Overview: The document addresses safety directives related to explosion risks in machinery, focusing on the ATEX Directive 2014/34/EU, which takes precedence over the Machinery Directive 2006/42/EC for explosive atmospheres. It covers equipment classification and protection levels for such environments.
Key Directives:
  • ATEX Directive 2014/34/EU: Effective from April 20, 2016, this directive applies EU-wide, covering mechanical, hydraulic, pneumatic, and electrical equipment in explosive atmospheres.
  • Machinery Directive 2006/42/EC: Provides general explosion safety requirements, but ATEX Directive is prioritized for specific explosion risks.
Equipment Classification:
  • Zones: Equipment is classified for zones 1, 21, 2, and 22, based on the frequency of explosive atmosphere formation.
  • Protection Levels: Equipment must meet manufacturer-specified protection levels: very high, high, or normal.
  • Groups: Group I is for mining, Group II for other explosive areas. BONFIGLIOLI RIDUTTORI products are not suitable for Group I and Group II, category 1 applications.
Product Compliance: BONFIGLIOLI RIDUTTORI gear units are designed for potentially explosive atmospheres, limited to categories 2 and 3, complying with ATEX Directive safety requirements.
Verification Procedures:
  • Maximum Torque: Ensure torque does not exceed 200% of rated torque Mn2. For three-phase motors, manage switching torque carefully.
  • Radial Loads: Verify radial forces on shafts are within limits; consider larger units if exceeded.
  • Thrust Loads: Ensure thrust loads are within 20% of overhung load capacity; consult technical service for high loads.
  • Starts per Hour: Ensure starting capability is within limits for high switch duties.
Installation, Use, and Maintenance:
  • Follow the manual for installation, use, and maintenance, available at www.bonfiglioli.com.
  • Maintain ambient temperature between -20°C and +40°C.
  • Ensure motor speed does not exceed 1500 min-1; use suitable motors for inverter applications.
  • Secure gearbox to prevent vibrations; install protective elements if shocks or overloads are expected.
  • Protect nameplate and seal rings during painting.
  • Machine parts to ISO H7 tolerance; use protective paste for key couplings.
Specifications and Procedures:
  • Motor speed with reducer must not exceed 1500 min-1; ensure frequency converter settings prevent overloads.
  • Ensure stable reducer mounting to avoid vibrations; install couplers or limiters for shocks or overloads.
  • Protect identification plate and sealing rings before painting.
  • Components on slow shaft should meet ISO H7 tolerance to avoid damage.
  • Clean and treat contact surfaces with protective products before assembly.
  • For outdoor installations, protect gear unit and motor from weather with guards or casings.
Conditions of Supply:
  • Gear units are supplied configured for specified mounting, tested to specifications, with unpainted surfaces, and equipped with mounting hardware.
  • Shafts are protected during transport and supplied with a lifting lug where applicable.
Paint Specifications:
  • Paint specifications for gearboxes are available from suppliers or dealers.
Construction of ATEX-Specified Equipment:
  • Equipped with service plugs, vent caps, and factory-charged with synthetic lubricant.
  • Standard fluoro elastomer seal rings, no plastic components, operable at specified temperature limits.
  • Temperature indicators supplied with each unit.
Versions and Options:
  • Various gearbox options for zones 21 and 22 (categories 2D and 3D) with surface temperatures below 160°C or 130°C, and zones 1 and 2 (categories 2G and 3G) with temperature classes T3 or T4.
Lubrication:
  • Gear units use oil-bath and splash lubrication; ATEX versions are factory-filled with "long-life" lubricant SHELL OMALA S4 WE 320.
  • Check oil level or fill gearbox as instructed in the manual available on the Bonfiglioli website.
Specifications and Calculations: The document provides calculation procedures for input/output shafts and axial loads, with specific formulas and conditions for functionality. Axial load calculations are based on radial loading values, with guidelines for permissible loads and consultation with technical services if exceeded.
Technical Data and Installation Guidelines: Includes technical data for gearboxes, installation conditions, and guidelines for maximum motor power. Gearbox rating charts assist in selecting appropriate models based on application requirements.
Recommendations: For excessive axial forces, contact Bonfiglioli Riduttori for analysis. Adhere to specified conditions and consult technical services when necessary.
See more

Catalog excerpts

Serie F - Shaft mounted gear units - Atex-1

F series Riduttori pendolari Dal 1956 Bonfiglioli progetta e realizza soluzioni innovative ed affidabili per il controllo e la trasmissione di potenza nell’industria e nelle macchine operatrici semoventi e per le energie rinnovabili. Shaft mounted gear units Aufsteckgetrieben Réducteurs pendulaires Bonfiglioli has been designing and developing innovative and reliable power transmission and control solutions for industry, mobile machinery and renewable energy applications since 1956. Seit 1956 plant und realisiert Bonfiglioli innovative und zuverlässige Lösungen für die Leistungsüberwachung und -übertragung in industrieller Umgebung und für selbstfahrende Maschinen sowie Anlagen im Rahmen der erneuerbaren Energien. Depuis 1956, Bonfiglioli conçoit et réalise des solutions innovantes et fiables pour le contrôle et la transmission de puissance dans l’industrie et dans les machines automotrices et pour les énergies renouvelables. HEADQUARTERS Bonfiglioli Riduttori S.p.A. Via Giovanni XXIII, 7/A 40012 Lippo di Calderara di Reno Bologna (Italy)

 Open the catalog to page 1
Serie F - Shaft mounted gear units - Atex-3

INFORMAZIONI GENERALI GENERAL INFORMATION ALLGEMEINE INFORMATIONEN INFORMATIONS GENERALES Paragrafo Chapter Abschnitt Paragraphe Descrizione 1 Simbologia e unita di misura 2 Introduzione alle direttive ATEX 3 Coppia 14 Specifiche della vernice Pagina Page Seite Page Description Symbols and units of measure Introduction to the ATEX directives Torque Power Efficiency Gear ratio Angular velocity Moment of inertia Service factor Selection Verification Installation Conditions of supply Paint specifications Beschreibung Symbole und MaUeinheiten Beschreibung der ATEX-Zulassung Abtriebsmoment Leistung Wirkungsgrad Getriebeubersetzung Drehzahl Tragheitsmoment Betriebsfaktor Antriebsauswahl Prufungen Installation Lieferbedingungen Angaben...

 Open the catalog to page 3
Serie F - Shaft mounted gear units - Atex-4

1 - SIMBOLOGIA E UNITA 1 - SYMBOLS AND UNITS 1 - SYMBOLE UND 1 - SYMBOLES ET UNITES DI MISURA OF MEASURE MABEINHEITEN DE MESURE

 Open the catalog to page 4
Serie F - Shaft mounted gear units - Atex-5

Situazione di pericolo. Possono derivare danni alla salute e rischi per la sicurezza delle persone. Gefahr! Kann zu Beschädigungen und Risiken für Gesundheit und Sicherheit der Menschen. Situation de danger. peuvent causer des dommages et des risques pour la santé et la sécurité de personnes. Questo simbolo riporta i riferimenti angolari per l’indicazione della direzione del carico radiale (l’albero è visto di fronte). Danger. Can result in damage to the health and safety risks of the persons. This symbol refers to the angle the overhung load applies (viewing from drive end). Dieses Symbol gibt...

 Open the catalog to page 5
Serie F - Shaft mounted gear units - Atex-6

2 - INTRODUZIONE ALLE DIRETTIVE ATEX 2 - INTRODUCTION TO THE ATEX DIRECTIVES 2 - INTRODUCTION AUX DIRECTIVES ATEX Ai fini della direttiva 2014/34/UE si intende per atmosfera esplosiva quella costituita da una miscela: An explosive atmosphere for the purposes of Directive 2014/34/ EU is defined as a mixture: Im Sinne der Richtlinie 2014/34/EU ist eine explosionsfähige Atmosphäre definiert als ein Gemisch: D’après la directive 2014/34/UE, une atmosphère explosive est constituée par un mélange : a. di sostanze infiammabili allo stato di gas, vapori, nebbie o polveri; a. of flammable substances,...

 Open the catalog to page 6
Serie F - Shaft mounted gear units - Atex-7

|®| Zone/ Zones/ Atmosfera gassosa Gaseous atmosphere Gasformige Atmosph. Atmosphere gazeuse G I riduttori di produzione BONFI-GLIOLI RIDUTTORI selezionati dal presente catalogo sono ido-nei per installazione nelle zone 1, 21, 2 e 22. A partire dal 20 aprile 2016 la direttiva ATEX 2014/34/UE si ap-plica su tutto il territorio dell'Unio-ne Europea sostituendo le leggi divergenti attualmente in vigore a livello nazionale ed europeo in materia di atmosfera esplosiva e la precedente direttiva 94/9/CE. E da sottolineare che, per la pri-ma volta, le direttive si estendono anche agli apparecchi di natura meccanica,...

 Open the catalog to page 7
Serie F - Shaft mounted gear units - Atex-8

2.3 - LIVELLI DI PROTEZIONE PER LE VARIE CATEGORIE DI APPARECCHI Le varie categorie di apparec-chi devono essere in grado di funzionare conformemente ai parametri operativi stabiliti dal fabbricante, a determinati livelli di protezione. 2.3 - LEVELS OF PROTECTION FOR THE VARIOUS CATEGORIES OF EQUIPMENT The various categories of equipment must be able to operate in conformity witht he Manufacturer’s operational specifications, at certain defined levels of protection. 2.3 - SCHUTZGRADE FUR DIE VERSCHIEDENEN GERA-TEKATEGORIEN Die verschiedenen Gerateka-tegorien mussen gemaU der vom Betreiber festgesetzten Betriebsparameter...

 Open the catalog to page 8
Serie F - Shaft mounted gear units - Atex-9

2.4 - DEFINIZIONE DEI GRUPPI Gruppo I Comprende gli ap-parecchi destinati a essere uti-lizzati nei lavori in sotterraneo nelle miniere e nei loro impianti di superficie, esposti al rischio di sprigionamento di grisu e/o polveri combustibili. Gruppo II Comprende gli ap-parecchi destinati a essere uti-lizzati in altri ambienti in cui vi sono probability che si manife-stino atmosfere esplosive. E esclusa qualunque installa-zione di apparecchi BONFI-GLIOLI RIDUTTORI in appli-cazioni minerarie, classificabili come gruppo I e gruppo II, ca-tegoria 1. In sintesi, l'insieme di classifica-zioni degli...

 Open the catalog to page 9
Serie F - Shaft mounted gear units - Atex-10

Questo catalogo descrive i riduttori di produzione BONFIGLIOLI RIDUTTORI, destinati ad essere usati in ambienti con potenziale rischio di esplosione, limitatamente alle categorie 2 e 3. This catalogue describes BONFIGLIOLI RIDUTTORI gear units, intended for use in potentially explosive atmospheres, with limitation to categories 2 and 3. Dieser Katalog beschreibt die BONFIGLIOLI RIDUTTORI Getriebe, die für die Verwendung in explosionsgefährdeten Bereichen, nach Kategorie 2 und 3, vorgesehen sind. Ce catalogue décrit les réducteurs fabriqués par BONFIGLIOLI RIDUTTORI, et destinés à être utilisés...

 Open the catalog to page 10
Serie F - Shaft mounted gear units - Atex-11

3 - COPPIA Coppia nominate Mn2 [Nm] E la coppia trasmissibile in usci-ta con carico continuo uniforme, riferita alla velocita in ingresso ni e a quella corrispondente in uscita n2. E calcolata in base ad un fattore di servizio fs = 1. 3 - TORQUE Rated torque Mn2 [Nm] The torque that can be transmitted continuously through the output shaft, with the gear unit operated under a service factor fs = 1. Rating is speed sensitive. 3 - ABTRIEBSMOMENT Nenn-Drehmoment Mn2 [Nm] Dies ist das an der Abtriebswelle Ubertragbare Drehmoment bei gleichformiger Dauerbelastung bezogen auf die Antriebsdreh-zahl n1...

 Open the catalog to page 11

All Bonfiglioli catalogs and technical brochures

  1. HDP

    88  Pages

  2. Wind Solutions

    24  Pages

  3. 610X Series

    2  Pages

  4. 600Y3 Series

    2  Pages

  5. 600W series

    2  Pages

  6. Active Cube 7

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.