C55H1-01

C55H1-01

C55H1-01

Product catalog summary
Specifications:
The C55H1-xxPS-01 is a miniature centrifugal blower with dimensions of 54.5 x 65.5 x 40.5 mm. It features a housing and impeller made from thermoplastics, weighs 100 grams, and operates within a temperature range of -20 to +50°C. It utilizes a three-phase brushless motor with a Hall sensor and requires a driver for operation. The blower is designed to meet medical device industry requirements but must be validated by customers for life support applications.

Technical Data:
The blower is available in two models: C55H1-12PS-01 and C55H1-24PS-01, with nominal voltages of 12 VDC and 24 VDC, respectively. Performance metrics such as zero flow, working point, and free flow are provided for each model, with specific values for pressure, current, speed, and power. The blower has a resistance of 0.73 Ω and 1.92 Ω, and an inductance of 0.100 mH and 0.370 mH for the 12V and 24V models, respectively. It has an acoustic emission level of less than 57 dB(A) and a lifespan of over 20,000 hours at 25°C.

Electrical Connections:
The blower's electrical connections include motor windings U, V, and W, Hall sensors A, B, and C, VHall, GND, and NTC, with specific wire colors and AWG sizes provided.

Blower Limits and Warnings:
The blower should not be hot-swapped, and the maximum continuous speed is 60,000 rpm. Blocking the impeller for more than 20 seconds can cause damage. A minimum airflow is required at voltages higher than nominal to prevent overheating.

Manufacturing and Standards:
The blowers are manufactured by an ISO9001-2015 certified manufacturer. The internal temperature of the motor is monitored by a 47 KΩ NTC resistor, indicating the motor's internal temperature.
See more

Catalog excerpts

C55H1-01-1

E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower C55H1-xxPS-01 54.5 x 65.5 x 40.5 mm (2.15 x 2.58 x 1.59 in) ∗ Housing / Impeller Materials: Thermoplastics ∗ Lead Wire: 285 mm (AWG22 & AWG26) ∗ Weight: 100 gr. (3.53 oz) ∗ Operational Temperature: -20 to +50°C / -4 to +122°F ∗ Three Phase Brushless Motor w/ Hall Sensor ∗ Connector(s): MOLEX 43025-1000 ∗ Standard Motor Internal Temperature Signal ∗ Note: This blower uses a brushless motor and needs a driver to operate Note: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level, and using a Boreasa D30/5/4Q-E2 driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

 Open the catalog to page 1
C55H1-01-2

E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH2O. N ote : - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power ±16%, speed ±5% and flow rate ±5%.

 Open the catalog to page 2
C55H1-01-3

E-mail: [email protected], URL: www.boreasa.com Electrical Connections Rear side view shown (Mating connector side) Description Motorwinding U Motorwinding V Motorwinding W Hall sensor A Hall sensor B Hall sensor C VHall 3 ... 24 VDC GND NTC Wire Brown Blower Limits and Warning Manufacturing System Motor Internal Temperature Signal (IT) * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower. * A minimum air flow is required at VCc higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. Blowers manufactured by ISO9001-2015...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.