Gas blower C95L1-04
4Pages

{{requestButtons}}

Catalog excerpts

Gas blower C95L1-04 - 1

E-mail: sales@boreasa.com, URL : www.boreasa.com Radial Blower: C95L1 with internal driver 88.8 x 95.8 x 74.6 mm (3.50 x 3.77 x 2.94 in) Frame: Modified PPE + 20% fiberglass Impeller: Modified PPE + 20% fiberglass Lead Wire: 300mm (AWG22) Weight: 232 gr. (8.2 oz) Operational Temperature: -20 to 45 ºC / -4 to 113 ºF Three Phase Brushless Motor w/ Hall Sensor Optional Motor Internal Temperature Signal Note: This blower has an integrated driver Sample working point NOTES: - Performances measured with optional 25mm Outlet adapter. - Performances are dependent on the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level. It may be different than data measured in other conditions. - When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point. - Specifications are subject to change without notice.

Open the catalog to page 1
Gas blower C95L1-04 - 2

E-mail: sales@boreasa.com, URL : www.boreasa.com IN work. point @Nom. Volt. PN work. point @Nom. Volt. n work. point @Nom. Volt. V work. point @Nom. Volt. P work. point @Nom. Volt. Coming soon Depend on working point Housing / Impeller Material Internal Driver Ball Bearing Tacho 25mm Output Adapter Optional For information, to receive a quotes or to place an order, e-mail us at sales@boreasa.com Page 2/4

Open the catalog to page 2
Gas blower C95L1-04 - 3

E-mail: sales@boreasa.com, URL : www.boreasa.com Electrical Connections Wire Green Red Black Description VSP Speed Control Voltage VCC Power Supply + GND Ground Speed Calculation Blower speed [rpm] = 60 * FG FG = Generator Frequency Speed Control Voltage (VSP) Input Voltage Power Supply Requirements Voltage Ripple Voltage Current Blower Limits and Warning Manufacturing System Blower stopped ~ (VSP - 1)/1.8 * Blower Speed 100% Blower speed 100% Min. 0V Blower speed 100% Blower stopped No Hot-Swap allowed Do not exceed 4.0 V on VSP Max. allowed temperature on Heat Sink: 70º C Maximum cont....

Open the catalog to page 3
Gas blower C95L1-04 - 4

E-mail: sales@boreasa.com, URL : www.boreasa.com Typical Hookup 1. Using an external +4V power supply voltage and a potentiometer to control the blower speed. 2. Using a potentiometer to control the blower speed. 3. Using external analog control signal (0 - 4 V) to control the blower speed (note: Do not use DC power supply voltage).

Open the catalog to page 4

All Boreasa Technologies Co. catalogs and technical brochures

  1. C95M1-04

    4 Pages

  2. C65S1 24VDC

    3 Pages

  3. C65S1 12VDC

    3 Pages

  4. C60S1-01-L3

    3 Pages

  5. C60S1-01-L2

    3 Pages

  6. C60S1

    1 Pages

  7. F8025S-242-C

    1 Pages

  8. F4010S-124-L

    1 Pages