Blower C68SS1

Blower C68SS1

Blower C68SS1

Product catalog summary
Specifications:
  • Material: Thermoplastics for housing and impeller.
  • Lead Wire: 235 mm (AWG22 & AWG28).
  • Weight: 190 grams (6.70 oz).
  • Operational Temperature: -20 to +50°C / -4 to +122°F.
  • Motor: Three Phase Brushless with Hall Sensor.
  • Connectors: TE CST-100 II 1375820-3 & TE Micro-Match 215083-6 or compatible.
  • Internal Temperature Signal: Standard.
Performance:
  • Performance varies with driver and test conditions; data obtained at 20°C and sea level using Boreasa D30/5/4Q-E2 driver.
  • Zero Flow at Nominal Voltage: 5,600 Pa, 600 mA, 41,100 rpm.
  • Working Point at Nominal Voltage: 3,740 Pa, 215 lpm, 1,400 mA, 37,000 rpm, 33.60 W.
  • Free Flow at Nominal Voltage: 400 lpm, 1,700 mA, 35,500 rpm.
Technical Data:
  • Nominal Voltage: 24 VDC, Voltage Range: 10 ~ 28 VDC.
  • Resistance (Phase-Phase): 1.20 Ω (±8%).
  • Inductance: 0.387 mH (±25%).
  • Inertia: 1,420 g·mm² / 0.0776 oz·in².
  • L10 at 25°C: > 30,000 hours.
  • Acoustic Emission Level: < 42.0 dB(A).
  • Ambient Storage Temperature: -20 to +80°C / -4 to +176°F.
  • Ambient Working Temperature: -20 to +50°C / -4 to +122°F (ice-free conditions).
  • Ambient Working Relative Humidity: 10 to 85% (non-condensing).
Warnings and Limits:
  • No Hot-Swap allowed.
  • Max. Temperature on NTC: 80°C.
  • Max. Continuous Speed: 52,000 rpm.
  • Blocking the impeller for more than 20 seconds may cause damage.
  • Minimum airflow required at VCC higher than nominal to prevent overheating.
Manufacturing and Connections:
  • Manufactured by ISO9001-2015 certified manufacturer.
  • Motor Internal Temperature Signal: Indicated by resistance of the 100 KΩ NTC.
  • Electrical Connections: Detailed pin descriptions for TE CST-100 II and TE Micro-Match connectors.
See more

Catalog excerpts

Blower C68SS1-1

E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower C68SS1-24PR-01-L368 x 78 x 51 mm (2.68 x 3.07 x 2.01 in) * Housing / Impeller Materials: Thermoplastics * Three Phase Brushless Motor w/ Hall Sensor * Connector(s): TE CST-100 II 1375820-3 & TE Micro-Match 215083-6 or Compatible * Standard Motor Internal Temperature Signal * Note: This blower uses a brushless motor and needs a driver to operate Note: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level, and using a Boreasa D30/5/4Q-E2 driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

 Open the catalog to page 1
Blower C68SS1-2

E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH2O. N ote : - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power ±16%, speed ±5% and flow rate ±5%.

 Open the catalog to page 2
Blower C68SS1-3

E-mail: [email protected], URL: www.boreasa.com Electrical Connections Blower Limits and Warning Description Motorwinding U Motorwinding V Motorwinding W Hall sensor A Hall sensor B Hall sensor C VHall (3.3 ... 24 VDC) GND NTC * Max. allowed temp. on NTC: 80°C * Max. cont. speed: 52,000 rpm * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower. * A minimum air flow is required at VCC higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. Manufacturing System Blowers manufactured by ISO9001-2015 certified manufacturer....

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.