video corpo

CR06 Hybrid Recorder

CR06 Hybrid Recorder

CR06 Hybrid Recorder

Product catalog summary
Ordering Code
The CR06 hybrid recorder offers various configurations for communication and digital input/output (DI/DO). Communication options include standard RS-232C and RS-485. DI/DO options range from none to combinations of relay outputs and digital inputs. An out-of-paper sensor is optional.
Accessories
Available accessories include chart paper (Part number: HZCGA0105EL001) and a ribbon cassette (Part number: WPSR188A000001A).
Specifications
Input: The device supports 6 inputs with a sampling rate of 10s/6ch. It accepts direct voltage, direct current, thermocouples, and RTD inputs.
Performance: Accuracy is ±0.2%±1 digit max. Noise reduction is achieved with NMRR of 60dB min. and CMRR of 140dB min. Isolation resistance is 500VDC, 20MΩ min., and dielectric strength is 1.5kVAC for power input and 0.5kVAC for input terminals.
Alarm: Features 6 relay outputs with a capacity of 30VDC 3A max.
Communication: Standard interface is RS-232C, with RS-485 as an option.
Power Supply: Rated for 100-240VAC with a power consumption of 25VA max.
Structure: The device is panel-mounted, dust-proof, and water-proof (IP-65). Dimensions are 144(W) x 144(H) x 150(D) mm, and it weighs 1.5kg max.
Operation Condition: Suitable for temperatures 0-50°C and humidity 20-80%RH.
Recording / Printing Performance
Features raster-scan printing with a dotting interval of 10.0s/6ch max. The chart paper is 16m long with a dotting width of 100mm. Chart speed is user-selectable from 10-1500mm/hr. Printing colors include purple, red, green, blue, brown, and black.
See more

Catalog excerpts

CR06 Hybrid Recorder-2

Input sampling: 10s/6ch, max Type ofinput: Direct voltage: 10mV, 0-20mV, 0-50mV, ѱ 1V, 1-5VDirect ourrent: 4-20mAThermocouple: K, T, J, E,B,S,R,G,C,N,PR40-20, PLII, L, Au-FeRTD: Pt100, Pt50, JPt100 Performance Accuracy: 0.2% ѱ 1 digit max. for Digital indicator/printing Noise reduction : NMRR: 60dB min. CMRR: 140dB min. Isolation resistance: Each terminals/ground: 500VDC, 20M min. Dielectric strength: Power input terminal/ground: 1.5kVAC, 1 minute Input terminal/ground: 0.5kVAC, 1 minute Alarm Nos. of relay outputs: 6 outs (Form a contacts; Built-in option) Capacity: 30VDC 3A Max. Loaded > Interface:...