Axial Piston Fixed Pump A2FO
36Pages

{{requestButtons}}

Catalog excerpts

Axial Piston Fixed Pump A2FO - 1

Axial Piston Fixed Pump A2FO Data sheet Series 6 Size 5 10 to 200 250 to 1000 Open circuit Nominal pressure/Maximum pressure 315/350 bar 400/450 bar 350/400 bar Ordering code for standard program 2 Features - Fixed pump with axial tapered piston rotary group of bent-axis design, for hydrostatic drives in an open circuit - For use in mobile and stationary applications - The flow is proportional to the drive speed and displacement - The drive shaft bearings are designed for the bearing service life requirements usually encountered in these areas - High power density - Small dimensions - High total efficiency - Economical design - One-piece tapered piston with piston rings for sealing General instructions

Open the catalog to page 1
Axial Piston Fixed Pump A2FO - 2

Ordering code for standard program Hydraulic fluid • = Available O = On request - = Not available | | = Preferred program 1) Conical shaft with threaded pin and woodruff key (DIN 6888). The torque must be transmitt

Open the catalog to page 2
Axial Piston Fixed Pump A2FO - 3

Ordering code for standard program Port plates for service lines25 10 to 16 23 to 250 355 to 1000 - = Not available | | = Preferred program 2) Fastening thread or threaded ports, metric

Open the catalog to page 3
Axial Piston Fixed Pump A2FO - 4

Technical data Hydraulic fluid Details regarding the choice of hydraulic fluid Before starting project planning, please refer to our data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids), RE 90222 (HFD hydraulic fluids) and RE 90223 (HFA, HFB, HFC hydraulic fluids) for detailed information regarding the choice of hydraulic fluid and application conditions. The correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature: in an open circuit, the reservoir temperature. The fixed pump A2FO is not...

Open the catalog to page 4
Axial Piston Fixed Pump A2FO - 5

Technical data Filtration of the hydraulic fluid Finer filtration improves the cleanliness level of the hydraulic fluid, which increases the service life of the axial piston unit. To ensure the functional reliability of the axial piston unit, a gravimetric analysis of the hydraulic fluid is necessary to determine the amount of solid contaminant and to determine the cleanliness level according to ISO 4406. A cleanliness level of at least 20/18/15 is to be maintained. At very high hydraulic fluid temperatures (90 °C to maximum 115 °C), a cleanliness level of at least 19/17/14 according to ISO...

Open the catalog to page 5
Axial Piston Fixed Pump A2FO - 6

Technical data Operating pressure range Pressure at service line port A or B Nominal pressure pnom The nominal pressure corresponds to the maximum design pressure. (operating with mineral oil) Size 5 Nominal pressure pnom___________________ 315 bar absolute Maximum pressure pmax_________________ 350 bar absolute Single operating period______________________________ 10 s Total operating period______________________________ 300 h Sizes 10 to 200 Nominal pressure pnom__________________ 400 bar absolute Maximum pressure pmax_________________ 450 bar absolute Single operating...

Open the catalog to page 6
Axial Piston Fixed Pump A2FO - 7

Technical data Table of values (theoretical values, without efficiency and tolerances; values rounded) 1) The values are valid: - at an absolute pressure pabs= 1 bar at suction port S - for the optimum viscosity range from vopt = 16 to 36 mm2/s - with hydraulic fluid based on mineral oils 2) Maximum speed (limiting speed) with increased inlet pressure pabs at suction port S, see adjacent diagram. 3) Torque without radial force, with radial force see page 8 4) Torque at Dp = 315 bar Note Operation above the maximum values or below the minimum values may result in a loss of function, a...

Open the catalog to page 7
Axial Piston Fixed Pump A2FO - 8

Technical dataPermissible radial and axial forces of the drive shafts (splined shaft and parallel keyed shaft) 1) With intermittent operation 2) Maximum permissible axial force during standstill or when the axial piston unit is operating in non-pressurized condition. 3) Conical shaft with threaded pin and woodruff key (DIN 6888) 4) Restricted technical data only for splined shaft 5) Please contact us. 6) When at a standstill or when axial piston unit operating in non-pressurized conditions. Higher forces are permissible when under pressure, please contact us. Note Influence of the direction...

Open the catalog to page 8
Axial Piston Fixed Pump A2FO - 9

Technical data Effect of radial force Fq on the service life of bearings By selecting a suitable direction of radial force Fq, the load on the bearings, caused by the internal rotary group forces can be reduced, thus optimizing the service life of the bearings. Recommended position of mating gear is dependent on direction of rotation. Examples: Determining the operating characteristics Vg • n • nv Flow qv = Vg = Displacement per revolution in cm3 Dp = Differential pressure in bar n = Speed in rpm nv = Volumetric efficiency nmh = Mechanical-hydraulic efficiency nt = Total efficiency (nt = nv...

Open the catalog to page 9
Axial Piston Fixed Pump A2FO - 11

Drive shafts B Parallel keyed shaft DIN 6885, A4x4x20 C Conical shaft with threaded pin and woodruff key, 3x5 (DIN 6888), (tapering 1:10) Ports Designation Center bore according to DIN 332 (thread according to DIN 13) Observe the general instructions on page 34 for the maximum tightening torques. Thread according to DIN 3852, maximum tightening torque: 30 Nm Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings. The spot face can be deeper than specified in the appropriate standard. O = Must be connected (plugged on...

Open the catalog to page 11
Axial Piston Fixed Pump A2FO - 12

Before finalizing your design, request a binding installation drawing. Dimensions in mm. Port plate 06 – Threaded port A/B at side and threaded port S at rear Illustration: cw direction of rotation (on version "ccw direction of rotation" the port plate is rotated through 180°) Flange similar to ISO 3019-2 View Y

Open the catalog to page 12
Axial Piston Fixed Pump A2FO - 13

Bosch Rexroth AG 13/34 Dimensions sizes 10, 12, 16 Before finalizing your design, request a binding installation drawing. Dimensions in mm. Drive shafts Sizes 10, 12, 16 A Splined shaft DIN 5480 W25x1.25x18x9g B Parallel keyed shaft DIN 6885, AS8x7x32 P Parallel keyed shaft DIN 6885, AS6x6x32 Ports Designation Center bore according to DIN 332 (thread according to DIN 13) Observe the general instructions on page 34 for the maximum tightening torques. Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings. O = Must be...