wide 8” (203mm) coverage area CONTAINER HEATERS DHCX Hazardous-Area Rated Drum Heater Exceptional durability and flexibility Grounded heating element meets NEC 427.23 Designed for metal drums * only for drum heater without NEMA 7 temperature controller • 8” (203mm) wide band • High-limit thermostat designed to keep blanket below NEC article 500 T-rating T Rating Actual High Limit Thermostat • Power density of 2.5 Watts/in2 (.004 Watts/mm2) • Patented grounded heating element • Heating element is laminated between two layers of 23 mil and two layers of 25 mil fiberglass reinforced silicone rubber • Nominal silicone rubber density of 26 oz/yd2 (881 grams/m2) per layer • Attached adjustable dual set-point NEMA 7 temperature controller with a 6-foot (1.8m) long power cord. One set-point is set at a high temperature limit and connected to a red indicator light. Moisture and chemical resistant • Blanket leads 6-foot (1.8m) long for NEMA7 controller; 1-foot (0.3m) without controller • Leads from blanket to controller are enclosed in a liquid tight conduit • 400°F (204°C) maximum exposure temperature on heating surface NEMA 7 Controller and High Temperature Limit Indicator Light Ordering Information: For T3 Environments Gallon (Liter) Size Total Wattage For T4A Environments Gallon (Liter) Size Total Wattage Ordering Option: Without controlling thermostat and pilot light. Replace “C” with “N” in part number. External control is required with this option. Toll Free: 800-848-7673 Phone: 614-294-3376 w w w .BriskHeat. c o m