Active Next Generation 210/410/510/610 Series Servo Drive Solutions
Open the catalog to page 1The highest level of precision, efficiency and energy optimization. With over 15 years of experience in creating dedicated motion control systems, Bonfiglioli has gained an enviable reputation in the world of industrial automation. Bonfiglioli offers its customers the highest possible level of precision, efficiency and energy optimization for their machines. Our solutions include low backlash planetary gearboxes, induction motors, servomotors and synchronous reluctance motors, open and closed loop inverters, servo inverters and regenerative inverters. A unique combination of mechatronic solutions...
Open the catalog to page 3Servo Drive Solutions
Open the catalog to page 4($□ Bonfiglioli 5 Bonfiglioli Active Next Generation: The drive designed for High Performance applications With the inverter series ANG Active Next Generation, Bonfiglioli expands its drive portfolio with a drive designed for providing machine builders high performance for standard and servo applications. The range includes: • 1 phase 230 V: 0.25...4 kW • 3 phase 230 V: 0.25...9.2 kW • 3 phase 400/480 V: 0.25...400...1200 kW • 3 phase 525 V: 160...400...1200 kW • 3 phase 690 V: 160...400...1200 kW Size 8 offers the opportunity as single device to power installations up to 400 kW and up to 1200...
Open the catalog to page 5Bonfiglioli drive power/control range Active Cube
Open the catalog to page 6Bonfiglioli system range ANG210/410/510/610 Active Next Generation BMD Permanent Magnet motor TQ/TQF, LC, MP, TR Low backlash gearboxes General purpose This catalogue concerns Active Next Generation series and Active Next Generation accessories. For information about the other products showed in above overview, please refer to relevant catalogues. High accuracy High dynamics BMS Precision Planetary Servo Gear Motor
Open the catalog to page 7Version A Standard C Coldplate L Liquid Cooling, stainless Steel, open cooling circuit M Liquid Cooling, Aluminium, closed cooling circuit Filter F Integrated EMI-filter - Without EMI-filter Mechanical Size 1 Frame Size 1 8 Frame Size 8
Open the catalog to page 8The order code of ANGx10 seriesANG 410 - 07 1 F A S B X S X 0 0 Reserved for future use IT Bridge* X Without IT Bridge W With IT Bridge (Standard) Safety S STO (Safe Torque Off) Communication ANG A EtherCAT D EtherCAT without Absolute Encoder J PROFINET R Ethernet/IP V Varan Coating B With Coating Brake Chopper X Without BC (size 6, 7 and 8 only) S BC included (standard) Version A Standard C Coldplate (Size 1 to 5) L Liquid Cooling, stainless Steel, open cooling circuit (Size 5 to 8) M Liquid Cooling, Aluminium, closed cooling circuit (Size 8) Filter F Integrated EMI-filter (blank)...
Open the catalog to page 9Hardware Mounting and Cooling • Standard Cabinet Mounting with Air Cooling (all mechanical sizes) • ColdPlate Mounting (mechanical sizes 1...5) • Liquid Cooling (mechanical sizes 5...8) • DIN Rail mounting (mechanical sizes 1 & 2) • Vibration resilient mounting kit for Air Cooling devices (mechanical sizes 1...6) Performance • Very high performance for speed, position and current control • Both “system drive” and “servo drive” focusing on applications where Ethernet-based communication and Absolute encoder is used at the same time • Optimized combination with Bonfiglioli BMD and BCR servomotor...
Open the catalog to page 10Software Flexibility • Control of asynchronous motors and synchronous motors (all without or with encoder feedback) • Preset values for Bonfiglioli motors to decrease commissioning times • Full set of operation modes, freely selectable: - Servo synchronous control with Resolver or Absolute encoder feedback - Field oriented (vector) control with Absolute encoder - Sensorless field oriented (vector) control for all suppoprted motor types • Flexible assignment of digital inputs and outputs to interface with software and hardware functions • “Motor chopper” function to increase braking power without...
Open the catalog to page 11Environment Operating conditions • 0°C - 40°C (40°C - 55°C with derating) • Pollution Degree 2 • Overvoltage Category III Environment class • Operation 3K3 (EN60721-3-3) • Relative humidity 15% ... 85%, no moisture condensation Altitude of installation • Up to 1000m (up to 4000 with derating) Storage conditions • According to EN50178 Protection degree (EN 60529) • IP20 with correctly mounted covers and connection terminals Environmental operation conditions according to DIN EN 60721-3-3: • 3Z1 (negligible thermal radiation) • 3B1 (no biological impact) • 3C1 (chemically active substances, limits...
Open the catalog to page 12Output, motor side (1) Notes: (1) Please check the Operating Instructions for additional data (2) Higher frequencies available on request (3) For more details, please check the Input filter table in this catalogue (4) Continous operation with rated current requires a line choke
Open the catalog to page 13Output, motor side (1) (1) Please check the Operating Instructions for additional data (2) Higher frequencies available on request (3) Continous operation with rated current requires a line choke
Open the catalog to page 14Size 1 (F, A or C) I Size 2 (F, A or C) Output, motor side (1) Notes: (1) Please check the Operating Instructions for additional data (2) Higher frequencies available on request (3) Continous operation with rated current requires a line choke (4) For more details, please check the Input filter table in this catalogue
Open the catalog to page 15Size 2 (F, A or C) I Size 3 (- or F, A or C) I Size 4 (-, A or C) Output, motor side (1) Notes: (1) Please check the Operating Instructions for additional data (2) Higher frequencies available on request (3) Continous operation with rated current requires a line choke
Open the catalog to page 16Output, motor side (1) Notes: (1) Please check the Operating Instructions for additional data (2) Higher frequencies available on request (3) Continous operation with rated current requires a line choke (4) When using Liquid Cooling devices, please check the Additional Operating Instructions for Liquid Cooling
Open the catalog to page 1728 Pages
16 Pages
52 Pages
44 Pages
20 Pages
88 Pages
86 Pages
362 Pages
44 Pages
24 Pages
4 Pages
12 Pages
28 Pages
16 Pages
20 Pages
24 Pages
36 Pages
24 Pages
16 Pages
20 Pages
8 Pages
298 Pages
46 Pages
268 Pages
560 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
16 Pages
52 Pages
72 Pages
20 Pages
20 Pages
28 Pages