Gas blower C75M1-04
4Pages

{{requestButtons}}

Catalog excerpts

Gas blower C75M1-04 - 1

E-mail: sales@boreasa.com, URL : www.boreasa.com Miniature Radial Blower: C75M1 with internal driver 70.2 x 74.7 x 57.6 mm (2.76 x 2.94 x 2.27 in) Housing and Impeller materials: Medical grade thermoplastics Lead Wire: 300mm (AWG22) Weight: 235 gr. (8.3 oz) Operational Temperature: -20 to 50 ºC / -4 to 122 ºF Three Phase Brushless Motor w/ Hall Sensor Optional Motor Internal Temperature Signal Note: This blower has an integrated driver Sample working point Sample working point NOTES: - Performances are dependent on the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level. It may be different than data measured in other conditions. - When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

Open the catalog to page 1
Gas blower C75M1-04 - 2

E-mail: sales@boreasa.com, URL : www.boreasa.com IN work. point @Nom. Volt. PN work. point @Nom. Volt. n work. point @Nom. Volt. V work. point @Nom. Volt. P work. point @Nom. Volt. Depend on working point Housing / Impeller Material Medical grade thermoplastics Ball Bearing Motor Internal Temperature Sensor For informa on, to receive a quotes or to place an order, e-mail us at s

Open the catalog to page 2
Gas blower C75M1-04 - 3

E-mail: sales@boreasa.com, URL : www.boreasa.com Electrical Connections Wire Yellow Green Red Black White Description FG Generator Frequency VSP Speed Control Voltage VCC Power Supply + GND Ground IT Internal Temperature (optional) Speed Output Speed Calculation Blower speed [rpm] = 60 * FG FG = Generator Frequency Input Voltage Power Supply Requirements Voltage Ripple Voltage Current Blower Limits and Warning Blower stopped ~ (VSP - 1)/1.8 * Blower Speed 100% Blower speed 100% Min. 0V Blower speed 100% Blower stopped 8 - 30 V < 5% 3.5 A Read manual before use No Hot-Swap allowed Do not...

Open the catalog to page 3
Gas blower C75M1-04 - 4

E-mail: sales@boreasa.com, URL : www.boreasa.com Typical Hookup 1. Measuring the Generator Frequency to calculate the blower speed. 2. Using an external +3.3V power supply voltage and a potentiometer to control the blower speed. 3. Using a potentiometer to control the blower speed. 4. Using external analog control signal (0 - 3.3V) to control the blower speed (note: Do not use DC power supply voltage).

Open the catalog to page 4

All Boreasa Technologies Co. catalogs and technical brochures

  1. C95M1-04

    4 Pages

  2. C65S1 24VDC

    3 Pages

  3. C65S1 12VDC

    3 Pages

  4. C60S1-01-L3

    3 Pages

  5. C60S1-01-L2

    3 Pages

  6. C60S1

    1 Pages

  7. F8025S-242-C

    1 Pages

  8. F4010S-124-L

    1 Pages