PULL UP I2C CONNECTION IS.ACI2C-4.7K

PULL UP I2C CONNECTION IS.ACI2C-4.7K

Product catalog summary
Specifications:
PT 4 Feed-Through and Multi-Conductor Terminal Blocks offer a compact design with 50% less insertion force, facilitating wiring in tight spaces. They support tool-free wiring for conductors with ferrules or solid conductors. Stranded conductors with ferrules can be inserted directly using PIT 2.5 (from 0.34 mm²) and PIT 4 (from 0.5 mm²). The actuation lever opens the terminal point, preventing direct contact with live parts. A double bridge shaft allows for individual potential distribution and supply.
Procedures:
Tool-free wiring is enabled for ease of use, and the actuation lever ensures safety by preventing direct contact with live parts.
Norms and Standards:
CE marking indicates compliance with European Union regulations. Symbols are used to identify terminals suitable for direct or alternating current, control pulses, earth terminals, and switches for signal lamps. Hazard symbols indicate potentially dangerous situations and dangerous voltages.
Recommendations:
For technical support, users can visit the blog, forum, or ticketing system at www.industrialshields.com or contact support via email at [email protected].
Technical Support:
Contact options include visiting the blog, forum, or using the ticketing system for assistance.
See more

Catalog excerpts

PULL UP I2C CONNECTION IS.ACI2C-4.7K-1

INDUSTRIAL PULL UP I2C CONNECTION IS.ACI2C-4.7K PT 4 Feed-Through and Multi-Conductor Terminal Blocks 50% less insertion force Compact design and front connection facilitate wiring in the smallest of spaces. Tool-free wiring of conductors with ferrules or solid conductors. Stranded conductors with ferrules can be inserted directly with PIT 2,5 (from 0.34 mm2) and PIT 4 (from 0.5 mm2). Actuation lever opens the terminal point, so there is no direct contact with live parts. Double bridge shaft enables individual potential distribution and supply. Symbology Indicates that the equipment is suitable for direct current only; to identify relevant terminals Indicates that the equipment is suitable for alternating current only; to identify relevant terminals To identify the control by which a pulse is started. To identify an earth (ground) terminal in cases where neither the symbol 5018 nor 5019 is explicily required. To identify the switch by means of which the signal lamp(s) is (are) switched on or off. CE marking indicates that a product complies with applicable European Union regulations Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury To indicate hazards arising from dangerous voltages Technical Support You can contact with us using the best channel for you: @ [email protected] www.industrialshields.com Visit our Blog, Forum orTicketing system 34 644 927 900 Use our chat service Check the user guides Visit our Channel