Catalog excerpts
• Weather tight control package. • Two Pulse Width Modulated outputs • Protected against reverse polarity, short circuit, and over voltage conditions. • Current controlled output, maintains output current regardless of supply voltage and coil resistance variations. • Blast button is user adjustable anywhere from 0- 100% of Auger output. • Waterproof altitude pressure and vapor release vent allows enclosure to "breathe". • Independent ramp adjustments up and down, 0.1 -12 seconds. • Minimum and Maximum current adjustments for fine tuning each outputs span. • Wide voltage supply range 12-26 VDC, one control for 12 or 24VDC systems. The EC20100 was designed for material spreading equipment and applications requiring a dual output weatherproof control. The EC20100 is a compact, durable, and easy to operate control, built with high quality long life components that are designed for use in harsh environments. The EC20100 is a perfect compliment to the Brand EFC, LEFC, and SEFC flow controls. Other flow controls meeting the appropriate specifications may be used as well.
Open the catalog to page 1Electronic Controls CONTROL LAYOUT: 1. Deutsch Connector P/Ns: Receptacle Body: DT04-2P-E004 Secondary Wedge: W2P Terminals, Male: 0460-202-16141 Deutsch Connector P/Ns: Plug Body: DT06-4S-P012 Secondary Wedge: W4S-P012 Terminals, Female: 0462-201-16141 Deutsch Connector P/Ns: Plug Body: DT06-2S-P012 Secondary Wedge: W2S-P012 Terminals, Female: 0462-201-16141 Wire: GXL Cross-Link, 16-AWG Deutsch Connector P/Ns: Receptacle Body: DT04-4P-E004 Secondary Wedge: W4P Terminals, Male: 0460-202-16141 Wire: GXL Cross-Link, 16-AWG BLACK, EFC Ground BLUE, Positive Auger Output BLACK, Negative Supply...
Open the catalog to page 2Electronic Controls INTERNAL LAYOUT: Auger Power Indicator Spinner Power Indicator Auger Adjustments Spinners Adjustments Ramping Down Clockwise: Increases the Outputs Ramp off time. Ramping Down Clockwise: Increases the Outputs Ramp off time. Ramping Up Clockwise: Increases the Outputs Ramp on time. Ramping Up Clockwise: Increases the Outputs Ramp on time. Maximum Output Adjustment Clockwise: Increases Output Maximum Output Adjustment Clockwise: Increases Output Minimum Output Adjustment Clockwise: Increases Output Minimum Output Adjustment Clockwise: Increases Output Pass Output...
Open the catalog to page 3Electronic Controls TYPICAL SYSTEM CONFIGURATIONS: EC20100 & Brand SEFC Series Flow Control BLACK, Negative Supply EC20100 & Brand EFC Series Flow Controls BLACK BLUE BRAND HYDRAULICS BLACK, Negative Supply EC20100 & Unknown Series Flow Controls ORANGE BLACK BRAND HYDRAULICS S.N. BLACK BLUE BLACK, Negative Supply ORANGE BLACK 12V or 24V Proportional Flow Control 12V or 24V Proportional Flow Control NOTE: Brand Hydraulics recommends a 10 amp fuse be placed within 18 inches of this controls power source. The fuse and power source are customer supplied parts.
Open the catalog to page 4Electronic Controls DIMENSIONAL DATA: inches & [millimeters] Mounting Feet Can Be Rotated
Open the catalog to page 5Electronic Controls ADJUSTMENTS: Minimum output or zero setting Maximum output Ramping Down, or Fall Time Ramping Up, or Rise Time Clockwise rotation increases minimum output 0 - 1.1 Amps Clockwise rotation increases maximum output 0.05 - 2 Amps Maximum output will be 50 mA greater then the minimum output Clockwise rotation increases ramp time 0.1 - 12 Seconds, Clockwise rotation increases ramp time 0.1 - 12 Seconds Pass Output Clockwise rotation increases pass output 0 – 2 Amps Blast Output Clockwise rotation increases blast output 0 – 2 Amps ADJUSTMENT PROCEDURE: Adjustments are made by...
Open the catalog to page 6Electronic Controls MIN/MAX Adjustments Ramping Signal Input Control Output Control Output Slope = MAX trim Control Input Signal Output Current vs. Voltage Supply Fluctuation Output Regulation vs. Load Resistance (Set point 1 Amp, 26VDC Supply) Fall Time Rise Time Load Resistance in Ohms Output Current vs. Potentiometer Wiper Input NOTE: Unless stated otherwise the above readings were taken at 25C, with control connected to a 14.6V supply, and the output was set for 1 amp. Both Auger and Spinner outputs share these curve characteristics. It is the purchaser's responsibility to determine the...
Open the catalog to page 7All BRAND HYDRAULICS catalogs and technical brochures
-
V0200100000
3 Pages
-
V0100080000
3 Pages
-
V0100060000
3 Pages
-
V0100040000
3 Pages
-
V0100020000
3 Pages
-
BRAND Hydraulics - EC-12-02
4 Pages
-
FC 0-30 gpm (0-114 lpm)
4 Pages
-
BRAND Hydraulics - SHV
1 Pages
-
Series 84
1 Pages
-
BRAND Hydraulics - DS
7 Pages
-
RP01000003
5 Pages
-
RP01000002
5 Pages
-
84 series
1 Pages
-
LEFC
4 Pages
-
83 series
1 Pages
-
V100
3 Pages
-
RP01000001
5 Pages
-
POC76
1 Pages
-
SEFC
2 Pages
-
36EFC
4 Pages
-
Series38
10 Pages
-
Series 36
10 Pages
-
Series 34
10 Pages
-
MS6
2 Pages
-
Series 21
7 Pages
-
DS
7 Pages
-
BRAND Hydraulics - MS
2 Pages
-
SDCF
4 Pages
-
45 and 120 gpm (170-454 lpm)
3 Pages
-
30-45 gpm (114-170 lpm)
2 Pages
-
0-30 gpm
4 Pages
-
0-90 gpm (0-341 lpm)
2 Pages
-
Custom Electronic Packages
3 Pages
-
EC20300
10 Pages
-
EC0004A
7 Pages
-
EC20400
8 Pages
-
EC20200
8 Pages
-
EC-12-02
4 Pages
-
EC-12-01
4 Pages
-
DC
4 Pages
-
AO
4 Pages
-
B300
1 Pages
-
B series
2 Pages
-
FG
2 Pages
-
INTERFACE CARD
7 Pages
-
"TS" Catalog
5 Pages
-
PC - Pilot check valve
2 Pages