Overview
Bowman Heat Exchangers are integral components in emergency fire protection systems, providing reliable cooling solutions for engines and gearboxes under challenging conditions. Their products are trusted globally in both land and marine-based systems.

Product Range
Bowman offers a comprehensive range of heat exchangers, including jacket water header tank heat exchangers, shell and tube heat exchangers, oil coolers, charge air coolers, and fuel coolers. These products are supported by technical advice, replacement parts, and a network of stockists worldwide.

Standard Features
  • Precision Tubestack Design: Ensures efficient thermal transfer and low pressure drop.
  • Fully Floating Tubestack: Allows expansion and contraction, minimizing thermal stress.
  • Easy Maintenance: Removable tubestack and end covers simplify cleaning and maintenance.
  • Rapid Delivery: Most models are available for quick worldwide delivery.

Unique Design and Reliability
Bowman header tank heat exchangers feature a unique 'quiet zone' design with a de-aeration feature and pressurized filler cap, enhancing operational reliability by eliminating air pockets.

Oil Coolers
  • Wide Range: Over 40 models available, handling oil flows from 80 l/min to 1600 l/min.
  • High Temperature Capability: Can handle oil temperatures up to 200°C.
  • Fire Resistant Fluids: Compatible with alternative materials for fire-resistant fluids.

Charge Air Coolers
  • Improved Fuel Efficiency: Cools incoming air from the turbocharger, enhancing engine performance.
  • Wide Range: Suitable for engines up to 800kW.

Applications
  • South Africa: Used in mission-critical fire protection systems for aircraft and fuel stores.
  • Australia: Specified by leading fire pump manufacturers for building protection.
  • Scandinavia: High-performance pumps with Bowman oil coolers for marine and offshore installations.
  • Moses Mabhida Stadium: Integral to the stadium's emergency fire protection system.
See more

Catalog excerpts

Bowman Fire Pumps-1

BOWMAN HEAT EXCHANGERS Fire Pump Manufacturers Trust Bowman cooling solutions for the most high performance Emergency Fire Protection Systems You simply cannot afford to compromise on the quality of components in emergency fire protection systems. Quite literally, people’s lives could depend upon it! So when it comes to specifying heat exchangers to cool engines or gearboxes in these most challenging of emergency conditions, there’s one company you can trust – Bowman! Tried and extensively proven throughout the world, in both land and marine based active fire protection systems, you can have complete confidence in the quality and efficiency of Bowman heat exchangers for your emergency fire pump set. Standard features Bowman heat exchangers are extremely efficient in operation and provide a range of features that make them the preferred choice for Fire Pump Sets, including; Precision tubestack design Bowman shell and tube heat exchangers feature a precision engineered tubestack design, which provides extremely efficient thermal transfer and low pressure drop. Fully floating tubestack The ‘fully floating’ design allows expansion and contraction of the tubestack within the cast body of the heat exchanger, which minimises thermal stress. Bowman manufactures one of the most comprehensive ranges available, which includes jacket water header tank heat exchangers, shell and tube heat exchangers, oil coolers, charge air coolers and fuel coolers. All models are fully supported with technical advice, a comprehensive replacement parts service and a network of accredited stockists worldwide. Rapid delivery The tubestack and end covers are easily removable, making cleaning and routine maintenance procedures simple and straightforward. Most models are available ex-stock for rapid delivery worldwide. Heat Exchanger Technology by A World Leader in Heat Exchanger Technology

 Open the catalog to page 1
Bowman Fire Pumps-2

Bowman Heat Exchangers - at the heart of the most safety critical fire protection systems Active Building Protection Systems Durban International Airport Australia This leading Australian South Africa Bowman Header Tank units are at the heart of a ‘mission critical’ fire protection system dispensing foam for both aircraft and fuel stores in the event of an emergency. fire pump manufacturer exclusively specifies Bowman header tanks, charge air coolers and fuel coolers for all of its fire pumps, with literally hundreds of units now installed to protect buildings throughout Australia. Marine & Offshore...