Product catalog summary
General Overview
This document provides comprehensive technical specifications and guidelines for the V series motovariators and associated components, including motovariators, accessories, motorized geared variators, and electric motors.
Specifications and Units of Measure
Key parameters include output torque, rated power, thermal capacity, gear ratio, speed, service factor, radial and thrust loads, and lubrication requirements.
Technical Specifications
  • Output Torque: Details on nominal, required, and calculated torque with formulas for specific applications.
  • Rated Power and Thermal Capacity: Power capabilities and thermal limits are outlined.
  • Gear Ratio and Speed: Information to assist in selecting the right motovariator.
Installation and Maintenance
Guidelines for installation, maintenance, and storage to ensure optimal performance and longevity, including lubrication instructions and service factor considerations.
Standards and Compliance
References to compliance with NEMA standards for certain models, ensuring compatibility and reliability in industrial applications.
Additional Features
Information on accessories, paint specifications, and supply conditions for a comprehensive understanding of product offerings and customization options.
Motor Specifications
Details on electric motors, including design versions, ventilation, insulation class, and protection degrees, covering various motor types.
Revisions and Updates
Note on revisions, directing users to the company's website for the latest updates and catalog versions.
Output Torque
  • Nominal Torque: Torque transmitted at the output shaft under continuous load.
  • Required Torque: Torque demanded by the application.
  • Calculated Torque: Used for gearbox selection, considering required torque and service factor.
Thermal Capacity
  • Thermal Power: Gearbox's thermal limit and power transmission capacity under continuous duty.
Rated Power
  • Rated Power: Applicable input power referred to speed n1.
Gear Ratio
  • Gear Ratio: Calculated from input speed n1 and output speed n2.
Speed
  • Input Speed: Related to the type of drive unit selected.
  • Output Speed: Calculated from input speed n1 and transmission ratio i.
Service Factor
  • Service Factor: Considers load variations and shocks the gearbox may undergo.
Radial Loads
  • Radial Loads: Calculated using the formula Rc2, considering factors like torque, diameter, and type of transmission.
Thrust Loads
Maximum permissible thrust loads are calculated similarly to radial loads.
Gearbox Lubrication
Lubrication achieved through oil immersion and oil-splash patterns, with specific recommendations for ambient temperature operations.
Specifications and Usage
Mechanical variators operate up to the limit of permitted torque without slippage, with a maximum of 8-10 starts per minute.
Selection of Motovariators
Determine the service factor based on load type, number of starts per hour, and hours of operation.
Verification Procedures
Verify the thermal capacity of the gear unit and check radial and axial loads against catalog values.
Technical Data and Standards
References CEI 2-3/IEC 34-1 standards for motor duty types and provides tables for efficiency values.
Installation Instructions
Ensure secure fixing to prevent vibrations and protect machined surfaces before painting.
Load Considerations
Radial and thrust loads on output shafts must be within catalog values.
Electric Motors
Ensure flange and shaft machining tolerances are precise.
Storage Guidelines
Avoid outdoor storage or areas with high humidity.
Supply Conditions
Units are supplied ready for installation, tested to manufacturer specifications.
Paint Specifications
Paint specifications can be requested from suppliers.
Design Characteristics
Motovariators feature high-resistance cast-iron cases, compactness, reliability, and maintenance-free operation.
Versions
Different configurations include differential and solid output shaft, bolt-on feet, and mounting flange options.
Designation
Includes variator size, type, differential, output shaft diameter, input configuration, version, mounting position, and options.
Specifications and Components
Various components such as grub screws, chains, and electronic cards are listed with translations.
Wiring Diagrams
Diagrams for proper wiring of the TELECOM electric control.
Lubrication of Variators
Variators require splash lubrication, with specific oil recommendations.
Oil Types and Recommendations
Specific oil types are recommended for different variator models.
Mounting Positions and Control
Table outlines possible mounting positions for variators.
Technical Data
Technical data tables provide detailed specifications for various models.
Specifications
Bonfiglioli gear units require specific lubrication and temperature conditions for optimal operation.
Procedures
Ensure gear unit is filled with the correct amount of oil before starting.
Standards and Recommendations
Use long-life polyglycol-based lubricant and genuine motors with oil seals.
Lubricant Quantities
Detailed table of oil quantities required for different frame sizes and mounting positions.
Specifications and Versions
Various versions of variators with specific configurations and mounting positions.
Procedures
Replace blind plug with vented plug before starting variators.
Lubrication and Maintenance
Use synthetic "long life" lubricants for variators.
Operating Conditions
Gear units can operate in ambient temperatures ranging from -20°C to +40°C.
Mounting Positions
Gearboxes are primarily designed for base mounting position B3.
Oil Quantities and Filling Instructions
Indicative oil quantities for various models and mounting positions.
Lubrication Specifications
Permanent lubrication with synthetic oil allows installation in all mounting positions.
Torque Limiter and Dimensions
Table detailing dimensions and specifications for various models.
Symbols and Units of Measure
Comprehensive list of symbols and units covering power factor, efficiency, torque factors, and speed measurements.
Production and Standards
Low-voltage three-phase asynchronous motors comply with CEI/EN and IEC standards.
Compliance and Directives
BN series motors meet requirements of Directives 2006/95/EC and 2004/108/EC.
Tolerances
Allowed tolerances for guaranteed parameters according to CEI EN 60034-1 standards.
Geometric Tolerances
Dimensions and tolerances for shaft ends, keys, and flanges comply with standards.
Noise Level
Noise levels measured according to ISO 1680 and comply with CEI EN 60034-9 standards.
Direction of Rotation
Motors can operate in both clockwise and counterclockwise directions.
Bearings
Motors use axially pre-loaded radial ball bearings, lubricated for life.
Standard Operation
Motors are designed for specific voltage and frequency ranges.
60 Hz Operation
BN motors can operate on 60 Hz power mains.
Specifications
Motors available in basic and derived design versions.
Procedures
Design extends torque-control operating range for motors controlled by inverters.
Standards
Motors comply with CEI EN 60034-6 standards.
Recommendations
Ensure proper installation distance for ventilation.
Key Data from Tables
Power Supply Chart, Dimension Variations, and Protection Classes.
Options and Variants
Motors can be equipped with various options such as thermal protective devices and feedback devices.
Specifications
Specifications for incremental encoders with different power supply voltages and output types.
Procedures and Recommendations
Guidelines for operation and installation of motors.
Standards and Norms
Compliance with CEI EN 60034-14 for vibration class.
Additional Features
High braking torques with adjustable settings and manual release lever options.
Specifications
Features of spring-applied brakes type FD and FA.
Brake Release Systems
Optional manual release levers for maintenance purposes.
Separate Brake Supply
Brake coil powered independently from the motor.
Maximum Starts Per Hour
Maximum number of starts per hour under no-load conditions.
Soft-Start/Stop
Optional flywheel for applications requiring soft starting or stopping.
Capacitive Filter
Optional capacitive filter for DC brake motors type BN_FD.
Specifications
DC brake motors with toroidal-coil electromagnetic brake.
Procedures
Optional manual release lever for brake motors.
Standards and Norms
Compliance with electromagnetic compatibility standard EN 50081-1.
Recommendations
Rectifiers NBR or SBR recommended for quick brake release.
Technical Specifications
Detailed specifications for FD brakes.
Key Data from Tables
Standard and optional rectifier types and available voltages for brake power supply.
Brake Connections and Specifications
Standard single-speed motors with rectifier connected to motor terminal board.
Brake Torque and Performance
Specifications for brake torque and performance metrics.
Brake Motor Types and Features
AC brake motors with electromagnetic brakes powered by three-phase AC supply.
Power Supply Configurations
Brake coil powered directly from motor terminal box for single-pole motors.
Connection Diagrams
Typical connection diagrams for power supply and brake systems.
See more

Catalog excerpts

V series Motovariator-1

GOO Bonfiglioli power, control and green solutions

 Open the catalog to page 1
V series Motovariator-3

INFORMAZIONI GENERALI GENERAL INFORMATION ALLGEMEINE INFORMATIONEN INFORMATIONS GENERALES Paragrafo Heading Abschnitt Descrizione Description 1 Simbologia e unita di misura 2 Coppia in uscita 17 Specifiche della vernice Symbols and units of measure Output torque Rated power Thermal capacity Gear ratio Speed Service factor Radial loads Thrust loads Gearbox lubrication Maintenance Selection VerifiacHoo Installation Storare Supply conditions Paint specifications Verwendete Symbole und Einheiten Abtriebsmoment Nenn-Leistung Warmeleistung Obersetzung Drehzahl Betriebsfaktor Radialkrafte Axialkrafte Schmierung...

 Open the catalog to page 3
V series Motovariator-4

1 valore riferito all’albero veloce 1 value applies to i/p shaft 1 Werte beziehen sich auf die 1 valeurs pour i'arbre rapide 2 valore riferito all’albero lento 2 value applies to o/p shaft Antriebswelle 2 valeurs pour I'arbre lent 2 Werte beziehen sich auf die Abtriebswelle

 Open the catalog to page 4
V series Motovariator-5

Questo simbolo riporta i riferimenti angolari per l'indicazione della direzione del carico radiale (l'albero è visto di fronte). This symbol indicates the radial load direction angle references. (shaft front-view). Dieses Symbol gibt die Winkelbezugswerte für die Angabe der Richtung der Radialkräfte an (Stirnansicht der Welle). Ce symbole présente les références angulaires pour l'indication de la direction de la charge radiale (l'arbre est vu de face). Le colonne contrassegnate da questo simbolo indicano i numeri di pagina dove sono riportate le dimensioni. Columns marked with this symbol indicate...

 Open the catalog to page 5
V series Motovariator-6

INFORMAZIONI GENERALI GENERAL INFORMATION ALLGEMEINE INFORMATIONEN INFORMATIONS GENERALES I paragrafi che seguono riportano una serie di informazioni sugli elementi indispensabili per la scelta e il corretto utilizzo dei motovariariduttori. Indicazioni specifiche relative alle varie tipologie di riduttori potranno essere ricercate nei capitoli di pertinenza. The following headings contain information on essential elements for selection and correct use of motovariator-gearboxes. For specific data on the gearbox range, see the relevant chapters. Die folgenden Abschnitte enthalten eine Reihe von...

 Open the catalog to page 6
V series Motovariator-7

(B1) Fattore di temperatura / Temperature factor / Temperaturfaktor / Facteur de temperature 3.0 - POTENZA NOMINALE Pn-i [kW] 3.0 - PUISSANCE NOMINAL Pnt [kW] Nelle tabelle di selezione dei motovariariduttori e la potenza applicata in entrata riferita alla velocita n1 e considerando un fattore di servizio fs=1. In the motovariator-gearboxes selection charts, this is the applicable input power referred to speed n1 and considering a service factor fs=1. In den Tabellen fur die Wahl der Verstellgetriebemotors ist die an der Antriebswelle uber-tragbare Leistung auf die Dreh-zahl n-i bezogen und es...

 Open the catalog to page 7
V series Motovariator-8

II rapporto di intermittenza (I)% e dato dal rapporto fra il tempo di funzionamento a carico tf e il tempo totale espresso in per-centuale: The cyclic duration factor (I)% is obtained from the ratio operating time under load tf with respect to total time expressed as a percentage: Die relative Einschaltdauer (l)% ist das Verhaltnis aus der Be-triebsdauer unter Last tf und der Gesamtbetriebszeit, ausge-druckt in Prozent: Le rapport d'intermittence (l)% est donne par le rapport entre la duree de fonctionnement en charge tf et le temps total exprime en pourcentage: 5.0 - RAPPORTO DI RIDUZIONE E...

 Open the catalog to page 8
V series Motovariator-9

È il fattore che tiene in considerazione, con sufficiente approssimazione, la variabilità del carico e gli eventuali urti a cui è sottoposto il riduttore per un determinato tipo di servizio. Nel grafico della tabella (B4), dall’intersezione della linea corrispondente al numero di inserzioni/ora (avviamenti e arresti) con una delle curve (K1, K2, K3), che identificano la natura del carico in funzione del fattore di accelerazione delle masse K, si potrà leggere nel grafico il valore del fattore di servizio fs riferito al numero di ore di fuzionamento giornaliere. Eventuali valori intermedi potranno...

 Open the catalog to page 9
V series Motovariator-10

Gli alberi di entrata e uscita dei Gearbox input and output riduttori possono essere sog- shafts can be subjected to ra-getti a carichi radiali (determi- dial loads (determined by the nati dal tipo di trasmissione rea- type of transmission used) the lizzata) la cui entita puo essere extent of which can be calcu-calcolata con la formula: lated with the following formula: 8.0 - RADIALKRAFTE Die Antriebs- und Abtriebswellen der Getriebe konnen Radialkraf-ten ausgesetzt sein (die von der Ubertragungsart abhangig sind), deren AusmaR mit folgender Formel bestimmt werden kann: 8.0 - CHARGES RADIALES...

 Open the catalog to page 10
V series Motovariator-11

8.1 - Carichi radiali sull’albero lento Rn2 8.1 - Radial loads on output shaft Rn2 Rated values of radial loads referred to the mid-point of the output shaft extension are shown in the motovariator-gear-box unit selection charts. They are calculated based on transmitted torque M2 and assuming the most unfavourable conditions in terms of both load angle and direction of rotation of the shaft. If permitted values are below actual values, please consult our technical service reporting exact load orientation and shaft rotation direction. 8.1 - Radialkrafte auf die Abtriebswelle Rn2 Die Nennwerte...

 Open the catalog to page 11
V series Motovariator-12

Un sistema misto bagno d’olio-sbattimento garantisce di regola la lubrificazione dei riduttori. Per alcune posizioni di montaggio, generalmente caratterizzate da uno dei due assi verticali, opportune precauzioni vengono adottate al fine di garantire una adeguata lubrificazione anche agli organi più sfavoriti. Lubrication of gear units is usually provided through a combination of oil immersion and oil-splash patterns. For some mounting positions, typically those featuring a vertical shaft, provisions are made to guarantee lubrication of even the least favourably located drive components. Normalerweise...

 Open the catalog to page 12
V series Motovariator-14

Per selezionare correttamente un motovariatore, è necessario disporre di alcuni dati che abbiamo sintetizzato nella tabella (B10). In particolare, essa potrà essere compilata ed inviata in copia al ns. Servizio Tecnico che provvederà alla ricerca della motorizzazione più idonea alla applicazione indicata. Some fundamental data are necessary to assist the correct selection of a motovariator. The table below (B10) briefly sums up this informaiton. To simplify matters, fill in the table and send a copy to our Technical Service which will select the most suitable drive unit for your application requirements....

 Open the catalog to page 14

All Bonfiglioli catalogs and technical brochures

  1. HDP

    88  Pages

  2. Wind Solutions

    24  Pages

  3. 610X Series

    2  Pages

  4. 600Y3 Series

    2  Pages

  5. 600W series

    2  Pages

  6. Active Cube 7

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.