Blower C55H1-01

Blower C55H1-01

Blower C55H1-01

Product catalog summary
Miniature Centrifugal Blower Specifications
  • Model: C55H1-xxPS-01
  • Dimensions: 54.5 x 65.5 x 40.5 mm (2.15 x 2.58 x 1.59 in)
  • Materials: Thermoplastics for housing and impeller
  • Weight: 100 grams (3.53 oz)
  • Operational Temperature: -20 to +50°C (-4 to +122°F)
  • Motor: Three-phase brushless with Hall sensor
  • Connector: MOLEX 43025-1000
  • Note: Requires a driver for operation
Performance and Testing Conditions
  • Performance depends on the driver and test conditions
  • Data obtained at 20°C (±2°C) and sea level using Boreasa D30/5/4Q-E2 driver
  • Performance may vary when used as a vacuum or in different conditions
  • Designed for medical device industry requirements
Technical Data
  • Nominal Voltage: 12 VDC and 24 VDC models
  • Voltage Range: 9-14 VDC (12V model), 10-28 VDC (24V model)
  • Zero Flow Pressure: 4,820 Pa (12V), 5,500 Pa (24V)
  • Working Point Pressure: 3,373 Pa (12V), 4,400 Pa (24V)
  • Free Flow Rate: 472 lpm (12V), 510 lpm (24V)
  • Acoustic Emission Level: < 57.0 dB(A)
  • Ambient Storage Temperature: -20 to +80°C (-4 to +176°F)
  • Ambient Working Temperature: -20 to +50°C (-4 to +122°F)
  • Relative Humidity: 10 to 85% (non-condensing)
Electrical Connections
  • Motor windings and Hall sensors have specific pin assignments and wire colors
  • Max. continuous speed: 60,000 rpm
  • Blocking impeller for more than 20 seconds may cause damage
  • Minimum airflow required at higher voltages to prevent overheating
Manufacturing and Safety
  • Manufactured by ISO9001-2015 certified manufacturer
  • Internal temperature monitored by a 47 KΩ NTC thermistor
  • No hot-swapping allowed
  • Max. temperature on NTC: 80°C
See more

Catalog excerpts

Blower C55H1-01-1

E-mail: [email protected], URL: www.boreasa.com Miniature Centrifugal Blower C55H1-xxPS-01 54.5 x 65.5 x 40.5 mm (2.15 x 2.58 x 1.59 in) ∗ Housing / Impeller Materials: Thermoplastics ∗ Lead Wire: 285 mm (AWG22 & AWG26) ∗ Weight: 100 gr. (3.53 oz) ∗ Operational Temperature: -20 to +50°C / -4 to +122°F ∗ Three Phase Brushless Motor w/ Hall Sensor ∗ Connector(s): MOLEX 43025-1000 ∗ Standard Motor Internal Temperature Signal ∗ Note: This blower uses a brushless motor and needs a driver to operate Note: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level, and using a Boreasa D30/5/4Q-E2 driver. It may be different than data measured in other conditions or with other drivers. - When used as a vacuum, the blower performance might be less than shown herein, depending on the operating point. - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

 Open the catalog to page 1
Blower C55H1-01-2

E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 10 cmH2O. N ote : - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power ±16%, speed ±5% and flow rate ±5%.

 Open the catalog to page 2
Blower C55H1-01-3

E-mail: [email protected], URL: www.boreasa.com Electrical Connections Rear side view shown (Mating connector side) Description Motorwinding U Motorwinding V Motorwinding W Hall sensor A Hall sensor B Hall sensor C VHall 3 ... 24 VDC GND NTC Wire Brown Blower Limits and Warning Manufacturing System Motor Internal Temperature Signal (IT) * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower. * A minimum air flow is required at VCc higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. Blowers manufactured by ISO9001-2015...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.