C95M1-04
4Pages

{{requestButtons}}

Catalog excerpts

C95M1-04 - 1

E-mail: sales@boreasa.com, URL : www.boreasa.com Radial Blower: C95M1 with internal driver 88.7 x 95.8 x 56.7 mm (3.49 x 3.77 x 2.23 in) Frame: Modified PPE + 20% fiberglass Impeller: Modified PPE + 20% fiberglass Lead Wire: 300mm (AWG22) Weight: 255 gr. (9.0 oz) Operational Temperature: -20 to 45 ºC / -4 to 113 ºF Three Phase Brushless Motor w/ Hall Sensor Optional Motor Internal Temperature Signal Available in 12V on request Note: This blower has an integrated driver Sample working point NOTES: - Performances measured with optional 25mm outlet adapter. - Performances are dependent on the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level. It may be different than data measured in other conditions. - When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point. - Specifications are subject to change without notice.

Open the catalog to page 1
C95M1-04 - 2

E-mail: sales@boreasa.com, URL : www.boreasa.com IN work. point @Nom. Volt. PN work. point @Nom. Volt. n work. point @Nom. Volt. V work. point @Nom. Volt. P work. point @Nom. Volt. Depend on working point Leads Housing / Impeller Material Internal Driver Ball Bearing Motor Internal Temperature Sensor For informa on, to receive a quotes or to place an order, e-mail us at sales@borea

Open the catalog to page 2
C95M1-04 - 3

E-mail: sales@boreasa.com, URL : www.boreasa.com Electrical Connections Wire Yellow Green Red Black White Description FG Generator Frequency VSP Speed Control Voltage VCC Power Supply + GND Ground IT Internal Temperature (Optional) Speed Calculation Blower speed [rpm] = 60 * FG FG = Generator Frequency Speed Control Voltage (VSP) Input Voltage Power Supply Requirements Voltage Ripple Voltage Current Blower Limits and Warning Blower stopped ~ (VSP - 1)/1.8 * Blower Speed 100% Blower speed 100% Min. 0V Blower speed 100% Blower stopped 8 - 30 V < 5% 2.5 A No Hot-Swap allowed Do not exceed 3.3...

Open the catalog to page 3
C95M1-04 - 4

E-mail: sales@boreasa.com, URL : www.boreasa.com Typical Hookup 1. Measuring the Generator Frequency to calculate the blower speed. 2. Using an external +3.3V power supply voltage and a potentiometer to control the blower speed. 3. Using a potentiometer to control the blower speed. 4. Using external analog control signal (0 - 3.3V) to control the blower speed (note: Do not use DC power supply voltage).

Open the catalog to page 4

All Boreasa Technologies Co. catalogs and technical brochures

  1. C65S1 24VDC

    3 Pages

  2. C65S1 12VDC

    3 Pages

  3. C60S1

    1 Pages

  4. F8025S-242-C

    1 Pages

  5. F4010S-124-L

    1 Pages