GENERAL CATALOGUE
Open the catalog to page 3QUALITY MAKES OUR PRODUCTS GREAT Bremas is a recognized specialist in the development and production of high-quality components for photovoltaic applications. With a strong focus on innovation and performance, Bremas offers a complete range of products designed to meet the demanding needs of the renewable energy sector. The company has invested significantly in research and development over the years, which has led to the creation of numerous patents and innovative solutions. Our company is managed in full accordance with UNI EN ISO 9001, ISO 14001 and all our products are verified in our laboratory...
Open the catalog to page 5SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems STRING BOXES DC DISCONNECT SWITCHES DC switches up to 1500 Vdc 30A and 1000 Vdc 60A PV1 SURGE PROTECTIVE DEVICES DC and AC SPDs FUSE HOLDER DC fuse holders 1000 Vdc Residual Current Breaker with Overcurrent
Open the catalog to page 7SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems
Open the catalog to page 9Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN The SOLAR GUARDIAN has been especially developed as a safety device for direct current (DC) photovoltaic installations. The DC switch is used to disconnect the connected strings of the installation in case of an emergency situation (for example in case of fire or overheating). In case of AC line interruption of the building, the SOLAR GUARDIAN automatically shutdowns the DC lines of the PV system thanks to the electronic board. The DC disconnect switch(es) is(are) automatically turned OFF if the AC power line is interrupted for...
Open the catalog to page 10Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN Automatic OFF: The DC lines disconnect automatically if the AC line is interrupted for more than 3 seconds. Automatic ON: The DC lines reconnect automatically once the AC line is restored and stable for at least 5 seconds. Automatic OFF: DC lines disconnect and remain inactive after a manual remote command. Automatic ON: DC lines reconnect when the manual command is released, after verifying AC line status. Automatic OFF: DC lines disconnect if the cabinet temperature exceeds 100°C. Additional functions STATUS SIGNALING The electronic...
Open the catalog to page 11Smart Safety and Automatic Restart for PV Systems FB Series - Up to 6 inputs PLUG & PLAY Ready to use I We are available for additional custom configurations. Feel free to reach out to discuss your specific needs. Accessories - Control box Code String 1 String 2 String 3 String 4 String 5 String 6 Example of strings connections
Open the catalog to page 12Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN DISCONNECT SWITCH ELECTRONIC BOARD From 1 to 7 couple of inputs For Fire, Safety & Restart management Bremas Ersce S.p.A. recommends installing the SOLAR GUARDIAN away from direct sunlight.
Open the catalog to page 13SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems
Open the catalog to page 14SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems Warning! All EVO2 connectors must be correctly installed and securely sealed with an isolator to ensure compliance with the IP56 rating. Terminals recommended for the installation 32.0318P0001 (female) and 32.0319P0001 (male) are not included in the SOLAR GUARDIAN.
Open the catalog to page 15SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems
Open the catalog to page 16SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems Feedback FBI (FB2) GENERAL CATALOGUE I 17
Open the catalog to page 17Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN Electrical circuit Example of wiring connection for KA and KB Series SOLAR GUARDIAN SOLAR GUARDIAN SOLAR GUARDIAN SOLAR GUARDIAN 60 Vac/dc (max 1A) 60 Vac/dc (max 1A) 60 Vac/dc (max 1A) 60 Vac/dc (max 1A) 18 ❙ GENERAL CATALOGUE
Open the catalog to page 18Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN Features Dimensions
Open the catalog to page 19Smart Safety and Automatic Restart for PV Systems SOLAR GUARDIAN Wall fixing holes for brackets FB serie - up to 6 inputs
Open the catalog to page 20SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems KA and KB series - Up to 7 Inputs in [inch]
Open the catalog to page 21SOLAR GUARDIAN Smart Safety and Automatic Restart for PV Systems Horizontal fixing of PCB on DIN rail Vertical fixing of PCB on DIN rail
Open the catalog to page 22STRING BOXES
Open the catalog to page 23STRING BOXES DC STRING BOXES DIRECT CURRENT AC/DC STRING BOXES ALTERNATING AND DIRECT CURRENT AC STRING BOXES ALTERNATING CURRENT Discover more about our range of String Boxes MB Series. Visit our website or contact our technical team for further information.
Open the catalog to page 24The string boxes are made using specific components for the protection and wiring of a single string, two strings in parallel or two independent strings. Furthermore, it is possible to request customized configurations with wiring adapted to the type of PV system. Pre-wired string boxes with nominal voltage of 600 Vdc and 1000 Vdc are available, with overvoltage protection via type 2 Surge Protective Devices (SPD), overcurrent protection via fuse holders base (fuses included), and isolation via disconnect switches specific for DC-PV1 and DC-PV2 use categories (according to IEC EN 60947-3). The...
Open the catalog to page 25STRING BOXES DC STRING BOXESDirect Current I 1 string 600 Vdc • 1x DC input - 1x DC output • 1x Surge Protective Device, 600 Vdc, In=18 kA, Type 2 • 1x fuse holder base 1000 Vdc + 2x gPV fuse 20 A • Enclosure in insulating material, 8 DIN modules, • 1x Surge Protective Device, 1000 Vdc, In=18 kA, Type 2 • 1x fuse holder base 1000 Vdc + 2x gPV fuse 20 A • Enclosure in insulating material, 8 DIN modules,
Open the catalog to page 26STRING BOXES I 2 parallel strings 600 Vdc • 2x DC inputs - 1x DC output • 1x Surge Protective Device, 600 Vdc, In=18 kA, Type 2 • 2x fuse holder base 1000 Vdc + 4x gPV fuse 20 A • Enclosure in insulating material 12 DIN modules, • 2x Surge Protective Device, 600 Vdc, In=18 kA, Type 2 • 2x fuse holder base 1000 Vdc + 4x gPV fuse 20 A • Enclosure in insulating material 24 DIN modules, • 1x disconnect switch, 30 A at 1000 Vdc (DC-PV!) • 1x Surge Protective Device, 1000 Vdc, In=18 kA, Type 2 • 2x fuse holder base 1000 Vdc + 4x gPV fuse 20 A • Enclosure in insulating material 12 DIN modules, • 2x...
Open the catalog to page 275 Pages
42 Pages
152 Pages
12 Pages
86 Pages
104 Pages
19 Pages
448 Pages