Small blower C65P1
3Pages

{{requestButtons}}

Catalog excerpts

Small blower C65P1 - 1

E-mail: sales@boreasa.com, URL : www.boreasa.com Single stage high pressure radial blower: Housing and Impeller materials: Medical grade thermoplastics Lead Wire: 300mm (AWG20 & 24) Weight: 180 gr. (6.35 oz.) Operational Temperature: -20 to 60 ºC / -4 to 140ºF Three Phase Brushless Motor w/ Hall Sensor Connector # Molex Microfit 43025-1000 Motor Internal Temperature Signal Note: This blower uses a brushless motor and needs a driver to operate Sample working point NOTES: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2° C) and sea level, and using a Boreasa D50/5/4Q-E2P driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

Open the catalog to page 1
Small blower C65P1 - 2

E-mail: sales@boreasa.com, URL : www.boreasa.com IN work. point @Nom. Volt. PN work. point @Nom. Volt. n work. point @Nom. Volt. V work. point @Nom. Volt. P work. point @Nom. Volt. Life10 (measured in Bi-level mode) hours Housing / Impeller Material Medical grade thermoplastic Ball Bearing Motor Internal Temperature Sensor *At given working points and cycle. Note: - Working point is an example close to 50% max flow - Values in this spec sheet are typical values, not guaranteed values For information, to receive a quotes or to place an order, e-mail us

Open the catalog to page 2
Small blower C65P1 - 3

E-mail: sales@boreasa.com, URL : www.boreasa.com Electrical Connections Wire Orange Red Green Blue White Brown Yellow Grey Violet Black Blower Limits and Warning Description HA Hall sensor A HB Hall sensor B VHall Vhall 3.5 ... 27 VCC W3 Motorwinding W IT1 Internal Temperature 1 HC Hall sensor C GND Ground W1 Motorwinding U W2 Motorwinding V IT2 Internal Temperature 2 No Hot-Swap allowed Max. allowed temperature on Heat Sink: Max. cont. speed: Max. cont. current allowed at 25º C: 85º C 60’000 rpm -12V: 12.8 A -18V: 8.2 A -24V: 6.4 A Blocking the impeller may result in damages or destruction...

Open the catalog to page 3