Overview: The Five-step Voltage Controller ZEC2 is designed to manage the speed of ventilators with electronically commutated motors (EC) or other devices that utilize a 0-10VDC control signal. It requires a power supply of 10-12VDC/10mA, which is commonly available on EC drivers.
Specifications: The controller outputs a 5-step 0-10VDC signal, adjustable via a 6-position switch. The '0' position disables the control output. An 'Offset' function allows voltage adjustment by approximately 2.5V ±20% at the fifth step, with decreasing adjustments for lower steps. The device includes an LED indicator to signal operation and has a protection grade of IP54.
Compliance: The controller is manufactured in accordance with EN61000-6-2 and EN61000-6-3 standards.
Technical Details: The controller includes a 2.5kOhm ±20% potentiometer and operates with a power supply of 230V at 50/60Hz. A wiring diagram is provided for installation guidance.
Manufacturer Information: Breve Tufvassons, located at ul. Postępowa 25/27, 93-347 Łódź, Poland, reserves the right to modify the parameters due to ongoing development and changes in technical requirements. Contact details include phone: (42) 640-15-39, fax: (42) 640-15-41, and email: [email protected].
Five-step voltage controller Power supply: Potentiometer: Controller designed to control the speed of ventilators equipped with electronically commutated motors (EC) or other devices controlled by 0-10VDC signal. Required power supply is 10-12VDC/10mA, which is available on most of EC drivers. The output is 5-step 0-10VDC signal, which is controlled by 6-position switch. “0” position turns off control output. “Offset” function allows to change the level of voltage down approximately 2,5V +-20% for fifth step, decreasing for lower steps. LED diode signalizes operation of controller. Protection grade: IP54. Manufactured in compliance with: EN61000-6-2, EN61000-6-3. WIRING DIAGRAM OFFSET ul. Postępowa 25/27, 93-347 Łódź, Poland tel. (42) 640-15-39, fax: (42) 640-15-41 [email protected], www.brevetrafo.com Due to the constant development of the construction and changes in technical requirements, Breve Tufvassons reserves the right to change the above pa
Open the catalog to page 11 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page