

Active Next Generation Operating Instruction Expansion Module EM-AUT-21 ANG210/ANG410/ANG510/ANG610
1 /
282Pages
Catalog excerpts

(§) Bonfiglioli Vectron Active Next Generation Operating Instruction Expansion Module EM-AUT-21 ANG210/ANG410/ANG510/ANG610
Open the catalog to page 1
7| Commissioning the encoder interface
Open the catalog to page 4
(§) Bonfiglioli Vectron
Open the catalog to page 5
1 General Information on Documentation 1.1 Instruction manuals For better clarity, the documentation is structured according to the customer-specific requirements for the frequency inverter. Quick start guide The Quick Start Guide describes the basic steps required for mechanical and electrical installation of the frequency inverter. The guided commissioning supports you in the selection of necessary parameters and the configuration of the frequency inverter by the software. Operating instructions The Operating Instructions describe all functions of the frequency inverter. The parameters...
Open the catalog to page 9
Software or Hardware designations and label names of the companies mentioned here are usually protected by law concerning trademark, patent and brand name. Licensing right and copyright are held by the respective companies. Contents of this document may not be copied or duplicated outside the legal regulations without written permission. 1.3 Warranty and liability BONFIGLIOLI VECTRON GmbH (hereinafter referred to as "manufacturer") notes that the contents of this document do not form part of any previous or existing agreement, assurance or legal relationship between the manufacturer and the...
Open the catalog to page 10
(§) Bonfiglioli Vectron 1.6 Storage The documentation forms an integral part of the frequency inverter. It must be stored such that it is accessible to operating staff at all times. In case the frequency inverter is sold to other users, this Operating Instructions document must also be handed over.
Open the catalog to page 11
2 General safety instructions and information on use The chapter "General safety instructions and information on use" contains general safety instructions for the Operator and the Operating Staff. At the beginning of certain main chapters, some safety instructions are included which apply to all work described in the relevant chapter. Special work-specific safety instructions are provided before each safety-relevant work step. 2.1 Terminology According to the documentation, different activities must be performed by certain persons with certain qualifications. The groups of persons with the...
Open the catalog to page 12
(§) Bonfiglioli Vectron 2.3 Misuse Any use other than that described in "Designated use" shall not be permissible and shall be considered as misuse. For example, the machine/plant must not be operated - by uninstructed staff, - while it is not in perfect condition, - without protection enclosure (e.g. covers), - without safety equipment or with safety equipment deactivated. The manufacturer shall not be held liable for any damage resulting from such misuse. The sole risk shall be borne by the operator. 2.3.1 Explosion protection The frequency inverter is an IP 20 protection class device....
Open the catalog to page 13
WARNING Identification of immediate threat holding a medium risk of death or serious injury if not avoided. CAUTION Identification of immediate threat holding a low risk of minor or moderate physical injury if not avoided. Identification of a threat holding a risk of material damage if not avoided.
Open the catalog to page 14
(§) Bonfiglioli Vectron 2.7 Directives and guidelines to be adhered to by the operator The operator must follow the following directives and regulations: • Ensure that the applicable workplace-related accident prevention regulations as well as other applicable national regulation are accessible to the staff. • An authorized person must ensure, before using the frequency inverter, that the device is used in compliance with its designated use and that all safety requirements are met. • Additionally, comply with the applicable laws, regulations and directives of the country in which the...
Open the catalog to page 15
2.9.2 General work safety • In addition to the Operating Instructions of the machine/plant, any applicable legal or other regulations relating to accident prevention and environmental protection must be complied with. The staff must be instructed accordingly. Such regulations and/or requirements may include, for example, handling of hazardous media and materials or provision/use of personal protective equipment. • In addition to these Operating Instructions, issue any additional directives that may be required to meet specific operating requirements, including supervision and reporting...
Open the catalog to page 16
(§) Bonfiglioli Vectron • When performing any work on/with the frequency inverter, always comply with the applicable national and international regulations/laws on work on electrical equipment/plants of the country in which the frequency inverter is used. • The cables connected to the frequency inverters may not be subjected to high-voltage insulation tests unless appropriate circuitry measures are taken before. • Only connect the frequency inverter to suitable supply mains. The frequency inverter may be operated in TN, TT and IT grid types. Precautions must be taken for operation in IT...
Open the catalog to page 17
Work on the electrical components may only be performed by a qualified electrician according to the applicable rules of electrical engineering. Only use original spare parts. Unauthorized opening and improper interventions in the machine/plant can lead to personal injury or material damage. Any repair work may only be carried out by the manufacturer or persons approved/licensed by the manufacturer. Any repair work must be carried out by qualified electricians. Check protective equipment regularly. Before performing any maintenance work, the machine/plant must be disconnected from mains...
Open the catalog to page 18
3 Technical data When using the EM-AUT extension modules, the technical data of the frequency inverter must be also considered. Control terminal X410A 1) The control electronics parameters can be configured as required. 2) The maximum power available is reduced by the other control outputs of the frequency inverter and extension module. 3) Also see chapter 13 Analog input/Analog output MF4 for more information Block diagram X410A I 1 I Resolver Ref + rn Resolver Ref -I 3 I Resolver Sin- / Encoder B+ I 4 I Resolver Sin+ / Encoder B-I 5 I Resolver Cos - / Encoder A+ I 6 I Resolver Cos + /...
Open the catalog to page 19All Bonfiglioli catalogs and technical brochures
-
Product Range Wind Solutions
28 Pages
-
Solution Condtruction Industry
52 Pages
-
Product Range Mobile Solution
44 Pages
-
Marine and Offshore
20 Pages
-
HDP
88 Pages
-
Worm Gear Series
86 Pages
-
V series Motovariator
362 Pages
-
Wind Solutions
24 Pages
-
Mechatronic Life Cycle
4 Pages
-
Bonfiglioli Digital Tools
12 Pages
-
Wind Solutions Product Range
28 Pages
-
Solutions for Water Treatment
16 Pages
-
Solutions for Packaging
16 Pages
-
Solutions for Food & Beverage
20 Pages
-
Spare parts list W Series
24 Pages
-
Drives for Road Machinery
36 Pages
-
Drives for Excavators
24 Pages
-
Mobile Solutions Product Range
44 Pages
-
Solutions for access platforms
16 Pages
-
Solutions for Mining
20 Pages
-
Solutions for Intralogistics
8 Pages
-
VF-W series - Wormgears IE2-IE3
298 Pages
-
VF-W series - Wormgears - Atex
46 Pages
-
VF-W series - Wormgears
268 Pages
-
Modular planetary gearboxes
560 Pages
-
600W2/3 Series
2 Pages
-
610X Series
2 Pages
-
Wheel drives - 600 Series
2 Pages
-
600Y3 Series
2 Pages
-
Widest Range of Final Drive
2 Pages
-
600W series
2 Pages
-
Active Cube 7
2 Pages
-
Power Drive VCB400
16 Pages
-
Advanced Standard Drive - Agile
52 Pages
-
Solution Drive - Active Series
72 Pages
-
BC - DC electric motors
20 Pages
-
3/H Combined gearboxes
20 Pages
-
RAN series - Mitre gears
28 Pages