Blower C105H2
1 /3Pages

Blower C105H2

Blower C105H2
1 /3Pages

Catalog excerpts

Blower C105H2-1

E-mail: [email protected], URL: www.boreasa.com * Housing / Impeller Materials: Metal * Three Phase Brushless Motor w/o Hall Sensor * Standard Motor Internal Temperature Signal * Note: This blower has an integrated driver NOTES: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°C) and sea level. It may be different than data measured in other conditions. - When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point - Specifications are subject to change without notice. - Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by customers, in their actual application conditions, in a statistically meaningful quantity.

 Open the catalog to page 1
Blower C105H2-2

4^ Boreasa E-mail: [email protected], URL: www.boreasa.com #1 At given working points and cycle. #2 Measured at distance of 1 meter from inlet, with open inlet, outlet connected to breathing tube and 4 mm orifice in sound chamber at 1 kPa. Note: - Working point is an example close to 50% of max. flow. - The phase inductance and impedance are measured by LCR at 1 kHz, including the connector. - Tolerances based on specified speed data according to ISO 13348, grade 4: pressure ±10%, power +16%, speed ±5% and flow rate ±5%.

 Open the catalog to page 2
Blower C105H2-3

E-mail: [email protected], URL: www.boreasa.com Electrical Connections Pin Description Set speed input Tachometer output NTC Speed Calculation Blower speed [rpm] = 20 * FG Power Supply Requirements Voltage Ripple Voltage Current Blower Limits and Warning * Read manual before use * Blocking the impeller more than 20 seconds may result in damages or destruction of the blower, unless current is limited to values listed above. * A minimum air flow is required at VCc higher than Nominal Voltage to avoid the air in the blower to overheat by compressing and mixing. * Over Current Protection. When the...

 Open the catalog to page 3