video corpo

Accumulator modules

Accumulator modules
1 / 16 PagesView full catalog

Accumulator modules

Product catalog summary
Features
The Bosch Rexroth AG Accumulator Modules, edition 2024-07, provide flexible installation options with configurations for 6, 8, and 10 accumulators in parallel, each with a 50-liter capacity, and single installations for 2 to 5 accumulators. They include options for manual or electric accumulator shut-off blocks and feature a glycerin-filled pressure gauge for maximum operating pressure. The modules are part of the component series 1X, with a maximum operating pressure of 330 bar.
Ordering Code
The ordering code details the modular accumulator unit type (ABMAXX-MAU), standard (N), component series (1X), number of accumulators (2 to 10), installation type (single or parallel), pressure relief type (manual or electro-magnetic), individual shut-off presence, country acceptance, and seal material (NBR or FKM).
Technical Data
Designed for vertical installation in low corrosion industrial environments, the modules support a maximum operating pressure of 330 bar and a hydraulic fluid temperature range of +10 to +65°C. The cleanliness class for hydraulic fluid is ISO 4406 class 20/18/15. The frame is steel with a CP3 surface coating for non-corrosive environments.
Installation Options
  • Single Installation: Available with 2 to 5 accumulators, featuring individual or overall shut-off options.
  • Parallel Installation: Available with 6, 8, or 10 accumulators, with similar shut-off options.
Both configurations offer manual and electric pressure relief options.
Dimensions and Weight
Dimensions are provided for both single and parallel installations, with weights ranging from 413 kg to 2073 kg depending on the configuration.
Selection Table
The selection table provides detailed options for accumulator size, pressure rate, number of accumulators, installation type, shut-off options, and discharge pressure type, along with corresponding material numbers.
Accessories
Accessories include mating connectors and cable sets for valves, with specific material numbers and data sheets provided.
Commissioning, Maintenance, and Operating Instructions
Users must adhere to machinery documentation, legal regulations, and national pressure vessel regulations. Operating instructions are provided according to the accumulator's data sheet, with standard country acceptance executed according to CE.
Specifications and Compliance
The document outlines specifications for accumulator modules, which are assemblies under Directive 2014/68/EU. These modules must comply with safety standards according to DIN EN ISO 4413. Modifications void the operating license and warranty.
Installation and Maintenance
Installation and maintenance should be performed by authorized personnel only. The end-user is responsible for compliance with existing regulations. Repairs must be conducted by the manufacturer or authorized dealers to maintain approval.
Safety and Operation
Accumulator modules should operate within permissible limits. Warning signs must be visible and in the appropriate language. Systems with hydraulic accumulators require additional visible warning signs.
Pressure Vessel Handling
Before disassembly, pressure must be discharged. Only nitrogen should be used for filling. The warning sign should be clearly visible on or near the device.
Additional Information
Data sheets are available for various hydraulic fluids and components, including pressure relief valves and directional seat valves. Further details on spare parts can be found on the Bosch Rexroth website.
Contact Information
Bosch Rexroth AG, Industrial Hydraulics, Zum Eisengießer 1, 97816 Lohr am Main, Germany. Phone: +49 (0) 93 52 / 40 30 20, Email: [email protected], Website: www.boschrexroth.com
See more

Catalog excerpts

Accumulator modules-1

Accumulator modules Modular accumulator unit N Component series 1X Maximum operating pressure 330 bar Accumulator volume 50 l per accumulator ▶ Parallel installation with 6, 8, and 10 accumulators, 50 l each ▶ Single installation with 2, 3, 4, and 5 accumulators, 50 l each ▶ With or without accumulator shut-off block for each accumulator ▶ Electrical or manual shut-off/pressure relief ▶ Glycerin-filled pressure gauge with red indication of the maximum admissible operating pressure on the dial Features1 Ordering code 2 Technical data 3 MAU accumulator modules, single installation 4 Dimensions: Accumulator with individual shut-off 5 Accumulator without individual shut-off 6 Dimensions: Accumulator without individual shut-off 7 MAU accumulator modules, parallel installation 8 Dimensions: Accumulator with individual shut-off 9 Accumulator without individual shut-off 10 Dimensions: Accumulator without individual shut-off 11 Selection table 12 Accessories (separate order) 13 Commissioning, maintenance and operating instructions 14 Further information 15 Notes16

 Open the catalog to page 1
Accumulator modules-2

Type ABMAXX-MAU | Accumulator modules Modular accumulator unit Component series 10 to 19 (10 to 19: unchanged installation and connection dimensions) Single installation Parallel installation Pressure relief – accumulator shut-off block 06 Manual and electro-magnetic (without manual override), normally open Set pressure at the pressure relief valve 330 bar Individual accumulator shut-off 08 Country acceptance for hydraulic accumulator 09 Acceptance according to Pressure Equipment Directive 2014/68/EU Bosch Rexroth AG, RE 51125, edition: 2024

 Open the catalog to page 2
Accumulator modules-3

Accumulator modules | Type ABMAXX-MAU 3/16 Technical data (Please consult us for applications outside these values!) General Installation position Line connections Vertical ▶ Pressure port Industrial building with low corrosion conditions, relative humidity < 60% Ambient temperature range Material Reservoir: steel; bladder: elastomer EN-GJS-400-15, surface zinc passivated (Fe//Ni5//Zn8//Cn//T0XXX) Weight (depending on configuration level) without oil Accumulator type Bladder-type accumulator according to data sheet 50171 For areas without a corrosive atmosphere, relative humidity < 60%. Class...

 Open the catalog to page 3
Accumulator modules-4

Type ABMAXX-MAU | Accumulator modules MAU accumulator modules, single installation ▶ 50 l pressure accumulator with accumulator shut-off block ▶ Single installation with 2, 3, 4, and 5 accumulators x 50 l ▶ Electrical and manual shut-off/pressure relief ▶ Unloading block, individually for each accumulator or as an overall shut-off for the entire accumulator module ▶ Two variants: with or without individual accumulator protection Accumulator with individual shut-off 210.1-.5 Accumulator shut-off block 217/218 Directional seat valve or blanking plug Bosch Rexroth AG, RE 51125, edition: 2024-07

 Open the catalog to page 4
Accumulator modules-5

Accumulator modules | Type ABMAXX-MAU 5/16 Dimensions: Accumulator with individual shut-off (dimensions in mm) Installation space for using the gas filling and test device Pressure relief

 Open the catalog to page 5
Accumulator modules-6

Type ABMAXX-MAU | Accumulator modules Accumulator without individual shut-off 211.1-.5 Accumulator 214.1-.4 Measuring coupling 215 Shut-off valve 216 Pressure relief valve 217/218 Directional seat valve or blanking plug Bosch Rexroth AG, RE 51125, edition: 2024-07 231 Check valve 227.1 Measuring hose 227.2 Measuring hose 240 Control cabinet

 Open the catalog to page 6
Accumulator modules-7

Accumulator modules | Type ABMAXX-MAU 7/16 Dimensions: Accumulator without individual shut-off (dimensions in mm) Installation space for using the gas filling and test device Pressure relief

 Open the catalog to page 7
Accumulator modules-8

Type ABMAXX-MAU | Accumulator modules MAU accumulator modules, parallel installation ▶ 50 l pressure accumulator with accumulator shut-off block ▶ Parallel installation with 6, 8, and 10 accumulators x 50 l ▶ Electrical and manual shut-off/pressure relief ▶ Two variants: with or without individual accumulator protection Accumulator with individual shut-off 240 201 Input block 202 Mounting plate 1x, right 217/218 Directional seat valve or blanking plug 219 Nozzle ⌀1,6 mm 203.1 Mounting plate 2x, right 203.2 Mounting plate 2x, right 204 Mounting plate 1x, left 205.1 Mounting plate 2x, left 230...

 Open the catalog to page 8
Accumulator modules-9

Accumulator modules | Type ABMAXX-MAU 9/16 Dimensions: Accumulator with individual shut-off (dimensions in mm) Installation space for using the filling and test device Pressure No. of relief accumulators

 Open the catalog to page 9
Accumulator modules-10

Type ABMAXX-MAU | Accumulator modules Accumulator without individual shut-off 218 Directional seat valve or blanking plug 202 Mounting plate 1x, right 203.1 Mounting plate 2x, right 203.2 Mounting plate 2x, right 204 Mounting plate 1x, left 205.1 Mounting plate 2x, left 205.2 Mounting plate 2x, left 211.1-.10 Accumulator 212.1-.4 Measuring coupling Bosch Rexroth AG, RE 51125, edition: 2024-07 230 Ball valve 231 Check valve 227.1 Measuring hose 227.2 Measuring hose 240 Control cabinet

 Open the catalog to page 10
Accumulator modules-11

Accumulator modules | Type ABMAXX-MAU 11/16 Dimensions: Accumulator without individual shut-off (dimensions in mm) Installation space for using the filling and test device Pressure relief

 Open the catalog to page 11
Accumulator modules-12

Type ABMAXX-MAU | Accumulator modules Selection table Accumulator Number of Accumulator pressure accumulators size in l rate in bar Individual Version accumulator Discharge pressure S (single) shut-off M (manual) or or S (with) or E (electro-magnetic) P (parallel) W (without) S Bosch Rexroth AG, RE 51125, edition: 2024-07 Material number Type / description

 Open the catalog to page 12
Accumulator modules-13

Accumulator modules | Type ABMAXX-MAU 13/16 Accessories (separate order) Measurement case ▶ For bladder-type accumulators (HAB) Mating connectors and cable sets Pos. 1) Designation 4 Mating connector; for valves with round connector, 6-pole + PE Short designation Material number Straight, metal Straight, plastic Angled, plastic RE 51125, edition: 2024-07, Bosch Rexroth

 Open the catalog to page 13
Accumulator modules-14

Type ABMAXX-MAU | Accumulator modules Commissioning, maintenance and operating instructions General Information ▶ Observe the documentation for the machinery. ▶ Also observe the documentation pertaining to the other components, assemblies and partly completed machinery, which form part of the complete machinery. ▶ Observe the generally applicable, legal or other compulsory regulations under European and national legislation as well as the relevant regulations on accident prevention and environmental protection for your country. ▶ Operating instructions according to the data sheet of the accumulator...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.